Grzegorz Starobrat

Dr. Grzegorz Starobrat

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Anna DanielewiczAnna Danielewicz
Anna Danielewicz
MFMarek Fatyga
Marek Fatyga
GSGrzegorz Starobrat
Grzegorz Starobrat
MRMonika Różańska-Boczula
Monika Różańska-Boczula
MWMagdalena Wójciak
Magdalena Wójciak
Michał LatalskiMichał Latalski
Michał Latalski
Spinal deformity corrections in paediatric patients are long-lasting procedures involving damage to many tissues and long pain exposure; therefore, effective pain management after surgical treatment is an important issue. In this study, the effect of inclusion of local infiltration analgesia, as an integral part of the scheme in postoperative pain control, in children and adolescents, subjected to the spinal deformity correction procedure, was assessed. Thirty patients, aged 8 to 17 years, undergoing spinal deformity correction were divided into a study group, receiving a 0.25% bupivacaine solution before wound closure, and a control group (no local analgesic agent). Morphine, at the doses of 0.10 mg/kg of body weight, was administered to the patients when pain occurred. Pain scores, morphine administration, and bleeding were observed during 48 postoperative hours. The pain scores were slightly lower in a 0–4 h period in patients who received bupivacaine compared with those in the control group. However, no differences were observed in a longer period of time and in the total opioid consumption. Moreover, increasing bleeding was observed in the bupivacaine-treated patients (study group) vs. the control. Bupivacaine only modestly affects analgesia and, due to the increased bleeding observed, it should not to be part of pain control management in young patients after spinal deformity correction.

15 December 2021 in Animals
Verified
Journal Article
Open access
PDF file
JZJoanna Zdziennicka
Joanna Zdziennicka
JWJoanna Wessely-Szponder
Joanna Wessely-Szponder
GSGrzegorz Starobrat
Grzegorz Starobrat
AJAndrzej Junkuszew
Andrzej Junkuszew
Titanium (Ti) is currently the most common biomaterial used for orthopedic implants; however, these implants may cause deleterious immune response. To investigate the possible mechanisms involved in excessive inflammation, we assessed the activity of neutrophils and monocyte-derived macrophages (MDMs) during the insertion of the Ti implant in a sheep model. The study was conducted on 12 sheep, 4 of which were control animals and 8 were in the experimental group with inserted Ti implant. Neutrophil secretory response was estimated at two time points T0 before surgery and T1 1 h after implantation and was based on the release of enzymes from neutrophil granules and reactive oxygen and nitrogen species (RONS) generation. MDM function was evaluated 5 months after implantation, on the basis of RONS generation arginase activity and morphological changes. Moreover, the influence of some autologous neutrophil derived products, namely, antimicrobial neutrophil extract (ANE) and neutrophil degranulation products (DGP) on leukocytes was estimated. Our study revealed that Ti implant insertion did not cause any adverse effects up to 5 months after surgical procedure. Stimulation of neutrophil cultures with ANE decreased the enzyme release as well as superoxide generation. Treatment of MDM with ANE diminished superoxide and NO generation and increased arginase activity. On the other hand, MDM stimulated with DGP showed elevated superoxide and NO generation as well as decreased arginase activity. To summarize, ANE exerted an anti-inflammatory and pro-resolving effect on studied leukocytes, whereas DGP acted as pro-inflammatory.

Verified
Journal Article
Open access
PDF file
Michał LatalskiMichał Latalski
Michał Latalski
MLMichał Latalski
Michał Latalski
GSGrzegorz Starobrat
Grzegorz Starobrat
EWEdward Warda
Edward Warda
MWMagdalena Wójciak
Magdalena Wójciak
ISIreneusz Sowa
Ireneusz Sowa
Flexible spine tethering is a relatively novel fusionless surgical technique that aims to correct scoliosis based on growth modulation due to the pressure exerted on the vertebral body epiphyseal growth plate. The correction occurs in two phases: immediate intraoperative and postoperative with growth. The aim of this study was to evaluate the reactivation of vertebral growth plate function after applying corrective forces. The rat tail model was used. Asymmetric compression and distraction of caudal growth plates were performed using a modified external fixation apparatus. Radiological and histopathological data were analysed. After three weeks of correction, the activity of the structures increased across the entire growth plate width, and the plate was thickened. The height of the hypertrophic layer and chondrocytes on the concave side doubled in height. The height of chondrocytes and the cartilage thickness on the concave and central sides after the correction did not differ statistically significantly from the control group. Initiation of the correction of scoliosis in the growing spine, with relief of the pressure on the growth plate, allows the return of the physiological activity of the growth cartilage and restoration of the deformed vertebral body.