We have described the use of 3-dimensional (3D) virtual planning and 3D printed patient-specific osteotomy templates in the surgical correction of a complex spinal deformity. Pedicle subtraction osteotomies (PSOs) for the correction of severe spinal deformities are technically demanding procedures with a risk of major complications. In particular, operations of the severely deformed spine call for new, more precise, methods of surgical planning. The new 3D technology could result in new possibilities for the surgical planning of spinal deformities. We present the case of severe congenital kyphoscoliosis in a young girl with skeletal dysplasia. A closing wedge-extended PSO was 3D virtual planned using medical computer design software. After the optimal 3D-wedge procedure was planned, individualized osteotomy-guiding templates were designed for translation of the planned PSO to the surgical procedure. During surgery, the PSO was performed using the osteotomy templates. Successful correction of the kyphoscoliosis was realized. The kyphosis was successfully reduced using a wedge-shaped extended PSO using preoperative 3D virtual planning, assisted by 3D-printed individualized osteotomy-guiding templates. In addition to direct translation of the planned PSO for surgery, the 3D planning also facilitated a detailed preoperative evaluation, greater insight into the case-specific anatomy, and accurate planning of the required correction.
Study Design.: Single-center retrospective case series. Objective.: The purpose of this study was to assess the safety and accuracy of three-dimensional (3D)-printed individualized drill guides for pedicle and lateral mass screw insertion in the cervical and upper-thoracic region, by comparing the preoperative 3D surgical plan with the postoperative results. Summary of Background Data.: Posterior spinal fusion surgery can provide rigid intervertebral fixation but screw misplacement involves a high risk of neurovascular injury. However, modern spine surgeons now have tools such as virtual surgical planning and 3D-printed drill guides to facilitate spinal screw insertion. Methods.: A total of 15 patients who underwent posterior spinal fusion surgery involving patient-specific 3D-printed drill guides were included in this study. After segmentation of bone and screws, the postoperative models were superimposed onto the preoperative surgical plan. The accuracy of the realized screw trajectories was quantified by measuring the entry point and angular deviation. Results.: The 3D deviation analysis showed that the entry point and angular deviation over all 76 screw trajectories were 1.40 ± 0.81 mm and 6.70 ± 3.77°, respectively. Angular deviation was significantly higher in the sagittal plane than in the axial plane (P = 0.02). All screw positions were classified as “safe” (100%), showing no neurovascular injury, facet joint violation, or violation of the pedicle wall. Conclusions.: 3D virtual planning and 3D-printed patient-specific drill guides appear to be safe and accurate for pedicle and lateral mass screw insertion in the cervical and upper-thoracic spine. The quantitative 3D deviation analyses confirmed that screw positions were accurate with respect to the 3D-surgical plan. Level of Evidence: 4
BACKGROUND: Accurate cervical screw insertion is of paramount importance considering the risk of damage to adjacent vital structures. Recent research in 3-dimensional (3D) technology describes the advantage of patient-specific drill guides for accurate screw positioning, but consensus about the optimal guide design and the accuracy is lacking. OBJECTIVE: To find the optimal design and to evaluate the accuracy of individualized 3D-printed drill guides for lateral mass and pedicle screw placement in the cervical and upper thoracic spine. METHODS: Five Thiel-embalmed human cadavers were used for individualized drill-guide planning of 86 screw trajectories in the cervical and upper thoracic spine. Using 3D bone models reconstructed from acquired computed tomography scans, the drill guides were produced for both pedicle and lateral mass screw trajectories. During the study, the initial minimalistic design was refined, resulting in the advanced guide design. Screw trajectories were drilled and the realized trajectories were compared to the planned trajectories using 3D deviation analysis. RESULTS: The overall entry point and 3D angular accuracy were 0.76 ± 0.52 mm and 3.22 ± 2.34°, respectively. Average measurements for the minimalistic guides were 1.20 mm for entry points, 5.61° for the 3D angulation, 2.38° for the 2D axial angulation, and 4.80° for the 2D sagittal angulation. For the advanced guides, the respective measurements were 0.66 mm, 2.72°, 1.26°, and 2.12°, respectively. CONCLUSION: The study ultimately resulted in an advanced guide design including caudally positioned hooks, crosslink support structure, and metal inlays. The novel advanced drill guide design yields excellent drilling accuracy.
Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique. Methods: All patients (≥12 years) treated for post-traumatic malunion with a two-step 3D-planned corrective osteotomy within our center in 2021 were prospectively included. Three-dimensional virtual models of the planned outcome and the clinically achieved outcome were obtained and aligned. Postoperative evaluation of the accuracy of performed corrections was assessed by measuring the preoperative and postoperative alignment error in terms of angulation, rotation and translation. Results: A total of 10 patients were included. All corrective osteotomies were performed according to the predetermined surgical plan without any complications. The preoperative deformities ranged from 7.1 to 27.5° in terms of angulation and 5.3 to 26.1° in terms of rotation. The achieved alignment deviated on average 2.1 ± 1.0 and 3.4 ± 1.6 degrees from the planning for the angulation and rotation, respectively. Conclusions: A two-step approach for 3D-guided patient-specific corrective limb osteotomies is reliable, feasible and accurate.
Study Design.: Screw randomized cadaveric study. Objective.: To compare the accuracy of three-dimensional (3D)-printed drill guides versus additional screw guiding techniques for challenging intra- and extrapedicular screw trajectories. Summary of Background Data.: Pedicle screw placement can be technically demanding, especially in syndromic scoliosis with limited bone stock. Recently, 3D-printing and virtual planning technology have become available as new tools to improve pedicle screw insertion. Differences in techniques exist, while some focus on guiding the drill, others also actively guide subsequent screws insertion. The accuracy of various 3D-printing-assisted techniques has been studied; however, direct comparative studies have yet to determine whether there is a benefit of additional screw guidance. Methods.: Two cadaveric experiments were conducted to compare drill guides with two techniques that introduce additional screw guiding. The screw guiding consisted of either k-wire cannulated screws or modular guides, which were designed to guide the screw in addition to the drill bit. Screws were inserted intra- or extrapedicular using one of each methods according to a randomization scheme. Postoperative computed tomography scanning was performed and fused with the preoperative planning for detailed 3D screw deviation analysis. Results.: For intrapedicular screw trajectories malpositioning was low (2%) and the modular guides revealed a statistically significant increase of accuracy (P= 0.05) compared with drill guides. All techniques showed accurate cervical screw insertion without breach. For the extrapedicular screw trajectories both additional screw guiding methods did not significantly (P = 0.09) improve accuracy and malpositioning rates remained high (24%). Conclusions.: In this cadaveric study it was found that the additional screw-guiding techniques are not superior to the regular 3D-printed drill guides for the technically demanding extrapedicular screw technique. For intrapedicular screw insertion, modular guides can improve insertion; however, at cervical levels regular 3D-printed drill guides already demonstrated very high accuracy and therefore there is no benefit from additional screw guiding techniques. Level of Evidence.: 3