Wei Yu

Prof. Dr. Wei Yu

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
WYWei Yu
Wei Yu
CWChengxiang Wang
Chengxiang Wang
MHMin Huang
Min Huang
Accurate images reconstructed from limited computed tomography (CT) data are desired when reducing the X-ray radiation exposure imposed on patients. The total variation (TV), known as the l1-norm of the image gradient magnitudes, is popular in CT reconstruction from incomplete projection data. However, as the projection data collected are from a sparse-view of the limited scanning angular range, the results reconstructed by a TV-based method suffer from blocky artifact and gradual changed artifacts near the edges, which in turn make the reconstruction images degraded. Different from the TV, the ℓ0 -norm of an image gradient counts the number of its non-zero coefficients of the image gradient. Since the regularization based on the ℓ0 -norm of the image gradient will not penalize the large gradient magnitudes, the edge can be effectively retained. In this work, an edge-preserving image reconstruction method based on l0-regularized gradient prior was investigated for limited-angle computed tomography from sparse projections. To solve the optimization model effectively, the variable splitting and the alternating direction method (ADM) were utilized. Experiments demonstrated that the ADM-like method used for the non-convex optimization problem has better performance than other classical iterative reconstruction algorithms in terms of edge preservation and artifact reduction.

8 October 2022 in Process Safety and Environmental Protection
Verified
Journal Article
Closed access
WYWei Yu
Wei Yu
CLChao Liu
Chao Liu
Qibin LiQibin Li
Qibin Li
LXLiyong Xin
Liyong Xin
SWShukun Wang
Shukun Wang

28 November 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
WYWei Yu
Wei Yu
CWChengxiang Wang
Chengxiang Wang
XNXiaoying Nie
Xiaoying Nie
DZDehui Zeng
Dehui Zeng
Iterative reconstruction (IR) methods that can incorporate filtering or regularization techniques have received widespread attention in many situations. Total variation (TV) regularization has proven to be a powerful tool to suppress streak artifacts and noise for sparse-view computed tomography (CT) reconstruction over 360°. However, with under-sampled projection data from limited-view (e.g. half-view) CT scanning, where the projections are further reduced, the edge structures are partly blurred, and some artifacts (such as blocky artifacts) are not effectively suppressed in TV-based results. To further improve the quality of the reconstructed image, a sparsity-induced dynamic guided image filtering reconstruction (SIDGIFR) method is proposed. Intermediate reconstruction results constrained by total difference (TD) minimization are taken as the guidance image to filter the results of projection onto convex sets (POCS) by guided image filtering (GIF). In the SIDGIFR algorithm, the guidance image is dynamically updated, which can transfer the important features (such as edge and small details) to the filtered image during the iterative process. To confirm the efficiency and feasibility of the SIDGIFR algorithm, simulated experiments and real data studies are performed. The quantitative evaluation shows that the proposed SIDGIFR method has better performance than other classical IR methods. What’s more, the proposed SIDGIFR algorithm can better preserve the edge structures, and suppress noise and artifacts, than the existing IR methods.

1 January 2018 in Inverse Problems and Imaging
Verified
Journal Article
Open access
PDF file
CWChengxiang Wang
Chengxiang Wang
LZLi Zeng
Li Zeng
WYWei Yu
Wei Yu
LXLiwei Xu
Liwei Xu
In some practical applications of computed tomography (CT) imaging, the projections of an object are obtained within a limited-angle range due to the restriction of the scanning environment. In this situation, conventional analytic algorithms, such as filtered backprojection (FBP), will not work because the projections are incomplete. An image reconstruction algorithm based on total variation minimization (TVM) can significantly reduce streak artifacts in sparse-view reconstruction, but it will not effectively suppress slope artifacts when dealing with limited-angle reconstruction problems. To solve this problem, we consider a family of image reconstruction model based on $\ell_{0}$ and $\ell_{2}$ regularizations for limited-angle CT and prove the existence of a solution for two CT reconstruction models. The Alternating Direction Method of Multipliers (ADMM)-like method is utilized to solve our model. Furthermore, we prove the convergence of our algorithm under certain conditions. Some numerical experiments are used to evaluate the performance of our algorithm and the results indicate that our algorithm has advantage in suppressing slope artifacts.

23 March 2018 in Journal of Inverse and Ill-posed Problems
Verified
Journal Article
Closed access
PDF file
CWChengxiang Wang
Chengxiang Wang
LZLi Zeng
Li Zeng
LZLingli Zhang
Lingli Zhang
YGYumeng Guo
Yumeng Guo
WYWei Yu
Wei Yu
The limited-angle computed tomography (CT) reconstruction problem is an ill-posed inverse problem, and the parameter selection for limited-angle CT iteration reconstruction is a difficult issue in practical application. In this paper, to alleviate the instability of limited-angle CT reconstruction problem and automatize the reconstruction process, we propose an adaptive iteration reconstruction method that the regularization parameter is chosen adaptively via the plot of the normalized wavelet coefficients fitting residual versus that the ℓ 0 {\ell_{0}} regularization part. The experimental results show that the reconstructed images using the method with adapted regularization parameter are almost as good as that using the non-adapted parameter method in terms of visual inspection, in addition, our method has an advantage in adaptively choosing the regularization parameter.

13 August 2020 in IEEE Access
Verified
Journal Article
Open access
ZSZhaoqiang Shen
Zhaoqiang Shen
CGChangcheng Gong
Changcheng Gong
WYWei Yu
Wei Yu
LZLi Zeng
Li Zeng
For limited-angle computed tomography (CT) image reconstruction, the classical total variation (TV) based algorithms suffer from the limited-angle artifacts, because TV only used the gradient information of the image. The priori image constrained compressed sensing (PICCS) based reconstruction algorithms can reduce the limited-angle artifacts by using a priori image consistent with the target image. However, it is difficult to ensure the consistency of priori image and target image in practice. In order to reconstruct high quality image when the prior image is inconsistent with the target image, we proposed a guided image filter reconstruction based on TV and prior image (TVPI-G). In each iteration phase, our algorithm first performs a TV step (include simultaneous algebra reconstruction technique (SART) and TV) to get initiatory reconstruction image; Then, the results of TV iteration are combined with prior images to form an intermediate result; Finally, we use the guided image filter to modify the intermediate results with the TV result as the guide image. Numerical reconstruction results on simulation phantom with different intensities Poisson noise illustrates that our proposed TVPI-G algorithm is better than other comparison algorithms in both qualitative and quantitative aspects, including TV, PICCS, and SART guided image filtering.