Zehui Yuan

Ms. Zehui Yuan

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XMXiaoyang Ma
Xiaoyang Ma
YWYongxin Wu
Yongxin Wu
XXXianyong Xiao
Xianyong Xiao
YWYing Wang
Ying Wang
ZYZehui Yuan
Zehui Yuan
ZGZesen Gui
Zesen Gui
A phasor measurement unit (PMU) is a basic tool for synchrophasor estimation in modern power systems. The large-scale integration of power electronic devices in modern power systems results in DC offset on the AC side. In addition, with the rapid development of high-voltage DC transmission projects, the decay time of the DC offset in the system has further increased, which severely affects the estimation accuracy of the M-class PMU. When DC offset and out-of-band interference (OOBI) such as interharmonics coexist, the errors in the time-frequency domain convolution and higher-order matrix inversion increase. The errors of the M-class PMUs are further amplified as a result. Existing methods are ineffective in addressing this challenge. To address this problem, this paper proposes an algorithm based on polynomial fitting and three-point interpolation. First, the iterative elimination concept is employed to restructure DC offset. The initial estimation of the synchrophasor is subsequently performed via linear Bessel interpolation. Finally, the conditional iterative optimization is used for the second estimation of the synchrophasor. The simulation scenarios are designed based on Standard IEC/IEEE 60255-118-1, and the results show that the proposed algorithm can accurately estimate with OOBI and DC offset.

2 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
ZYZehui Yuan
Zehui Yuan
ZLZheng Liao
Zheng Liao
HTHaiyan Tu
Haiyan Tu
YTYuxin Tu
Yuxin Tu
WLWei Li
Wei Li
To improve the detection speed for wide-frequency dense signals (WFDSs), a fast minimization algorithm (FMA) was proposed in this study. Firstly, this study modeled the WFDSs and performed a Taylor-series expansion of the sampled model. Secondly, we simplified the sampling model based on the augmented Lagrange multiplier (ALM) method and then calculated the augmented Lagrange function of the sampling model. Finally, according to the alternating minimization strategy, the Lagrange multiplier vector and the sparse block phasor in the function were iterated individually to realize the measurement of the original signal components. The results show that the algorithm improved the analysis accuracy of the WFDS by 35% to 46% on the IEEE C37.118.1a-2014 standard for the wide-frequency noise test, harmonic modulation test, and step-change test, providing a theoretical basis for the development of the P-class phasor measurement unit (PMU).

13 March 2026 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZGZesen Gui
Zesen Gui
QZQun Zhou
Qun Zhou
XMXiaoyang Ma
Xiaoyang Ma
ZLZheng Liao
Zheng Liao
ZYZehui Yuan
Zehui Yuan
With the large-scale integration of new energy sources into power grids, the level of disturbances in new power systems has gradually increased. The disturbances in the 9–150 kHz frequency band may exceed the limit values of the electromagnetic compatibility in the IEC 61000-2-2 standard. However, methods for measuring disturbances in this band are still under development. Currently, IEC SC77A/WG9 is developing a quasi-peak (QP) measurement method of disturbances in the 9–150 kHz band for the IEC 61000-4-30 standard. Therefore, this paper proposes a 9–150 kHz QP measurement method (compressed sensing–phase-locked loop, CS-PLL method) that conforms to the framework of the IEC 61000-4-30 standard. The phase-locked loop (PLL) disturbance tracking part of the method enables disturbance tracking with less computation, whereas frequency pre-estimation effectively shortens the PLL method adaptation process and reduces the measurement uncertainty at short window lengths. After simulation and experimental signal verification, the combination of frequency pre-estimation and the PLL method can achieve a measurement uncertainty of less than 5% in a 200 ms QP measurement window. This meets the measurement window length proposal of the IEC 61000-4-30 standard framework and the measurement uncertainty proposal for this frequency band.

26 May 2022 in Electronics
Verified
Journal Article
Open access
PDF file
YPYufei Pan
Yufei Pan
ZYZehui Yuan
Zehui Yuan
JZjiaoyu zheng
jiaoyu zheng
XMXiaoyang Ma
Xiaoyang Ma
Power quality monitoring equipment is inevitably faced with the problem of data loss and is vulnerable to the interference of noise or bad data. We propose a harmonic data recovery method that is based on graph clustering and non-negative matrix factorization (NMF) under multiple constraints. Compared with the existing harmonic data recovery methods, the proposed method can effectively recover lost data and it has a strong anti-interference ability, especially for the recovery of harmonic data with interference. In the recovery of data loss, noisy interference tests and bad data interference tests, the presented recovery algorithm has high accuracy within 60% for continuous missing data. In an environment with SNR = 50, this method has high recover reliability and accuracy within 15% for situations involving bad data interference.

18 May 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
ZYZehui Yuan
Zehui Yuan
XXXianyong Xiao
Xianyong Xiao
XMXiaoyang Ma
Xiaoyang Ma

1 January 2026 in IEEE Signal Processing Letters
Verified
Journal Article
Closed access
XMXiaoyang Ma
Xiaoyang Ma
ZLZijing Liu
Zijing Liu
ZYZehui Yuan
Zehui Yuan
XXXianyong Xiao
Xianyong Xiao
XLXIAOKANG LIU
XIAOKANG LIU
YWYongxin Wu
Yongxin Wu