Amir Shaaban Farag Mohamed Nawar

Dr. Amir Shaaban Farag Mohamed Nawar

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2026 in Analytica
Verified
Journal Article
Open access
PDF file
FMFotouh Rashed Mansour
Fotouh Rashed Mansour
Marcello LocatelliMarcello Locatelli
Marcello Locatelli
ROReem Hasan Obaydo
Reem Hasan Obaydo
ANAmir Shaaban Farag Mohamed Nawar
Amir Shaaban Farag Mohamed Nawar
ABalaa mostafa bedair
alaa mostafa bedair
White Analytical Chemistry (WAC) provides a holistic framework for evaluating analytical methods by balancing analytical performance, environmental sustainability, and practical efficiency. Existing WAC assessment tools offer structured evaluation but often lack flexibility or comprehensiveness. To bridge this gap, we introduce the Whiteness Evaluation for Chemical Analysis (WECA) tool as a dynamic, web-based application that enables customizable, context-aware assessment of analytical methods. WECA allows users to select 2–4 criteria per RGB domain (Red: analytical performance; Green: environmental impact; Blue: practical efficiency), assign user-defined weights, and visualize results through an intuitive color-coded interface. The tool calculates a composite WECA score (%) that reflects overall method “whiteness”. Three case studies, covering HPLC-DAD, micellar electrokinetic chromatography, and electrochemical sensing, demonstrate WECA’s applicability and its ability to highlight method strengths and weaknesses across diverse analytical scenarios. WECA represents a step toward more adaptable, transparent, and visually intuitive method evaluation in alignment with the evolving principles of WAC.

9 July 2022 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
ANAmir Shaaban Farag Mohamed Nawar
Amir Shaaban Farag Mohamed Nawar
A completely new direct voltammetric method has been developed for determination of acetaminophen (APAP), known as popular analgesic drug. The present electroanalytical method is based on anodic oxidation of APAP at the glassy carbon paste electrode modified with reduced graphene oxide (RGO). Key experimental conditions were studied, resulting in a set of optimal conditions: acetate buffer (pH 5.0) as working medium electrolyte, content of RGO, parameters of squarewave voltammetry including the potential step of 5 mV, potential amplitude of 50 mV, and frequency of 40 Hz. If peak area is used for evaluation, a linear range from 1.2 × 10–6to 2.2 × 10–4 mol L−1characterized by determination coefficient of 0.9971, limits of quantification and detection, 9.3 × 10–7 mol L−1and 3.1 × 10–7 mol L−1, respectively, will be obtained. Under validation, the precision was described by relative standard deviation of 2.9% for the model sample analysis. Finally, the developed voltammetric method was compared with a reference high-performance liquid chromatography method in the analysis of commercially available pharmaceutical preparation and human urine collected from five healthy volunteers.Graphical abstract

2 September 2024 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
ANAmir Shaaban Farag Mohamed Nawar
Amir Shaaban Farag Mohamed Nawar
MRMohamed Rizk
Mohamed Rizk
OMOmaima Mahmoud Mohamed
Omaima Mahmoud Mohamed
MAMarwa Mohamed Azab
Marwa Mohamed Azab
In this study, a new, rapid, simple, and cost-effective fluorescent probe based on carbon dots (CDs) has been developed for the selective determination of nitrazepam (NZP). The CDs were synthesized with high production yield (71.43%) through one step carbonization of dried banana peels. The fluorescence intensity of the CDs is quenched by increasing the NZP concentration as a result of the inner-filter effect and dynamic quenching mechanism. This fluorescent sensor effectively quantified NZP in the linear range of 0.30–26 μg mL−1, with a limit of detection of 0.10 μg mL−1. The performance of the sensor was validated according to ICH guidelines and exhibited high precision and accuracy. The proposed method was also successfully extended for determining NZP in tablet dosage form and milk samples.

6 August 2024 in Electroanalysis
Verified
Journal Article
Closed access
MAMarwa M. Azab
Marwa M. Azab
MRMohamed Rizk
Mohamed Rizk
OMOmaima M. Mohamed
Omaima M. Mohamed
ANAmir Shaaban Farag Mohamed Nawar
Amir Shaaban Farag Mohamed Nawar

22 March 2026 in Electroanalysis
Verified
Journal Article
Closed access
DMDina A. Mohamed
Dina A. Mohamed
ANAmir Shaaban Farag Mohamed Nawar
Amir Shaaban Farag Mohamed Nawar
MEMaha M. Abou El‐Alamin
Maha M. Abou El‐Alamin
EKElmorsy Khaled
Elmorsy Khaled
ARAbdellatef A. Radowan
Abdellatef A. Radowan