Limited-angle CT reconstruction problem is an ill-posed inverse problem. Currently, regularized CT reconstructions are usually considered by incorporating the total variation (TV) norm of an image into data fidelity term. However, the reconstructed images may be degraded using the TV-based minimization method with limited-angle artifacts. In recent years, the theory of wavelet tight frame has been well developed and has some advantages in preserving the sharp features as well as smoothness. To further improve the quality of reconstructed images, we propose an image reconstruction method incorporating TV with wavelet tight frame for limited-angle CT problem, which objective function includes ℓ1 and ℓ0 regularization terms and solved by simultaneous algebraic reconstruction technique (SART)+TV and alternating direction method of multipliers (ADMM). Compared to some TV-based reconstruction methods, the experimental results show that our method can further improve the quality of reconstructed images and suppress the limited-angle artifacts as well as preserve the low contrast objects.
Computed tomography (CT) has its irreplaceable function in nondestructive testing and medical diagnosis. In some practical CT imaging applications, the limited-angle scanning is common due to X-ray's potential harm to human and the limitation of the scanning conditions. Under these circumstances, analytic reconstruction algorithms, like filtered backprojection (FBP), will not obtain satisfactory results because of lacking the projection data. Iterative reconstruction (IR) methods that can incorporate prior knowledge have attracted attention in many fields, and wavelet frame-based regularization reconstruction algorithms have proven to be a useful means to reduce slope artifacts and noise for limited-angle CT. However, with the obtained projection data of the scanned object further reduces, the edge structures and the details of the reconstructed image worsen. For the sake of improving the quality of the reconstructed image from the limited-angle projection data, a guided image filtering (GIF)-based limited-angle CT reconstruction algorithm using wavelet frame was proposed. In each iteration of the proposed algorithm, the reconstructed result constrained by the wavelet frame was used as the guidance image to transfer the important features it contains to the reconstructed result of SART method by GIF. Furthermore, some simulated experiments and real data tests were conducted to evaluate the feasibility and validity of the proposed algorithm, and the qualitative and quantitative indexes indicated that the proposed algorithm was superior to other iterative reconstruction algorithms in artifacts reduction, noise suppression, and structure preservation.
23 March 2018 in Journal of Inverse and Ill-posed Problems
The limited-angle computed tomography (CT) reconstruction problem is an ill-posed inverse problem, and the parameter selection for limited-angle CT iteration reconstruction is a difficult issue in practical application. In this paper, to alleviate the instability of limited-angle CT reconstruction problem and automatize the reconstruction process, we propose an adaptive iteration reconstruction method that the regularization parameter is chosen adaptively via the plot of the normalized wavelet coefficients fitting residual versus that the ℓ 0 {\ell_{0}} regularization part. The experimental results show that the reconstructed images using the method with adapted regularization parameter are almost as good as that using the non-adapted parameter method in terms of visual inspection, in addition, our method has an advantage in adaptively choosing the regularization parameter.
1 January 2018 in Review of Scientific Instruments
Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.
20 May 2022 in Medical & Biological Engineering & Computing
Limited-angle computed tomography (CT) reconstruction problem arises in some practical applications due to restrictions in the scanning environment or CT imaging device. Some artifacts will be presented in image reconstructed by conventional analytical algorithms. Although some regularization strategies have been proposed to suppress the artifacts, such as total variation (TV) minimization, there is still distortion in some edge portions of image. Guided image filtering (GIF) has the advantage of smoothing the image as well as preserving the edge. To further improve the image quality and protect the edge of image, we propose a coupling method, that combines gradient minimization and GIF. An intermediate result obtained by gradient minimization is regarded as a guidance image of GIF, then GIF is used to filter the result reconstructed by simultaneous algebraic reconstruction technique (SART) with nonnegative constraint. It should be stressed that the guidance image is dynamically updated as the iteration process, which can transfer the edge to the filtered image. Some simulation and real data experiments are used to evaluate the proposed method. Experimental results show that our method owns some advantages in suppressing the artifacts of limited angle CT and in preserving the edge of image.