Nick Assink

Mr. Nick Assink

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2021 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
NANick Assink
Nick Assink
IRInge H. F. Reininga
Inge H. F. Reininga
KDKaj Ten Duis
Kaj Ten Duis
JDJob N. Doornberg
Job N. Doornberg
HHHarm Hoekstra
Harm Hoekstra
FIFrank F. A. Ijpma
Frank F. A. Ijpma
Purpose: The aim of this systematic review was to provide an overview of current applications of 3D technologies in surgical management of tibial plateau fractures and to assess whether 3D-assisted surgery results in improved clinical outcome as compared to surgery based on conventional imaging modalities. Methods: A literature search was performed in Pubmed and Embase for articles reporting on the use of 3D techniques in operative management of tibial plateau fractures. This systematic review was performed in concordance with the PRISMA-guidelines. Methodological quality and risk of bias was assessed according to the guidelines of the McMaster Critical Appraisal. Differences in terms of operation time, blood loss, fluoroscopy frequency, intra-operative revision rates and patient-reported outcomes between 3D-assisted and conventional surgery were assessed. Data were pooled using the inverse variance weighting method in RevMan. Results: Twenty articles evaluating 948 patients treated with 3D-assisted surgery and 126 patients with conventional surgery were included. Five different concepts of 3D-assisted surgery were identified: ‘3D virtual visualization’, ‘3D printed hand-held fracture models’, ‘Pre-contouring of osteosynthesis plates’, ‘3D printed surgical guides’, and ‘Intra-operative 3D imaging’. 3D-assisted surgery resulted in reduced operation time (104.7 vs. 126.4 min; P < 0.01), less blood loss (241 ml vs. 306 ml; P < 0.01), decreased frequency of fluoroscopy (5.8 vs. 9.1 times; P < 0.01). No differences in functional outcome was found (Hospital for Special Surgery Knee-Rating Scale: 88.6 vs. 82.8; P = 0.23). Conclusions: Five concepts of 3D-assisted surgical management of tibial plateau fractures emerged over the last decade. These include 3D virtual fracture visualization, 3D-printed hand-held fracture models for surgical planning, 3D-printed models for pre-contouring of osteosynthesis plates, 3D-printed surgical guides, and intra-operative 3D imaging. 3D-assisted surgery may have a positive effect on operation time, blood loss, and fluoroscopy frequency.

17 May 2023 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
NANick Assink
Nick Assink
MMMostafa El Moumni
Mostafa El Moumni
Joep KraeimaJoep Kraeima
Joep Kraeima
EBEelke Bosma
Eelke Bosma
RNRobert J. Nijveldt
Robert J. Nijveldt
FIFrank IJpma
Frank IJpma
Background: Radiographic measurements of initial displacement of tibial plateau fractures and of postoperative reduction are used to determine treatment strategy and prognosis. We assessed the association between radiographic measurements and the risk of conversion to total knee arthroplasty (TKA) at the time of follow-up. Methods: A total of 862 patients surgically treated for tibial plateau fractures between 2003 and 2018 were eligible for this multicenter cross-sectional study. Patients were approached for follow-up, and 477 (55%) responded. The initial gap and step-off were measured on the preoperative computed tomography (CT) scans of the responders. Condylar widening, residual incongruity, and coronal and sagittal alignment were measured on postoperative radiographs. Critical cutoff values for gap and step-off were determined using receiver operating characteristic curves. Postoperative reduction measurements were categorized as adequate or inadequate on the basis of cutoff values in international guidelines. Multivariable analysis was performed to assess the association between each radiographic measurement and conversion to TKA. Results: Sixty-seven (14%) of the patients had conversion to TKA after a mean follow-up of 6.5 ± 4.1 years. Assessment of the preoperative CT scans revealed that a gap of >8.5 mm (hazard ratio [HR] = 2.6, p < 0.001) and step-off of >6.0 mm (HR = 3.0, p < 0.001) were independently associated with conversion to TKA. Assessment of the postoperative radiographs demonstrated that residual incongruity of 2 to 4 mm was not associated with increased risk of TKA compared with adequate fracture reduction of 4 mm resulted in increased risk of TKA. Coronal (HR = 1.6, p = 0.05) and sagittal malalignment (HR = 3.7 p < 0.001) of the tibia were strongly associated with conversion to TKA. Conclusions: Substantial preoperative fracture displacement was a strong predictor of conversion to TKA. Postoperative gaps or step-offs of >4 mm as well as inadequate alignment of the tibia were strongly associated with an increased risk of TKA. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

1 June 2022 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
TVThijs P. Bsc Vaartjes
Thijs P. Bsc Vaartjes
NANick Assink
Nick Assink
RNRobert J. Nijveldt
Robert J. Nijveldt
SHSvenhjalmar H. van Helden
Svenhjalmar H. van Helden
EBEelke Bosma
Eelke Bosma
FIFrank IJpma
Frank IJpma
Background: Gap and stepoff measurements provide information about fracture displacement and are used for clinical decision-making when choosing either operative or nonoperative management of tibial plateau fractures. However, there is no consensus about the maximum size of gaps and stepoffs on CT images and their relation to functional outcome in skeletally mature patients with tibial plateau fractures who were treated without surgery. Because this is important for patient counseling regarding treatment and prognosis, it is critical to identify the limits of gaps and stepoffs that are well tolerated. Questions/purposes: (1) In patients treated nonoperatively for tibial plateau fractures, what is the association between initial fracture displacement, as measured by gaps and stepoffs at the articular surface on a CT image, and functional outcome? (2) What is the survivorship of the native joint, free from conversion to a total knee prosthesis, among patients with tibial plateau fractures who were treated without surgery? Methods: A multicenter cross-sectional study was performed in all patients who were treated nonoperatively for a tibial plateau fracture between 2003 and 2018 in four trauma centers. All patients had a diagnostic CT scan, and a gap and/or stepoff more than 2 mm was an indication for recommending surgery. Some patients with gaps and/or stepoffs exceeding 2 mm might not have had surgery based on shared decision-making. Between 2003 and 2018, 530 patients were treated nonoperatively for tibial plateau fractures, of which 45 had died at follow-up, 30 were younger than 18 years at the time of injury, and 10 had isolated tibial eminence avulsions, leaving 445 patients for follow-up analysis. All patients were asked to complete the validated Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire consisting of five subscales: symptoms, pain, activities of daily living (ADL), function in sports and recreation, and knee-related quality of life (QOL). The score for each subscale ranged from 0 to 100, with higher scores indicating better function. A total of 46% (203 of 445) of patients participated at a mean follow-up of 6 ± 3 years since injury. All knee radiographs and CT images were reassessed, fractures were classified, and gap and stepoff measurements were taken. Nonresponders did not differ much from responders in terms of age (53 ± 16 years versus 54 ± 20 years; p = 0.89), gender (70% [142 of 203] women versus 59% [142 of 242] women; p = 0.01), fracture classifications (Schatzker types and three-column concept), gaps (2.1 ± 1.3 mm versus 1.7 ± 1.6 mm; p = 0.02), and stepoffs (2.1 ± 2.2 mm versus 1.9 ± 1.7 mm; p = 0.13). In our study population, the mean gap was 2.1 ± 1.3 mm and stepoff was 2.1 ± 2.2 mm. The participating patients divided into groups with increasing fracture displacement based on gap and/or stepoff (< 2 mm, 2 to 4 mm, or > 4 mm), as measured on CT images. ANOVA was used to assess whether an increase in the initial fracture displacement was associated with poorer functional outcome. We estimated the survivorship of the knee free from conversion to total knee prosthesis at a mean follow-up of 5 years using a Kaplan-Meier survivorship estimator. Results: KOOS scores in patients with a less than 2 mm, 2 to 4 mm, or greater than 4 mm gap did not differ (symptoms: 83 versus 83 versus 82; p = 0.98, pain: 85 versus 83 versus 86; p = 0.69, ADL: 87 versus 84 versus 89; p = 0.44, sport: 65 versus 64 versus 66; p = 0.95, QOL: 70 versus 71 versus 74; p = 0.85). The KOOS scores in patients with a less than 2 mm, 2 to 4 mm, or greater than 4 mm stepoff did not differ (symptoms: 84 versus 83 versus 77; p = 0.32, pain: 85 versus 85 versus 81; p = 0.66, ADL: 86 versus 87 versus 82; p = 0.54, sport: 65 versus 68 versus 56; p = 0.43, QOL: 71 versus 73 versus 61; p = 0.19). Survivorship of the knee free from conversion to total knee prosthesis at mean follow-up of 5 years was 97% (95% CI 94% to 99%). Conclusion: Patients with minimally displaced tibial plateau fractures who opt for nonoperative fracture treatment should be told that fracture gaps or stepoffs up to 4 mm, as measured on CT images, could result in good functional outcome. Therefore, the arbitrary 2-mm limit of gaps and stepoffs for tibial plateau fractures could be revisited. The survivorship of the native knee free from conversion to a total knee prosthesis was high. Large prospective cohort studies with high response rates are needed to learn more about the relationship between the degree of fracture displacement and functional recovery after tibial plateau fractures. Level of Evidence: Level III, prognostic study.

20 October 2022 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
NANick Assink
Nick Assink
Joep KraeimaJoep Kraeima
Joep Kraeima
AMAnne Meesters
Anne Meesters
MMMostafa El Moumni
Mostafa El Moumni
EBEelke Bosma
Eelke Bosma
FIFrank IJpma
Frank IJpma
Purpose: Currently used classification systems and measurement methods are insufficient to assess fracture displacement. In this study, a novel 3D measure for fracture displacement is introduced and associated with risk on conversion to total knee arthroplasty (TKA). Methods: A multicenter cross-sectional study was performed including 997 patients treated for a tibial plateau fracture between 2003 and 2018. All patients were contacted for follow-up and 534 (54%) responded. For all patients, the 3D gap area was determined in order to quantify the degree of initial fracture displacement. A cut-off value was determined using ROC curves. Multivariate analysis was performed to assess the association of 3D gap area with conversion to TKA. Subgroups with increasing levels of 3D gap area were identified, and Kaplan–Meier survival curves were plotted to assess survivorship of the knee free from conversion to TKA. Results: A total of 58 (11%) patients underwent conversation to TKA. An initial 3D gap area ≥ 550 mm2 was independently associated with conversion to TKA (HR 8.4; p = 0.001). Four prognostic groups with different ranges of the 3D gap area were identified: excellent (0–150 mm2), good (151–550 mm2), moderate (551–1000 mm2), and poor (> 1000 mm2). Native knee survival at 10-years follow-up was 96%, 95%, 76%, and 59%, respectively, in the excellent, good, moderate, and poor group. Conclusion: A novel 3D measurement method was developed to quantify initial fracture displacement of tibial plateau fractures. 3D fracture assessment adds to current classification methods, identifies patients at risk for conversion to TKA at follow-up, and could be used for patient counselling about prognosis. Level of evidence: Prognostic Level III.

30 June 2023 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
NANick Assink
Nick Assink
MOMiriam G. E. Oldhoff
Miriam G. E. Oldhoff
KDKaj ten Duis
Kaj ten Duis
Joep KraeimaJoep Kraeima
Joep Kraeima
JDJob N. Doornberg
Job N. Doornberg
FIFrank IJpma
Frank IJpma
Purpose: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures. Methods: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction. Results: A total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5–9.5) to 0.9 mm (IQR 0.2–1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1–5.3) to 1.3 mm (IQR 0.9–1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8–3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5–5.1). Conclusion: This feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.

6 September 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
NANick Assink
Nick Assink
AMAnne Meesters
Anne Meesters
KDKaj ten Duis
Kaj ten Duis
JHJorrit S. Harbers
Jorrit S. Harbers
FIFrank IJpma
Frank IJpma
Joep KraeimaJoep Kraeima
Joep Kraeima
Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique. Methods: All patients (≥12 years) treated for post-traumatic malunion with a two-step 3D-planned corrective osteotomy within our center in 2021 were prospectively included. Three-dimensional virtual models of the planned outcome and the clinically achieved outcome were obtained and aligned. Postoperative evaluation of the accuracy of performed corrections was assessed by measuring the preoperative and postoperative alignment error in terms of angulation, rotation and translation. Results: A total of 10 patients were included. All corrective osteotomies were performed according to the predetermined surgical plan without any complications. The preoperative deformities ranged from 7.1 to 27.5° in terms of angulation and 5.3 to 26.1° in terms of rotation. The achieved alignment deviated on average 2.1 ± 1.0 and 3.4 ± 1.6 degrees from the planning for the angulation and rotation, respectively. Conclusions: A two-step approach for 3D-guided patient-specific corrective limb osteotomies is reliable, feasible and accurate.