28 February 2022 in JMIR Human Factors
Background: Smart glasses have been gaining momentum as a novel technology because of their advantages in enabling hands-free operation and see-what-I-see remote consultation. Researchers have primarily evaluated this technology in hospital settings; however, limited research has investigated its application in prehospital operations. Objective: The aim of this study is to understand the potential of smart glasses to support the work practices of prehospital providers, such as emergency medical services (EMS) personnel. Methods: We conducted semistructured interviews with 13 EMS providers recruited from 4 hospital-based EMS agencies in an urban area in the east coast region of the United States. The interview questions covered EMS workflow, challenges encountered, technology needs, and users’ perceptions of smart glasses in supporting daily EMS work. During the interviews, we demonstrated a system prototype to elicit more accurate and comprehensive insights regarding smart glasses. Interviews were transcribed verbatim and analyzed using the open coding technique. Results: We identified four potential application areas for smart glasses in EMS: enhancing teleconsultation between distributed prehospital and hospital providers, semiautomating patient data collection and documentation in real time, supporting decision-making and situation awareness, and augmenting quality assurance and training. Compared with the built-in touch pad, voice commands and hand gestures were indicated as the most preferred and suitable interaction mechanisms. EMS providers expressed positive attitudes toward using smart glasses during prehospital encounters. However, several potential barriers and user concerns need to be considered and addressed before implementing and deploying smart glasses in EMS practice. They are related to hardware limitations, human factors, reliability, workflow, interoperability, and privacy. Conclusions: Smart glasses can be a suitable technological means for supporting EMS work. We conclude this paper by discussing several design considerations for realizing the full potential of this hands-free technology.
30 June 2020 in Diving and Hyperbaric Medicine Journal
Introduction: In 2018 12 children and one adult were anaesthetised before being extricated through over a kilometre of flooded cave in Thailand. Full face dive masks (FFMs) putatively capable of maintaining constant positive airway pressure (CPAP) were employed. Here we describe the anaesthetic intervention and investigate the CPAP capability of the FFM. Methods: Pressure was measured inside and outside the Interspiro Divator FFM during 10 tidal and 10 vital capacity breaths in divers at the surface and submerged with the mask deployed on open-circuit scuba (10 divers); and a closed-circuit rebreather (five divers). Relative in-mask pressure was calculated as the difference between inside and outside pressures. We also measured the in-mask pressure generated by activation of the second stage regulator purge valve in open-circuit mode. Results: When submerged in open-circuit mode the mean relative in-mask pressure remained positive in normal tidal breathing (inhalation 0.6 kPa [95% CI 0.3–0.9]; exhalation 1.1 [0.8–1.4]) and vital capacity breathing (inhalation 0.8 [0.4–1.1]; exhalation 1.2 [0.9–1.4]). As expected, the relative in-mask pressure was predominantly negative when used on closed-circuit with back mounted counter-lungs due to a negative static lung load. Mean in-mask pressure during purge valve operation was 3.99 kPa (approximately equal to 40 cmH2O) (range: 2.56 to 5.3 kPa). Conclusions: The CPAP function of the Interspiro Divator FFM works well configured with open-circuit scuba. This may have contributed to the success of the Thailand cave rescue. Caution is required in generalising this success to other diving scenarios.
1 June 2021 in JMIR Preprints
BACKGROUND Smart glasses have been gaining momentum as a novel technology because of their advantages in enabling hands-free operation and see-what-I-see remote consultation. Researchers have primarily evaluated this technology in hospital settings; however, limited research has investigated its application in prehospital operations. OBJECTIVE The aim of this study is to understand the potential of smart glasses to support the work practices of prehospital providers, such as emergency medical services (EMS) personnel. METHODS We conducted semistructured interviews with 13 EMS providers recruited from 4 hospital-based EMS agencies in an urban area in the east coast region of the United States. The interview questions covered EMS workflow, challenges encountered, technology needs, and users’ perceptions of smart glasses in supporting daily EMS work. During the interviews, we demonstrated a system prototype to elicit more accurate and comprehensive insights regarding smart glasses. Interviews were transcribed verbatim and analyzed using the open coding technique. RESULTS We identified four potential application areas for smart glasses in EMS: enhancing teleconsultation between distributed prehospital and hospital providers, semiautomating patient data collection and documentation in real time, supporting decision-making and situation awareness, and augmenting quality assurance and training. Compared with the built-in touch pad, voice commands and hand gestures were indicated as the most preferred and suitable interaction mechanisms. EMS providers expressed positive attitudes toward using smart glasses during prehospital encounters. However, several potential barriers and user concerns need to be considered and addressed before implementing and deploying smart glasses in EMS practice. They are related to hardware limitations, human factors, reliability, workflow, interoperability, and privacy. CONCLUSIONS Smart glasses can be a suitable technological means for supporting EMS work. We conclude this paper by discussing several design considerations for realizing the full potential of this hands-free technology.