In this paper, the eccentric compression test of seven specimens was conducted to explore the application possibility of recycled aggregate concrete (RAC) in L-shaped columns composed of concrete-filled steel tubes (CFST). The main parameter is the replacement ratio of recycled coarse aggregates (RCA), and an L-shaped column of composed hollow steel tubes was set as a control. The test results indicated that the bearing capacity and stiffness of the L-shaped column composed of RAC-filled steel tubes (RACFSTs) are better than those of the L-shaped column composed of hollow steel tubes. The compressive strength of concrete is reduced by 73.1% as the replacement ratio of RCA increases from 0 to 100%, while that of the column is merely reduced by 23.9%. The strength disadvantage of RAC is compensated by the confinement of steel tubes. Besides, the result of the eccentric compression test (80 mm eccentricity) was compared with the axial compression test (0 mm eccentricity). The increase in eccentricity reduced the bearing capacity and ductility due to additional bending moments. The finite element model (FEM) was established by software ANSYS to compare with the experimental results. The bearing capacity deviation of FEM is 4.23~6.56%. The parametric analysis was carried out to summarize the influence of parameters such as eccentricity, material strength, and steel tube thickness. With the increase of eccentricity, the bearing capacity of the RACFST decreases gradually. In engineering design, the bearing capacity of the RACFST can be improved by increasing the strength and thickness of the steel.
Owing to their lightness, high strength, flexibility, and design adaptability, cables have been extensively employed in architectural engineering. As cables are primary load-bearing components in long-span spatial structures, a profound understanding of their mechanical behavior is essential for structural design and safety evaluation. This paper presents a systematic review of the physical and mechanical properties of cables commonly used in building structures, offering reference data for key performance indicators. The mechanical responses and influencing factors pertaining to major types of cables—such as semi-parallel wire strand (SPWS), Galfan-coated steel strand (GSS), and full-locked coil wire rope (LCR)—are thoroughly examined. This review covers five critical aspects: fundamental cable characteristics, stress relaxation and creep, mechanical performance under high temperatures, corrosion-induced degradation, and post-fracture behavior after fatigue-induced wire breaks. It identifies key mechanical parameters, including elastic modulus, axial stiffness, bending stiffness, and the coefficient of thermal expansion. The degradation behavior of cables under high-temperature and corrosive conditions is examined, highlighting the superior corrosion resistance of LCR and GSS. Furthermore, the redistribution of stress and residual capacity after the rupturing of steel wires is elucidated. Based on recent studies, prospective directions are suggested to address current knowledge gaps and advance design strategies focused on durability and performance for forthcoming cable-supported structures.