This paper proposes a joint visualization detection method to diagnose outdoor insulation status of high-voltage (HV) equipment in substations, which applies image matching and fusion techniques to accurately combine the results of ultrasonic, ultraviolet, and infrared detection in an image. This image can then be used to quickly and clearly locate the region of corona discharge and overheating of outdoor substation HV equipment. First, ultrasonic localization visualization of corona discharge is proposed, which is based on the designed double-helix array and multi-signal classification algorithm. This method provides a more intuitive way for the diagnosis of outdoor insulation status. Then, ultraviolet localization visualization method is detailed, and an adaptive affine matrix is designed for the accurate location of corona discharge. Following this, infrared-visible detection of overheating failure is introduced, and the speeded-up robust features (SURF) algorithm and random sample consensus (RANSAC) algorithm are used to implement image fusion process. Finally, the results of image fusion are provided, and location error evaluations are conducted for each module. With acceptable cost and advantages of three detection method, the proposed visualization method is used for evaluating the insulation status of substation equipment more intuitively and conveniently, and thus has an extensive application prospect.
The optimized concentration of SF6 gas is the key to maintaining a good insulation performance by GIS equipment. The precise measurements of the SF6 concentration and decomposition byproducts could be used to indicate the remaining GIS insulation level during long-term operations. In this paper, a finite-element simulation model was created to investigate the SF6 gas decomposition and diffusion dynamics. A theoretical analysis and simulation of the overheating fault, i.e., the contact between the GIS disconnect switches, were carried out, followed by an estimation of the SF6 decomposition and diffusion characteristics caused by the local heating faults, based on the calculated flow velocity field and temperature field.
1 September 2024 in Journal of Renewable and Sustainable Energy
The hot spot effect is one of the primary causes of damage to photovoltaic (PV) modules and a significant factor contributing to the decline in their power generation capacity. Thermal imaging inspection of PV modules is an indispensable aspect of PV plant operation and maintenance. This article introduces a lightweight detection algorithm for hot spots in PV modules based on an enhanced version of YOLOv8. The algorithm incorporates a lightweight convolution operator, Volumetric Grid Spatial Cross Stage Partial, as a replacement for the original C2f operator, resulting in effective reduction of the model's parameter size and improved detection speed. Additionally, the Content-Aware ReAssembly of FEatures upsampling operator is utilized instead of the nearest-neighbor algorithm during the upsampling process, thereby minimizing the loss of hot spot feature information. Furthermore, a joint metric approach combining the Complete Intersection over Union metric and the normalized Wasserstein distance metric is proposed to calculate the localization loss of the target bounding boxes, thereby enhancing the regression accuracy of small hot spot prediction boxes. Experimental results demonstrate that the improved YOLOv8 network enables fast and accurate detection of hot spots. This method achieves an impressive average precision of 98.8% and a high detection speed of 218.3 fps.
Conventional high-voltage direct current (HVDC) systems based on line-commutated converters (LCC) are prone to commutation failures and consume excessive reactive power during AC grid faults. The controllable line-commutated converter (CLCC) was developed to solve these problems. To further investigate CLCC’s practical application in the AC system, this paper proposes a fixed AC voltage control strategy for the inverter-side CLCC. A hybrid LCC-CLCC HVDC transmission system model is built in PSCAD. Simulations are performed under three-phase short-circuit faults and wind power fluctuation scenarios. The results show that, unlike traditional LCC, the CLCC under the proposed control can actively increase its firing angle over 160 degrees during disturbances. This action injects dynamic reactive power into the grid and significantly reduces the AC bus voltage drop. Especially in weak grid conditions, CLCC can greatly reduce reactive power consumption through wide-range active adjustment of the firing angle, thereby improving voltage stability.
A Controllable Line-Commutated Converter (CLCC) is a novel piece of equipment for enhancing the commutation failure resistance of High-Voltage Direct Current (HVDC) transmission systems. Traditional lumped parameter models ignore the high-frequency coupling effects of internal distributed stray capacitances, resulting in insufficient transient simulation accuracy and restricting refined engineering design. Taking the CLCC in the HVDC transformation project as the research object, this paper analyzes the distribution characteristics of stray parameters in a press-pack Insulated Gate Bipolar Transistor (IGBT) under stacked structures. By integrating distributed stray parameter networks with the nonlinear characteristics of the devices, an improved IGBT equivalent circuit model is established, with key parameters identified based on field-measured data. Furthermore, an LCC-CLCC simulation model is built and used to replace the improved IGBT model to conduct short-circuit fault simulation verification. The results demonstrate that the high-fidelity model accurately reproduces transient waveforms under Alternating Current (AC) voltage disturbance and faithfully reflects the actual operating characteristics of a surge arrester and IGBT, thereby effectively compensating for the idealized errors inherent in traditional models. This modeling methodology provides a robust theoretical and simulation foundation for parameter optimization, valve control system design, and the secure operation of a CLCC.
Large oil-immersed power transformers are core equipment in power grids, and the use of robots for internal inspection can significantly enhance efficiency. However, existing research has primarily focused on the development of robotic bodies, neglecting the potential impact of their operation on the transformer’s oil–paper insulation system. This paper addresses this issue, evaluates the risk of underwater inspection robots colliding with internal structures, and finds that the maximum elongation rate of insulation paperboard at a speed of 0.1 m/s is far below the damage limit. Simultaneously, it analyzes the process by which propellers induce bubbles in oil, pointing out the need to optimize propeller design to ensure insulation safety. The study also extends the classical cavitation theory in water to the oil medium, reveals the conditions for gas generation by the propeller and the variation in the patterns of gas components (such as C2H2, H2, etc.) through experiments, and discusses the gas source issue of cavitation in oil.