Voltammetric techniques have been considered as an important analytical tool applied to the determination of trace concentrations of many biological molecules including ascorbic acid. In this paper, ascorbic acid was detected by square wave voltammetry, using graphene oxide paste as a working electrode, modified by a film of a manganese(II) complex compound. Various factors, such as the effect of pH, affecting the response characteristics of the modified electrode were investigated. The relationship between the peak height and ascorbic acid concentration within the modified working electrode was investigated, using the calibration graph. The equation of the calibration graph was found to be: I = 0.0550γac + 0.155 with R2 = 0.9998, where I is the SWV current and γac is the mass concentration of ascorbic acid. The LOD and LOQ of the proposed method were determined to be 1.288 μg/L and 3.903 μg/L, respectively. Several compounds, such as riboflavin, biotin, and ions, such as Fe and Cu, were tested and it seemed that they did not interfere with the analytic signal. The proposed procedure was successfully applied in the determination of ascorbic acid in Rosa canina hips.
Determination of antibiotics is crucial in order to assess their potential impacts on human health and the environment. This study aimed to develop a modified glassy carbon electrode with saffron conjugated silver nanoparticles for the determination of amoxicillin antibiotic in urine samples. The modified electrode was prepared by electrodeposition of silver nanoparticles on the electrode surface, followed by deposition of amoxicillin on the surface. The electrochemical behavior of the modified electrode was studied by cyclic voltammetry and square wave voltammetry. The results showed that the modified electrode exhibited enhanced electrocatalytic activity toward the oxidation of amoxicillin. The calibration curve was linear in the concentration range from 1.273 × 10−4 g L−1 to 2.217 × 10−3 g L−1, with a high linear correlation coefficient of 0.9998. The detection limit was determined to be 4.199 × 10−5 g L−1. The precision of the sensor was adequate, with relative standard deviations of 4.3% and 4.0% for AMX concentrations of 9.199 × 10−5 g L−1 and 1.194 × 10−4 g L−1, respectively. The modified electrode was then applied to the determination of amoxicillin in urine samples. The method showed linearity over the amoxicillin concentration range from 0.00 to 2.00 × 10−4 g L−1, with a detection limit of 9.739 × 10−6 g L−1, indicating the potential of the modified electrode for the determination of amoxicillin in biological samples. Overall, the modified glassy carbon electrode with silver nanoparticles showed very promising results for the sensitive and selective determination of amoxicillin in urine samples.