Behdad Arandian

Prof. Behdad Arandian

Islamic Azad University Dolatabad, Dowlatābād, Iran
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Behdad ArandianBehdad Arandian
Behdad Arandian
RHRahmat-Allah Hooshmand
Rahmat-Allah Hooshmand
EGEskandar Gholipour
Eskandar Gholipour

22 March 2022 in IEEE Access
Verified
Journal Article
Open access
Behdad ArandianBehdad Arandian
Behdad Arandian
mahdiyeh Eslamimahdiyeh Eslami
mahdiyeh Eslami
SKSaifulnizam Abd. Khalid
Saifulnizam Abd. Khalid
Baseem KhanBaseem Khan
Baseem Khan
USUsman Ullah Sheikh
Usman Ullah Sheikh
Adil Hussein MohammedAdil Hussein Mohammed
Adil Hussein Mohammed
Renewable energy is becoming more popular due to environmental concerns about the previous energy source. Accurate solar photovoltaic (PV) system model parameters substantially impact the efficiency of solar energy conversion to electricity. In this matter, swarm and evolutionary optimization algorithms have been widely utilized in dealing with practical problems due to their more straightforward concepts, efficacy, flexibility, and easy-to-implement procedural frameworks. However, the nonlinearity and complexity of the PV parameter identification caused swarm and evolutionary optimizers to exhibit Immaturity in the obtained solutions. In this study, an effective metaheuristic algorithm based on tunicate swarm optimization (TSA) is proposed for parameter identification of PV models. The proposed improved algorithm (ITSA) has two main phases at each iteration: searching all around the search space based on a randomly selected tunicate and improving the search using the position of the best tunicate. This modification improves the algorithm’s exploration ability while also preventing premature convergence. The suggested algorithm’s performance is confirmed using ten mathematical test functions and the outcomes are compared with TSA as well as some effective optimization algorithms. The proposed ITSA optimally identifies various parameters in the PV model, such as single diode (SDM), double diode (DDM), and PV modules. Based on the comprehensive comparisons, results indicate that the improved ITSA algorithm has higher convergence accuracy and better stability than the original TSA and other studied algorithms.


5 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
AFArash Mohammadi Fallah
Arash Mohammadi Fallah
EGEhsan Ghafourian
Ehsan Ghafourian
LSLadan Shahzamani Sichani
Ladan Shahzamani Sichani
HGHossein Ghafourian
Hossein Ghafourian
Behdad ArandianBehdad Arandian
Behdad Arandian
Moncef L. NehdiMoncef L. Nehdi
Moncef L. Nehdi
Proper analysis of building energy performance requires selecting appropriate models for handling complicated calculations. Machine learning has recently emerged as a promising effective solution for solving this problem. The present study proposes a novel integrative machine learning model for predicting two energy parameters of residential buildings, namely annual thermal energy demand (DThE) and annual weighted average discomfort degree-hours (HDD). The model is a feed-forward neural network (FFNN) that is optimized via the electrostatic discharge algorithm (ESDA) for analyzing the building characteristics and finding their optimal contribution to the DThE and HDD. According to the results, the proposed algorithm is an effective double-target model that can predict the required parameters with superior accuracy. Moreover, to further verify the efficiency of the ESDA, this algorithm was compared with three similar optimization techniques, namely atom search optimization (ASO), future search algorithm (FSA), and satin bowerbird optimization (SBO). Considering the Pearson correlation indices 0.995 and 0.997 (for the DThE and HDD, respectively) obtained for the ESDA-FFNN versus 0.992 and 0.938 for ASO-FFNN, 0.926 and 0.895 for FSA-FFNN, and 0.994 and 0.995 for SBO-FFNN, the ESDA provided higher accuracy of training. Subsequently, by collecting the weights and biases of the optimized FFNN, two formulas were developed for easier computation of the DThE and HDD in new cases. It is posited that building engineers and energy experts could consider the use of ESDA-FFNN along with the proposed new formulas for investigating the energy performance in residential buildings.
1

31 January 2022 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
ATAli Toolabi
Ali Toolabi
MAMorteza Aghahadi
Morteza Aghahadi
mahdiyeh Eslamimahdiyeh Eslami
mahdiyeh Eslami
SRShima Rashidi
Shima Rashidi
Behdad ArandianBehdad Arandian
Behdad Arandian
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
This paper presents a new approach for the coordinated design of a power system stabilizer- (PSS-) and static VAR compensator- (SVC-) based stabilizer. For this purpose, the design problem is considered as an optimization problem, while the decision variables are the controllers’ parameters. This paper proposes an effective optimization algorithm based on a rat swarm optimizer, namely, adaptive rat swarm optimization (ARSO), for solving complex optimization problems as well as coordinated design of controllers. In the proposed ARSO, instead of a random initial population, the algorithm starts the search process with fitter solutions using the concept of the opposite number. In addition, in each iteration of the optimization, the new algorithm replaces the worst solution with its opposite or a random part of the best solution to avoid getting trapped in local optima and increase the global search ability of the algorithm. The performance of the new ARSO is investigated using a set of benchmark test functions, and the results are compared with those of the standard RSO and some other methods from the literature. In addition, a case study from the literature is considered to evaluate the efficiency of the proposed ARSO for coordinated design of controllers in a power system. PSSs and additional SVC controllers are being considered to demonstrate the feasibility of the new technique. The numerical investigations show that the new approach may provide better optimal damping and outperform previous methods.

14 September 2021 in IET Communications
Verified
Journal Article
Open access
PDF file
MHMasoud Hashemi
Masoud Hashemi
Danial JavaheriDanial Javaheri
Danial Javaheri
Parisa SabbaghParisa Sabbagh
Parisa Sabbagh
Behdad ArandianBehdad Arandian
Behdad Arandian
KAKarlo Abnoosian
Karlo Abnoosian
Cloud computing is a rapidly evolving computational technology. It is a distributed computational system that offers dynamically scaled computational resources, such as processing power, storage, and applications, delivered as a service through the Internet. Virtual machines (VMs) allocation is known as one of the most significant problems in cloud computing. It aims to find a suitable location for VMs on physical machines (PMs) to attain predefined aims. So, the main purpose is to reduce energy consumption and improve resource utilization. Because the VM allocation issue is NP‐hard, meta‐heuristic and heuristic methods are frequently utilized to address it. This paper presents an energy‐aware VM allocation method using the improved grey wolf optimization (IGWO) algorithm. Our key goals are to decrease both energy consumption and allocation time. The simulation outcomes from the MATLAB simulator approve the excellence of the algorithm compared to previous works.