Jiangtao Xu

Dr. Jiangtao Xu


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2021 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
JXJiangtao Xu
Jiangtao Xu
TGTongjun Guo
Tongjun Guo

1 March 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
JXJiangtao Xu
Jiangtao Xu
JXJiangtao Xu
Jiangtao Xu
Xinyu FanXinyu Fan
Xinyu Fan
AFAimin Fan
Aimin Fan

1 January 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
MHMaoyang Hu
Maoyang Hu
SCSiqin Chang
Siqin Chang
LLLiang Liu
Liang Liu
YXYaxuan Xu
Yaxuan Xu
JXJiangtao Xu
Jiangtao Xu

8 August 2019 in IEEE Access
Verified
Journal Article
Open access
TGTongjun Guo
Tongjun Guo
SCSiqin Chang
Siqin Chang
ZCZhiqiang Chen
Zhiqiang Chen
HHHangang Huang
Hangang Huang
JXJiangtao Xu
Jiangtao Xu
In order to realize fully flexible variable valve lift and improve the intake efficiency of the engine, a new electromagnetic valve-train (EMVT) was designed to replace the traditional CAM in the engine valve-train. However, as the durability of electromagnetic linear actuator (ELA) in the EMVT was lower than that of CAM, and there might be some problems during a long running time. This paper presented an improved online fault diagnosis method combining BP Neural Networks with Grey Relation Analysis (GRA) to analyze current signals, which could realize the monitoring, diagnosis of electromagnetic linear actuator faults and early warning so as to prevent unnecessary situations such as accidental cylinder stop of the engine. The results showed that this method had a high fault diagnosis rate, high speed, reliability and practicability.

1 April 2021 in Science Progress
Verified
Journal Article
Open access
PDF file
JXJiangtao Xu
Jiangtao Xu
TGTongjun Guo
Tongjun Guo
YFYong Feng
Yong Feng
MSMengxin Sun
Mengxin Sun
Previous studies have shown that increase compression ratio (CR) is an effective way to improve thermal efficiency of gasoline engine without changing the mechanical structure and working cycle, however, it is limited by engine knock when increasing the intake boosting under high load operation. This study aimed to solve the knock problem of gasoline engine with higher CR by application of Miller cycle, which can be implemented by either early or late intake valve closing (EIVC or LIVC). Therefore, in this paper, based on the engine with CR of 13.5 and electromagnetic valves train (EMVT), a comparative study was carried out to investigate the effects of EIVC and LIVC on engine performance, by theoretical modeling and calculation. The results show that, at high load, EIVC strategy is more preferred than LIVC owing to its lower total power consumption, which can improve the indicated mean effective pressure (IMEP) by 0.0371 bar, while enhance turbulence intensity and improve combustion. And at part load, the advantage for EIVC declines gradually, nevertheless, it can still sensitively adjust the EGR rate and thus reduce NOx. This results of quantitative analysis about two Miller cycles can provide valuable reference for engine designers and researchers.

12 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
JXJiangtao Xu
Jiangtao Xu
CLCheng Liu
Cheng Liu
XLXiaojun Liu
Xiaojun Liu
XSXiaoxiao Sun
Xiaoxiao Sun
YLYongjian Li
Yongjian Li
As a clean energy technology, air source heat pump (ASHP) technology has garnered increasing attention nowadays; however, the sharp decline in energy efficiency under low-temperature conditions remains a significant challenge impeding their widespread adoption. In this paper, in response to the demand under the Australian standard, mathematical modeling was carried out to explore the technical strategy for improving the performance of an ASHP; then, these strategies were evaluated by simulation calculation and experiment. The results show that, using frequency conversion, the coefficient of performance of the heat pump system (COP) reaches a maximum value of 2.48 when the frequency is 50 Hz, and the COP of the heat pump can reach a maximum value of 2.51 when the opening of the expansion valve is about 40%. Then, a new type of mixed refrigerant (R134a:R600a:R290) was proposed; the COP of the system reaches 2.502 when the mixture ratio is 1:6:3, which is an improvement of 6.61% compared to the use of only R134a. Finally, an analysis of the annual energy consumption under Australian weather conditions was conducted; the average COP is about 3.894, which is 6.3% higher than the result of using R134a. These results provide a theoretical basis for the development of a heat pump system that meets Australian standards.