Introduction: Hypoxia can cause central nervous system dysfunction and injury. Hypoxia is a particular risk during rebreather diving. Given its subtle symptom profile and its catastrophic consequences there is a need for reliable hypoxia monitoring. Electroencephalography (EEG) is being investigated as a real time monitor for multiple diving problems related to inspired gas, including hypoxia. Methods: A systematic literature search identified articles investigating the relationship between EEG changes and acute cerebral hypoxia in healthy adults. Quality of clinical evidence was assessed using the Newcastle-Ottawa scale. Results: Eighty-one studies were included for analysis. Only one study investigated divers. Twelve studies described quantitative EEG spectral power differences. Moderate hypoxia tended to result in increased alpha activity. With severe hypoxia, alpha activity decreased whilst delta and theta activities increased. However, since studies that utilised cognitive testing during the hypoxic exposure more frequently reported opposite results it appears cognitive processing might mask hypoxic EEG changes. Other analysis techniques (evoked potentials and electrical equivalents of dipole signals), demonstrated sustained regulation of autonomic responses despite worsening hypoxia. Other studies utilised quantitative EEG analysis techniques, (Bispectral index [BISTM], approximate entropy and Lempel-Ziv complexity). No change was reported in BISTM value, whilst an increase in approximate entropy and Lempel-Ziv complexity occurred with worsening hypoxia. Conclusions: Electroencephalographic frequency patterns change in response to acute cerebral hypoxia. There is paucity of literature on the relationship between quantitative EEG analysis techniques and cerebral hypoxia. Because of the conflicting results in EEG power frequency analysis, future research needs to quantitatively define a hypoxia-EEG response curve, and how it is altered by concurrent cognitive task loading.
30 June 2020 in Diving and Hyperbaric Medicine Journal
Introduction: In 2018 12 children and one adult were anaesthetised before being extricated through over a kilometre of flooded cave in Thailand. Full face dive masks (FFMs) putatively capable of maintaining constant positive airway pressure (CPAP) were employed. Here we describe the anaesthetic intervention and investigate the CPAP capability of the FFM. Methods: Pressure was measured inside and outside the Interspiro Divator FFM during 10 tidal and 10 vital capacity breaths in divers at the surface and submerged with the mask deployed on open-circuit scuba (10 divers); and a closed-circuit rebreather (five divers). Relative in-mask pressure was calculated as the difference between inside and outside pressures. We also measured the in-mask pressure generated by activation of the second stage regulator purge valve in open-circuit mode. Results: When submerged in open-circuit mode the mean relative in-mask pressure remained positive in normal tidal breathing (inhalation 0.6 kPa [95% CI 0.3–0.9]; exhalation 1.1 [0.8–1.4]) and vital capacity breathing (inhalation 0.8 [0.4–1.1]; exhalation 1.2 [0.9–1.4]). As expected, the relative in-mask pressure was predominantly negative when used on closed-circuit with back mounted counter-lungs due to a negative static lung load. Mean in-mask pressure during purge valve operation was 3.99 kPa (approximately equal to 40 cmH2O) (range: 2.56 to 5.3 kPa). Conclusions: The CPAP function of the Interspiro Divator FFM works well configured with open-circuit scuba. This may have contributed to the success of the Thailand cave rescue. Caution is required in generalising this success to other diving scenarios.
Background: Nitrous oxide produces non–γ-aminobutyric acid sedation and psychometric impairment and can be used as scientific model for understanding mechanisms of progressive cognitive disturbances. Temporal complexity of the electroencephalogram may be a sensitive indicator of these effects. This study measured psychometric performance and the temporal complexity of the electroencephalogram in participants breathing low-dose nitrous oxide. Methods: In random order, 20, 30, and 40% end-tidal nitrous oxide was administered to 12 participants while recording 32-channel electroencephalogram and psychometric function. A novel metric quantifying the spatial distribution of temporal electroencephalogram complexity, comprised of (1) absolute cross-correlation calculated between consecutive 0.25-s time samples; 2) binarizing these cross-correlation matrices using the median of all channels as threshold; (3) using quantitative recurrence analysis, the complexity in temporal changes calculated by the Shannon entropy of the probability distribution of the diagonal line lengths; and (4) overall spatial extent and intensity of brain complexity, was quantified by calculating median temporal complexity of channels whose complexities were above 1 at baseline. This region approximately overlay the brain’s default mode network, so this summary statistic was termed “default-mode-network complexity.” Results: Nitrous oxide concentration correlated with psychometric impairment (r = 0.50, P < 0.001). Baseline regional electroencephalogram complexity at midline was greater than in lateral temporal channels (1.33 ± 0.14 bits vs. 0.81 ± 0.12 bits, P < 0.001). A dose of 40% N2O decreased midline (mean difference [95% CI], 0.20 bits [0.09 to 0.31], P = 0.002) and prefrontal electroencephalogram complexity (mean difference [95% CI], 0.17 bits [0.08 to 0.27], P = 0.002). The lateral temporal region did not change significantly (mean difference [95% CI], 0.14 bits [−0.03 to 0.30], P = 0.100). Default-mode-network complexity correlated with N2O concentration (r = −0.55, P < 0.001). A default-mode-network complexity mixed-effects model correlated with psychometric impairment (r2 = 0.67; receiver operating characteristic area [95% CI], 0.72 [0.59 to 0.85], P < 0.001). Conclusions: Temporal complexity decreased most markedly in medial cortical regions during low-dose nitrous oxide exposures, and this change tracked psychometric impairment. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
Objective: Hyperbaric oxygenation is the accepted treatment for cerebral arterial gas embolism. Although earlier start of hyperbaric oxygenation is associated with better outcome, it is unknown how much delay can be tolerated before start of hyperbaric oxygenation. This study investigates the effect of hyperbaric oxygenation on cerebral function in swine when initiated 2 or 4 hours after cerebral arterial gas embolism. Design: Prospective interventional animal study. Setting: Surgical laboratory and hyperbaric chamber. Subjects: Twenty-two Landrace pigs. Interventions: Under general anesthesia, probes to measure intracranial pressure, brain oxygen tension (PbtO2), and brain microdialysis, and electrodes for electroencephalography were placed. The electroencephalogram (quantified using temporal brain symmetry index) was suppressed during 1 hour by repeated injection of air boluses through a catheter placed in the right ascending pharyngeal artery. Hyperbaric oxygenation was administered using U.S. Navy Treatment Table 6 after 2- or 4-hour delay. Control animals were maintained on an inspiratory oxygen fraction of 0.4. Measurements and Main Results: Intracranial pressure increased to a mean maximum of 19 mm Hg (SD, 4.5 mm Hg) due to the embolization procedure. Hyperbaric oxygenation significantly increased PbtO2 in both groups treated with hyperbaric oxygenation (mean maximum PbtO2, 390 torr; SD, 177 torr). There were no significant differences between groups with regard to temporal brain symmetry index (control vs 2-hr delay, p = 0.078; control vs 4-hr delay, p = 0.150), intracranial pressure, and microdialysis values. Conclusions: We did not observe an effect of hyperbaric oxygenation on cerebral function after a delay of 2 or 4 hours. The injury caused in our model could be too severe for a single session of hyperbaric oxygenation to be effective. Our study should not change current hyperbaric oxygenation strategies for cerebral arterial gas embolism, but further research is necessary to elucidate our results. Whether less severe injury benefits from hyperbaric oxygenation should be investigated in models using smaller amounts of air and clinical outcome measures.
20 December 2020 in Diving and Hyperbaric Medicine Journal
Introduction: Critical flicker fusion frequency (CFFF) has been used in various studies to measure the cognitive effects of gas mixtures at depth, sometimes with conflicting or apparently paradoxical results. This study aimed to evaluate a novel automatic CFFF method and investigate whether CFFF can be used to monitor gas-induced narcosis in divers. Methods: Three hyperbaric chamber experiments were performed: 1) Automated and manual CFFF measurements during air breathing at 608 kPa (n = 16 subjects); 2) Manual CFFF measurements during air and heliox breathing at sea level (101.3 kPa) and 608 kPa (n = 12); 3) Manual CFFF measurements during oxygen breathing at sea level, 142 and 284 kPa (n = 10). All results were compared to breathing air at sea level. Results: Only breathing oxygen at sea level, and at 284 kPa, caused a significant decrease in CFFF (2.5% and 2.6% respectively compared to breathing air at sea level. None of the other conditions showed a difference with sea level air breathing. Conclusions: CFFF did not significantly change in our experiments when breathing air at 608 kPa compared to air breathing at sea level pressure using both devices. Based on our results CFFF does not seem to be a sensitive tool for measuring gas narcosis in divers in our laboratory setting.
Divers commonly breathe air, containing nitrogen. Nitrogen under hyperbaric conditions is a narcotic gas. In dives beyond a notional threshold of 30 m depth (405 kPa) this can cause cognitive impairment, culminating in accidents due to poor decision making. Helium is known to have no narcotic effect. This study explored potential approaches to developing an electroencephalogram (EEG) functional connectivity metric to measure narcosis produced by nitrogen at hyperbaric pressures. Twelve human participants (five female) breathed air and heliox (in random order) at 284 and 608 kPa while recording 32-channel EEG and psychometric function. The degree of spatial functional connectivity, estimated using mutual information, was summarized with global efficiency. Air-breathing at 608 kPa (experienced as mild narcosis) caused a 35% increase in global efficiency compared to surface air-breathing (mean increase = 0.17, 95% CI [0.09–0.25], p = 0.001). Air-breathing at 284 kPa trended in a similar direction. Functional connectivity was modestly associated with psychometric impairment (mixed-effects model r2 = 0.60, receiver-operating-characteristic area, 0.67 [0.51–0.84], p = 0.02). Heliox breathing did not cause a significant change in functional connectivity. In conclusion, functional connectivity increased during hyperbaric air-breathing in a dose-dependent manner, but not while heliox-breathing. This suggests sensitivity to nitrogen narcosis specifically.