The electric impedance of piezoelectric ceramics is influenced by variations in the acoustic load. This situation is very common for ultrasonic applications in medicine where the irradiated media can present different interfaces and impedances to the propagating acoustic energy. In this work we analyzed the behavior of the resonances, anti-resonances and the effective electromechanical coupling factor of a piezoelectric ceramic ring vibrating in thickness mode. The analysis is based on equivalent electric circuits and considers variations in the acoustic load. The results showed that the electric impedance of the ceramic is altered with the length of the acoustic load, resulting in new resonances and changing the effective electromechanical coupling factor. Electronic circuits for driving piezoelectric transducers must be able to correct the frequencies if acoustic loads vary.
1 March 2015 in Journal of Water Resources Planning and Management
Although pre-stressing is a requirement for the operation of a high-power piezo transducers, its impact on the model, the performance and the design of such devices is still not yet fully covered in the literature. This work attempts to bridge this gap by analyzing how the components of the Butterworth-Van Dyke model, the resonances, electrical impedances, electromechanical coupling factor, mechanical losses, and the tuning inductance are determined as a function of mechanical pre-stress. We have employed the Butterworth Van-Dyke model to study piezoelectric transducers tightened with a range of pre-stressing levels (12.2–60.1 MPa). As expected, the experimental results indicate that the components of the Butterworth-Van Dyke model are dependent upon the mechanical pre-stressing. The conclusions point out that, under mechanical pre-stressing levels between a threshold value and 60.1 MPa, the transducers used in this work tend to stabilize and enhance their performances. Also, upon stabilization, the transducers can be tuned with a constant inductance, which may also aid the design of ultrasonic systems. Overall, this work contributes to the definition of pre-stressing levels and its relationship with the length of the transducer, the mechanical losses, and the tuning.
In this work, we have studied the electrical response of a sandwiched piezoelectric transducer as a function of the height of a water column used as an acoustical load. This study covers investigations about the behavior of resonance, anti-resonance, electromechanical coupling factor, motional resistance, and mechanical loss. The results show that the performance of the transducer is dependent on the acoustic load. The heights where the conversion is maximum coincides with the minimum value for the mechanical loss. These results can be used for the design of the hardware in ultrasonic systems that include dynamical resonance tracking and control of power supply.
18 June 2012 in Microwave and Optical Technology Letters