Yong Zhu

Mr. Yong Zhu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
CJChenglong Jia
Chenglong Jia
WZWenbin Zhao
Wenbin Zhao
YZYong Zhu
Yong Zhu
WLWu Lu
Wu Lu
ZTZhong Tang
Zhong Tang
The optimized concentration of SF6 gas is the key to maintaining a good insulation performance by GIS equipment. The precise measurements of the SF6 concentration and decomposition byproducts could be used to indicate the remaining GIS insulation level during long-term operations. In this paper, a finite-element simulation model was created to investigate the SF6 gas decomposition and diffusion dynamics. A theoretical analysis and simulation of the overheating fault, i.e., the contact between the GIS disconnect switches, were carried out, followed by an estimation of the SF6 decomposition and diffusion characteristics caused by the local heating faults, based on the calculated flow velocity field and temperature field.

8 September 2022 in Frontiers in Energy Research
Verified
Journal Article
Open access
GYGuang Yang
Guang Yang
YZYong Zhu
Yong Zhu
FZFanxing Zen
Fanxing Zen
SZShengzhi Zhou
Shengzhi Zhou
YCYuhang Chen
Yuhang Chen
New energy systems, such as wind power and photovoltaic and distributed power supply, in the power generation and grid-connected transmission system basically will use stronger insulation design, higher operational safety, and smaller footprint GIL equipment, while the new energy transmission system of the smart grid development trend requires accompanying the electronic transformer equipment to promote a large area. However, the current GIL equipment used in new energy transmission systems has caused great electromagnetic interference to the electronic equipment due to the compact layout of the equipment and the transient signals generated by normal operation, which has seriously restricted the development of smart grids and became a major obstacle to the grid connection of new energy systems. In order to study the characteristics and developmental law of transient electromagnetic interference signal of GIL equipment in new energy transmission and transformation system, this study proposes a dynamic arc model based on an optimized arc extinguishing criterion, verifies the correctness of the improved dynamic arc model through theoretical analysis, simulates calculation combined with the test measurement data, and compares and analyzes the simulation results with test measurement data to study the transient electromagnetic interference source signal during arc burning duration. The simulation results and test data are compared and analyzed to study the pulse steepness, size of the wave head, and overall waveform development law of the transient electromagnetic interference source signal during the arc burning process. It is concluded that the dynamic arc model based on the optimized arc extinguishing criterion can be better used to study the transient electromagnetic interference signal in the GIL equipment. Meanwhile, the transient electromagnetic interference signal has the characteristics of large amplitude and high frequency, the maximum overvoltage can reach 1.9 p.u., the UHF can reach 30 MHz, and the wave head rise time is about 12 ns. This study provides theoretical support for subsequent research on suppressing transient electromagnetic interference source signals, improving the anti-electromagnetic interference performance of electronic devices, and is dedicated to solving the obstruction problem in the process of grid connection of new energy transmission and substation systems.

13 December 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
CLCheng Lin
Cheng Lin
YZYong Zhu
Yong Zhu
FCFan Chen
Fan Chen
HYHuaxing Yu
Huaxing Yu
CZCheng Zhang
Cheng Zhang
YLYifeng Liang
Yifeng Liang
With the continuous improvement of substation voltage level and the wide use of GAS insulated SWITCHGEAR (GIS), switching overvoltage, especially the very fast transient overvoltage (VFTO) caused by disconnector operation, has attracted more and more attention. According to the demonstration project of a new generation intelligent substation with the highest voltage grade (330kV) in operation in China, analysing the physical process of VFTO generation and propagation in high voltage substation by combining simulation calculation with test detection. Taking the electronic current transformer of intelligent secondary equipment as an example, its exploitation is established. We got the output signal waveform of the acquisition unit port under the action of VFTO by the high frequency transient model of the unit. By comparing the distribution parameters and the measured signal waveforms, the high frequency characteristics of the acquisition unit of the electronic current transformer under the action of VFTO are reflected. The results show that the EMI of the acquisition unit of electronic current transformer is in the form of pulse group. The amplitude of EMI is about 900V and the stable impact frequency is about 50 kHz. The impact frequency directly related to the arc reburning frequency.