Xiangji Yue

Dr. Xiangji Yue

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
DZDequan Zou
Dequan Zou
XYXiangji Yue
Xiangji Yue
THTianyi He
Tianyi He
JDJianan Ding
Jianan Ding
DBDechun Ba
Dechun Ba
Thermochemical adsorption energy storage is a potential energy utilization technology. Among these technologies, the composite energy storage material prepared by K2CO3 and expanded vermiculite (EVM) shows excellent performance. In this paper, the influence of the preparation process using the impregnation method and vacuum impregnation method on K2CO3/EVM composite material is studied. The preparation plan is further optimized with the solution concentration and the expanded vermiculite particle size as variables. In the experiment, mercury intrusion porosimetry (MIP) is used to measure the porosity and other parameters. Additionally, with the help of scanning electron microscopy (SEM), the morphological characteristics of the materials are obtained from a microscopic point of view. The effects of different preparation parameters are evaluated by comparing the experimental results. The results show that the K2CO3 specific gravity of the composite material increases with the increase of the vacuum degree, up to 70.440 wt.% (the vacuum degree is 6.7 kPa). Expanded vermiculite with a large particle size (3~6 mm) can carry more K2CO3, and content per cubic centimeter of K2CO3 can be as high as 0.466 g.

30 April 2021 in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
JDJianan Ding
Jianan Ding
XYXiangji Yue
Xiangji Yue
YZYingli Zhang
Yingli Zhang
DBDechun Ba
Dechun Ba
A mathematical modeling of working chamber volume, constructed from the involute of variable radii circle with double arcs modification, is established in this study. The formulations of working chamber volume which is consisted of the involute of variable radii circle and modified by double arcs at center profiles are accurately deduced, and the orbiting angle of scroll at every moment has a corresponding working chamber volume. The effect of parameters on the working chamber volume is investigated. The different values of initial radius of base circle, starting involute angle, corrected increment, polytropic index and modified angle will change the working chamber volume. Furthermore, the effect of parameters on suction volume and volume ratio has been considered in this study, and the design schemes to obtain the highest volume radio are also studied. These results can be used to provide general implications in calculation of working chamber volume constructed from other type involutes and modifications.

3 August 2022 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
JDJianan Ding
Jianan Ding
XYXiangji Yue
Xiangji Yue
YZYingli Zhang
Yingli Zhang
FYFan Yang
Fan Yang
HCHongjun Cao
Hongjun Cao
DBDechun Ba
Dechun Ba

18 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYing-Li Zhang
Ying-Li Zhang
XYXiangji Yue
Xiangji Yue
JDJianan Ding
Jianan Ding
DBDe-Chun Ba
De-Chun Ba
The dry scroll vacuum pump is a kind of variable capacity dry vacuum pump that is applied in chemical, pharmaceutical, semiconductor, and scientific instruments. Analyzing the thermodynamic characteristics of the scroll vacuum pump and studying the impact of operating temperature on its consistent performance are necessary for the design and application of the cooling system of the scroll vacuum pump. Based on the dynamics mesh method, the computational fluid dynamics (CFD) simulation model of a multi-stage dry scroll vacuum pump is established in this study. Under the suction pressure of 1000 Pa, the simulation calculation is carried out at different operating temperatures of fixed scrolls (25 °C, 45 °C, and 65 °C). The results show that the pumping speed, the gas compression power, and the energy efficiency ratio are significantly affected by different temperatures. The operating temperature of the pump has been reduced from 65 °C to 25 °C, the pumping speed is increased by approximately 5.97%, the gas compression power is increased by approximately 4.32%, and the energy efficiency ratio is increased by approximately 1.745%. This research provides a transient simulation method using dynamic mesh technology for the study of the dry scroll vacuum pump, and the results can provide a theoretical basis for the design and application of the cooling system of the dry scroll vacuum pump.

19 December 2024 in Vacuum
Verified
Journal Article
Closed access
YZYing-Li Zhang
Ying-Li Zhang
XYXiangji Yue
Xiangji Yue
DBDe-Chun Ba
De-Chun Ba
FYFan Yang
Fan Yang

14 May 2022 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
JDJianan Ding
Jianan Ding
XYXiangji Yue
Xiangji Yue
YZYingli Zhang
Yingli Zhang
DBDechun Ba
Dechun Ba
The working chamber volume and pressure constructed from involute of variable radii circle with line-arcs modification are calculated accurately by equivalent translation area method avoiding complicated piece-wise integration and Green’s theorem. The influence of modified distance is divided into two benchmarks to investigate because the interval length of the discharge process is always 2 π. The increase of modified distance will decrease the working chamber volume before the discharge process and increase the volume in the discharge process. Afterward, the volume change rate is proposed to study the tangent slope of volume curve, which is also meaningful for discussing the working chamber pressure. Finally, the working chamber pressure is obtained by the working chamber volume. The increase of modified angle and distance will increase the working chamber pressure in the same orbiting angle before the discharge process, but decrease the discharge pressure and advance the discharge process. Furthermore, the influences of modified parameters on the working chamber pressure in the discharge process are qualitatively studied. The increase of modified parameters will decrease the working chamber pressure in the discharge process.