Although the impact of therapeutic thoracentesis on lung function and blood gases has been evaluated in several studies, some physiological aspects of pleural fluid withdrawal remain unknown. The aim of the study was to assess the changes in pleural pressure amplitude (Pplampl) during the respiratory cycle and respiratory rate (RR) in patients undergoing pleural fluid withdrawal. The study included 23 patients with symptomatic pleural effusion. Baseline pleural pressure curves were registered with a digital electronic manometer. Then, the registrations were repeated after the withdrawal of consecutive portions of pleural fluid (200 ml up to 1000 ml and 100 ml above 1000 ml). In all patients the pleural pressure curves were analyzed in five points, at 0, 25%, 50%, 75% and 100% of the relative volume of pleural effusion withdrawn in particular patients. There were 11 and 12 patients with right sided and left sided pleural effusion, respectively (14 M, 9F, median age 68, range 46–85 years). The most common cause of pleural effusion were malignancies (20 pts., 87%). The median total volume of withdrawn pleural fluid was 1800 (IQR 1500–2400) ml. After termination of pleural fluid withdrawal Pplampl increased in 22/23 patients compared to baseline. The median Pplampl increased from 3.4 (2.4–5.9) cmH2O to 10.7 (8.1–15.6) cmH2O (p < 0.0001). Three patterns of Pplampl changes were identified. Although the patterns of RR changes were more diversified, a significant increase between RR at baseline and the last measurement point was found (p = 0.0097). In conclusion, therapeutic thoracentesis is associated with significant changes in Pplampl during the respiratory cycle. In the vast majority of patients Pplampl increased steadily during pleural fluid withdrawal. There was also an increase in RR. The significance of these changes should be elucidated in further studies. ClinicalTrial.gov, registration number: NCT02192138 , registration date: July 1st, 2014.
8 July 2017 in The International Journal of Artificial Organs
Purpose: Influence of therapeutic thoracentesis on the pleural pressure (Pp) has been discussed in many clinical studies, however reasons of Pp changes are not precisely established. The aim of the study was to use a previously elaborated virtual cardiopulmonary patient (VP) in analysis of impact of physiological factors on Pp during the procedure. Methods: Simulations were performed on VP with default values of parameters for which VP simulated the respiratory system of the average 50-year-old healthy Polish woman according to spirometric examination. Alterations of Pp and the amplitude of Pp changes related to breathing (AP) were analyzed. Model parameters related to chosen factors were deviated from their default values to analyze the degree of their impact on Pp and AP. The analysis was based on and supported by our own clinical data. Results: The Pp and AP alteration intensity appeared to be most sensitive to the compliances of the rib cage and mediastinum, and the nonlinearity of the dependence between the recoil pressure and the lung volume: the lower the compliances and the higher the nonlinearity were, the deeper the Pp fall during the procedure and the bigger the AP increase were observed. Conclusions: Experiments in silico are very useful in analyzing sophisticated physiological and medical problems. They made it possible to show which factors are particularly responsible for changes in Pp during thoracentesis. In the future, they may be useful in establishing objective conditions under which thoracentesis needs to be stopped.
Ventricular suction is a frequent adverse event in patients with a ventricular assist device (VAD). This study presents a suction module (SM) embedded in a hybrid (hydraulic-computational) cardiovascular simulator suitable for the testing of VADs and related suction events. The SM consists of a compliant latex tube reproducing a simplified ventricular apex. The SM is connected on one side to a hydraulic chamber of the simulator reproducing the left ventricle, and on the other side to a HeartWare HVAD system. The SM is immersed in a hydraulic chamber with a controllable pressure to occlude the compliant tube and activate suction. Two patient profiles were simulated (dilated cardiomyopathy and heart failure with preserved ejection fraction), and the circulating blood volume was reduced stepwise to obtain different preload levels. For each simulated step, the following data were collected: HVAD flow, ventricular pressure and volume, and pressure at the inflow cannula. Data collected for the two profiles and for decreasing preload levels evidenced suction profiles differing in terms of frequency (intermittent vs. every heart beat), amplitude (partial or complete stoppage of the HVAD flow), and shape. Indeed different HVAD flow patterns were observed for the two patient profiles because of the different mechanical properties of the simulated ventricles. Overall, the HVAD flow patterns showed typical indicators of suctions observed in clinics. Results confirmed that the SM can reproduce suction phenomena with VAD under different pathophysiological conditions. As such, the SM can be used in the future to test VADs and control algorithms aimed at preventing suction phenomena.
Independent lung ventilation (ILV) is a life-saving procedure in unilateral pulmonary pathologies. ILV is underused in clinical practice, mostly due to the technically demanding placement of a double lumen endotracheal tube (ETT). Moreover, the determination of ventilation parameters for each lung in vivo is limited. In recent years, the development of 3D printing techniques enabled the production of highly accurate physical models of anatomical structures used for in vitro research, considering the high risk of in vivo studies. The purpose of this study was to assess the influence of double-lumen ETT on the gas transport and mixing in the anatomically accurate 3D-printed model of the bronchial tree, with lung lobes of different compliances, using various ventilation modes. The bronchial tree was obtained from Respiratory Drug Delivery (RDD Online, Richmond, VA, USA), processed and printed by a dual extruder FFF 3D printer. The test system was also composed of left side double-lumen endotracheal tube, Siemens Test Lung 190 and anesthetic breathing bag (as lobes). Pressure and flow measurements were taken at the outlets of the secondary bronchus. The measured resistance increased six times in the presence of double-lumen ETT. Differences between the flow distribution to the less and more compliant lobe were more significant for the airways with double-lumen ETT. The ability to predict the actual flow distribution in model airways is necessary to conduct effective ILV in clinical conditions.
Objective: Computer simulations, enabling observations of variables inaccessible in living patients, provide a powerful approach to studying complex physiological phenomena. This in silico study presents the use of a virtual patient to investigate the impact of large pleural effusion (PE) and therapeutic thoracentesis (TT) on hemidiaphragm function and arterial blood gases.Methods: Inspired by unexpected phenomena observed in living patients undergoing large-volume TT, we formulated four questions regarding this impact. To answer these questions, we simulated right-sided PE in our virtual patient and studied changes in the pleural pressure in the ipsilateral hemithorax (Ppli) and lung volume during the respiratory cycle (exemplified by Ppli-V loops, where V is the volume of both lungs), airflows in the main bronchi, and alveolar O2 (PAO2) and CO2 (PACO2) partial pressures.Results: Simulations highlighted that: (a) mediastinal compliance critically affects hemidiaphragm work; (b) the 8-shaped Ppli-V loops are associated with hemidiaphragm inversion, where exhalation from the ipsilateral lung occurs during a part of both the inspiratory and expiratory phases, and vice versa; (c) pre-TT PAO2 may be elevated due to reduction of the tidal volume to end-expiratory lung volume ratio; and (d) pre-TT Ppli amplitudes during respiration can exceed post-TT values when mediastinal compliance is high.Conclusion: Our findings emphasize the significance of mediastinal compliance in pleural effusion physiology and suggest insignificant influence of the ipsilateral hemidiaphragm inverted due to large PE on arterial gas tensions. This study underscores the utility of virtual patient models for elucidating unexpected physiological behaviors and optimizing clinical interventions.