Although the impact of therapeutic thoracentesis on lung function and blood gases has been evaluated in several studies, some physiological aspects of pleural fluid withdrawal remain unknown. The aim of the study was to assess the changes in pleural pressure amplitude (Pplampl) during the respiratory cycle and respiratory rate (RR) in patients undergoing pleural fluid withdrawal. The study included 23 patients with symptomatic pleural effusion. Baseline pleural pressure curves were registered with a digital electronic manometer. Then, the registrations were repeated after the withdrawal of consecutive portions of pleural fluid (200 ml up to 1000 ml and 100 ml above 1000 ml). In all patients the pleural pressure curves were analyzed in five points, at 0, 25%, 50%, 75% and 100% of the relative volume of pleural effusion withdrawn in particular patients. There were 11 and 12 patients with right sided and left sided pleural effusion, respectively (14 M, 9F, median age 68, range 46–85 years). The most common cause of pleural effusion were malignancies (20 pts., 87%). The median total volume of withdrawn pleural fluid was 1800 (IQR 1500–2400) ml. After termination of pleural fluid withdrawal Pplampl increased in 22/23 patients compared to baseline. The median Pplampl increased from 3.4 (2.4–5.9) cmH2O to 10.7 (8.1–15.6) cmH2O (p < 0.0001). Three patterns of Pplampl changes were identified. Although the patterns of RR changes were more diversified, a significant increase between RR at baseline and the last measurement point was found (p = 0.0097). In conclusion, therapeutic thoracentesis is associated with significant changes in Pplampl during the respiratory cycle. In the vast majority of patients Pplampl increased steadily during pleural fluid withdrawal. There was also an increase in RR. The significance of these changes should be elucidated in further studies. ClinicalTrial.gov, registration number: NCT02192138 , registration date: July 1st, 2014.
Recently, ‘medicine in silico’ has been strongly encouraged due to ethical and legal limitations related to animal experiments and investigations conducted on patients. Computer models, particularly the very complex ones (virtual patients—VP), can be used in medical education and biomedical research as well as in clinical applications. Simpler patient-specific models may aid medical procedures. However, computer models are unfit for medical devices testing. Hybrid (i.e., numerical–physical) models do not have this disadvantage. In this review, the chosen approach to the cardiovascular system and/or respiratory system modeling was discussed with particular emphasis given to the hybrid cardiopulmonary simulator (the artificial patient), that was elaborated by the authors. The VP is useful in the education of forced spirometry, investigations of cardiopulmonary interactions (including gas exchange) and its influence on pulmonary resistance during artificial ventilation, and explanation of phenomena observed during thoracentesis. The artificial patient is useful, inter alia, in staff training and education, investigations of cardiorespiratory support and the testing of several medical devices, such as ventricular assist devices and a membrane-based artificial heart.
1 June 2016 in The International Journal of Artificial Organs
The analysis of the efficiency and optimum use of cardiovascular and respiratory support systems is of great importance in research and development as well as in clinical practice. To understand the complex interaction between human cardiovascular or respiratory systems and the mechanical assist devices, a number of physical, computational or hybrid (physical-electrical or physical-computational) models/simulators have been developed and used in recent years. The hybrid models combine the advantages of both the physical models (interaction with assist devices) and of the computational/electrical models (accuracy, flexibility). This paper reviews the existing solutions and briefly describes their characteristics, advantages and disadvantages, chiefly emphasizing the features of the hybrid models that are most promising for future development.
Independent lung ventilation (ILV) is a life-saving procedure in unilateral pulmonary pathologies. ILV is underused in clinical practice, mostly due to the technically demanding placement of a double lumen endotracheal tube (ETT). Moreover, the determination of ventilation parameters for each lung in vivo is limited. In recent years, the development of 3D printing techniques enabled the production of highly accurate physical models of anatomical structures used for in vitro research, considering the high risk of in vivo studies. The purpose of this study was to assess the influence of double-lumen ETT on the gas transport and mixing in the anatomically accurate 3D-printed model of the bronchial tree, with lung lobes of different compliances, using various ventilation modes. The bronchial tree was obtained from Respiratory Drug Delivery (RDD Online, Richmond, VA, USA), processed and printed by a dual extruder FFF 3D printer. The test system was also composed of left side double-lumen endotracheal tube, Siemens Test Lung 190 and anesthetic breathing bag (as lobes). Pressure and flow measurements were taken at the outlets of the secondary bronchus. The measured resistance increased six times in the presence of double-lumen ETT. Differences between the flow distribution to the less and more compliant lobe were more significant for the airways with double-lumen ETT. The ability to predict the actual flow distribution in model airways is necessary to conduct effective ILV in clinical conditions.