Victoria Shpacovitch

Dr. Victoria Shpacovitch

Biomedical Research Department, Bioresponsive Materials Working Group, Leibniz Institute for Analytical Sciences, ISAS e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Victoria ShpacovitchVictoria Shpacovitch
Victoria Shpacovitch
Roland  Hergenröder Roland Hergenröder
Roland Hergenröder
Surface plasmon resonance (SPR), as a physical phenomenon, is not restricted only to events occurring in thin planar metal films

1 October 2015 in Analytical Biochemistry
Verified
Journal Article
Closed access
Victoria ShpacovitchVictoria Shpacovitch
Victoria Shpacovitch
VTVladimir Temchura
Vladimir Temchura
MMMikhail Matrosovich
Mikhail Matrosovich
JHJoachim Hamacher
Joachim Hamacher
JSJulia Skolnik
Julia Skolnik
AZAlexander Zybin
Alexander Zybin

1 April 2018 in Analytica Chimica Acta
Verified
Journal Article
Closed access
Victoria ShpacovitchVictoria Shpacovitch
Victoria Shpacovitch
RHRoland Hergenröder
Roland Hergenröder

27 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Victoria ShpacovitchVictoria Shpacovitch
Victoria Shpacovitch
ISIrina Sidorenko
Irina Sidorenko
JLJan Eric Lenssen
Jan Eric Lenssen
VTVladimir Temchura
Vladimir Temchura
FWFrank Weichert
Frank Weichert
Roland  Hergenröder Roland Hergenröder
Roland Hergenröder
The PAMONO-sensor (plasmon assisted microscopy of nano-objects) demonstrated an ability to detect and quantify individual viruses and virus-like particles. However, another group of biological vesicles—microvesicles (100–1000 nm)—also attracts growing interest as biomarkers of different pathologies and needs development of novel techniques for characterization. This work shows the applicability of a PAMONO-sensor for selective detection of microvesicles in aquatic samples. The sensor permits comparison of relative concentrations of microvesicles between samples. We also study a possibility of repeated use of a sensor chip after elution of the microvesicle capturing layer. Moreover, we improve the detection features of the PAMONO-sensor. The detection process utilizes novel machine learning techniques on the sensor image data to estimate particle size distributions of nano-particles in polydisperse samples. Altogether, our findings expand analytical features and the application field of the PAMONO-sensor. They can also serve for a maturation of diagnostic tools based on the PAMONO-sensor platform.

19 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZUZohair Usfoor
Zohair Usfoor
KKKatharina Kaufmann
Katharina Kaufmann
ARAl Shahriar Hossain Rakib
Al Shahriar Hossain Rakib
Roland  Hergenröder Roland Hergenröder
Roland Hergenröder
Victoria ShpacovitchVictoria Shpacovitch
Victoria Shpacovitch
Nanoparticle Tracking Analysis (NTA) allows for the simultaneous determination of both size and concentration of nanoparticles in a sample. This study investigates the accuracy of particle size and concentration measurements performed on an LM10 device. For experiments, standard nanoparticles of different sizes composed of two materials with different refractive indices were used. Particle size measurements were found to have a decent degree of accuracy. This fact was verified by the manufacturer-reported particle size—determined by transmission electron microscopy (TEM)—as well as by performed scanning electron microscopy (SEM) measurements. On the other hand, concentration measurements resulted in overestimation of the particle concentration in majority of cases. Thus, our findings confirmed the accuracy of nanoparticle sizing performed by the LM10 instrument and highlighted the overestimation of particle concentration made by this device. In addition, an approach of swift correction of the results of concentration measurements received for samples is suggested in the presented study.

3 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
QBQais Al Bataineh
Qais Al Bataineh
Victoria ShpacovitchVictoria Shpacovitch
Victoria Shpacovitch
DSDiyar Sadiq
Diyar Sadiq
ATAhmad Telfah
Ahmad Telfah
Roland  Hergenröder Roland Hergenröder
Roland Hergenröder
Complex composite films based on polyaniline (PANI) doped hydrochloric acid (HCl) incorporated with aluminum nitrate (Al(NO3)3) on Au-layer were designed and synthesized as a surface plasmon resonance (SPR) sensing device. The physicochemical properties of (PANI-HCl)/Al(NO3)3 complex composite films were studied for various Al(NO3)3 concentrations (0, 2, 4, 8, 16, and 32 wt.%). The refractive index of the (PANI-HCl)/Al(NO3)3 complex composite films increased continuously as Al(NO3)3 concentrations increased. The electrical conductivity values increased from 5.10 µS/cm to 10.00 µS/cm as Al(NO3)3 concentration increased to 32 wt.%. The sensitivity of the SPR sensing device was investigated using a theoretical approach and experimental measurements. The theoretical system of SPR measurement confirmed that increasing Al(NO3)3 in (PANI-HCl)/Al(NO3)3 complex composite films enhanced the sensitivity from about 114.5 [Deg/RIU] for Au-layer to 159.0 [Deg/RIU] for Au-((PANI-HCl)/Al(NO3)3 (32 wt.%)). In addition, the signal-to-noise ratio for Au-layer was 3.95, which increased after coating by (PANI-HCl)/Al(NO3)3 (32 wt.%) complex composite layer to 8.82. Finally, we conclude that coating Au-layer by (PANI-HCl)/Al(NO3)3 complex composite films enhances the sensitivity of the SPR sensing device.