Torsten Pastor

Dr. Torsten Pastor

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2021 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
LELukas Ernstbrunner
Lukas Ernstbrunner
TPTorsten Pastor
Torsten Pastor
MWManuel Waltenspül
Manuel Waltenspül
CGChristian Gerber
Christian Gerber
KWKarl Wieser
Karl Wieser
The Latarjet is a successful procedure but can be associated with significant complications, including failure. Iliac crest bone grafting (ICBG) is one of the salvage options for such failure. To analyze factors associated with failure or success to restore shoulder stability with ICBG after Latarjet failure. Case series; Level of evidence, 4. Twenty consecutive patients with recurrence of instability after a Latarjet procedure underwent revision using ICBG. Sixteen patients (80%) with a mean age of 35.0 years (range, 25-55) could be personally reexamined clinically and radiographically (including computed tomography scan) after a mean follow-up of 4.5 years (range, 2-8). Twelve patients had redislocation and 4 had recurrent subluxation after the Latarjet. Salvage ICBG failed in 7 patients because of recurrent dislocations, with 5 necessitating reoperations: 2 arthrodeses, 1 reverse total shoulder arthroplasty, 1 repeat ICBG, and 1 Hill-Sachs allograft reconstruction and Bankart repair. Factors associated with ICBG failure were multidirectional instability (n = 2), subscapularis insufficiency (n = 1), uncontrolled seizures (n = 1), static inferior glenohumeral subluxation (n = 1), total graft resorption (n = 1), and voluntary dislocation attributed to schizoaffective disorder (n = 1). The initial Latarjet graft was malpositioned (too medial) in 3 of these patients. In patients without recurrent instability (n = 9), reasons for Latarjet failure were graft related: 6 graft avulsions, 2 graft resorptions, and 1 medial graft malpositioning. The mean absolute Constant score (62 to 87 points, P = .012) and relative Constant score (66% to 91%, P = .012), pain (10 to 15 points, P < .001), and Subjective Shoulder Value (31% to 85%, P = .011) in the group with a successful procedure were significantly improved over the preoperative state, and the total Western Ontario Shoulder Instability Index averaged 64% at final follow-up. Except in 1 case of major resorption, mild graft resorption or none was observed in successful procedures. Axial and sagittal graft positioning was good in all 9 patients. Salvage ICBG for failed Latarjet procedures failed in 7 of 16 patients. It was successful in patients with clearly graft-related factors of the initial Latarjet procedure. However, patients with unclear instability symptoms, subscapularis insufficiency, inferior subluxation, uncontrolled seizures, or psychological disorders were poor candidates for salvage ICBG, underlining the importance of careful patient selection for the initial Latarjet procedure and for salvage ICBG.

30 May 2022 in Medicina
Verified
Journal Article
Open access
PDF file
TPTatjana Pastor
Tatjana Pastor
LNLadislav Nagy
Ladislav Nagy
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl
SRSimon Roner
Simon Roner
TPTorsten Pastor
Torsten Pastor
ASAndreas Schweizer
Andreas Schweizer
Background and Objectives: Three-dimensional planning and guided osteotomy utilizing patient-specific instrumentation (PSI) with the contralateral side used as a reference have been proven as effective in the treatment of malunions following complex fractures of the distal radius. However, this approach has not yet been described in relation to fracture reduction of the distal radius. The aim of this study was to assess the technical and logistical feasibility of computer-assisted surgery in a clinical setting using PSI for fracture reduction and fixation. Materials and Methods: Five patients with varied fracture patterns of the distal radius underwent operative treatment with using PSI. The first applied PSI guide allowed specific and accurate placement of Kirschner wires inside the multiple fragments, with subsequent concurrent reduction using a second guide. Results: Planning, printing of the guides, and operations were performed within 5.6 days on average (range of 1–10 days). All patients could be treated within a reasonable period of time, demonstrating good outcomes, and were able to return to work after a follow-up of three months. Mean wrist movements (°) were 58 (standard deviation (SD) 21) in flexion, 62 (SD 15) in extension, 73 (SD 4) in pronation and 74 (SD 10) in supination at a minimum follow-up of 6 months. Conclusions: Three-dimensional planned osteosynthesis using PSI for treatment of distal radius fractures is feasible and facilitates reduction of multiple fracture fragments. However, higher costs must be taken into consideration for this treatment.

8 November 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
TPTorsten Pastor
Torsten Pastor
IZIvan Zderic
Ivan Zderic
DGDominic Gehweiler
Dominic Gehweiler
MGMichael J. Gardner
Michael J. Gardner
KSKarl Stoffel
Karl Stoffel
BGBoyko Gueorguiev
Boyko Gueorguiev

28 March 2022 in Clinical Biomechanics
Verified
Journal Article
Closed access
TPTorsten Pastor
Torsten Pastor
MKMatthias Knobe
Matthias Knobe
BWBryan J.M. van de Wall
Bryan J.M. van de Wall
IRIngmar F. Rompen
Ingmar F. Rompen
IZIvan Zderic
Ivan Zderic
FBFrank J.P. Beeres
Frank J.P. Beeres

23 February 2023 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
TPTorsten Pastor
Torsten Pastor
IZIvan Zderic
Ivan Zderic
KKKenneth P. van Knegsel
Kenneth P. van Knegsel
FBFrank J. P. Beeres
Frank J. P. Beeres
FMFilippo Migliorini
Filippo Migliorini
MKMatthias Knobe
Matthias Knobe

17 April 2022 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
PDF file
FSFiras Souleiman
Firas Souleiman
IZIvan Zderic
Ivan Zderic
TPTorsten Pastor
Torsten Pastor
PVPeter Varga
Peter Varga
THTobias Helfen
Tobias Helfen
PHP. Hepp
P. Hepp
Purpose: Glenohumeral joint injuries frequently result in shoulder instability. However, the biomechanical effect of cartilage loss on shoulder stability remains unknown. The aim of the current study was to investigate biomechanically the effect of two severity stages of cartilage loss in different dislocation directions on shoulder stability.Methods: Joint dislocation was provoked in 11 human cadaveric glenoids for 7 different directions between 3 o'clock (anterior) and 9 o'clock (posterior). Shoulder stability ratio (SSR) and concavity gradient were assessed in three states: intact, 3 mm and 6 mm simulated cartilage loss. The influence of cartilage loss on SSR and concavity gradient was statistically evaluated.Results: Both SSR and concavity gradient decreased significantly between intact state and 6 mm cartilage loss in every dislocation direction (p ≤ 0.038), except concavity gradient in 4 o'clock direction. Thereby, anterior–inferior dislocation directions were associated with the highest decrease in both SSR and concavity gradient of up to 59.0% and 49.4%, respectively, being significantly bigger for SSR compared with all other dislocation directions (p ≤ 0.040). Correlations between concavity gradient and SSR for pooled dislocation directions were significant in each separate specimen's state (p < 0.001).Conclusion: From a biomechanical perspective, articular cartilage of the glenoid contributes significantly to the concavity gradient, correlating strongly with the associated loss in glenohumeral joint stability. The biggest effect of cartilage loss is observed in the most frequently occurring anterior–inferior dislocation directions, suggesting that surgical interventions to restore cartilage's surface and concavity should be considered for recurrent shoulder dislocations in presence of cartilage loss.