This review highlights the importance of monitoring the levels of antibiotics in different matrices and the need for sensitive and selective detection methods of antibiotic residues in various samples. Additionally, this article discusses the use of modified electrodes, specifically those modified with nanoparticles, for the detection of antibiotics using electroanalytical techniques. These modified electrodes have been found to have advantages over unmodified electrodes, such as enhanced sensitivity, selectivity, and stability. Nanoparticles such as graphene, carbon nanotubes, metal nanoparticles, and metal oxides have been used to modify electrodes because of their excellent properties, such as their large electroactive surfaces. The review provides examples of nanoparticle-modified electrodes that have been used successfully for the determination of a broad range of antibiotics.
Determination of antibiotics is crucial in order to assess their potential impacts on human health and the environment. This study aimed to develop a modified glassy carbon electrode with saffron conjugated silver nanoparticles for the determination of amoxicillin antibiotic in urine samples. The modified electrode was prepared by electrodeposition of silver nanoparticles on the electrode surface, followed by deposition of amoxicillin on the surface. The electrochemical behavior of the modified electrode was studied by cyclic voltammetry and square wave voltammetry. The results showed that the modified electrode exhibited enhanced electrocatalytic activity toward the oxidation of amoxicillin. The calibration curve was linear in the concentration range from 1.273 × 10−4 g L−1 to 2.217 × 10−3 g L−1, with a high linear correlation coefficient of 0.9998. The detection limit was determined to be 4.199 × 10−5 g L−1. The precision of the sensor was adequate, with relative standard deviations of 4.3% and 4.0% for AMX concentrations of 9.199 × 10−5 g L−1 and 1.194 × 10−4 g L−1, respectively. The modified electrode was then applied to the determination of amoxicillin in urine samples. The method showed linearity over the amoxicillin concentration range from 0.00 to 2.00 × 10−4 g L−1, with a detection limit of 9.739 × 10−6 g L−1, indicating the potential of the modified electrode for the determination of amoxicillin in biological samples. Overall, the modified glassy carbon electrode with silver nanoparticles showed very promising results for the sensitive and selective determination of amoxicillin in urine samples.