Study Design. A cross-sectional population study of magnetic resonance imaging (MRI) changes. Objective. To examine the pattern and prevalence of lumbar spine MRI changes within a southern Chinese population and their relationship with back pain. Summary of Background Data. Previous studies on MRI changes and back pain have used populations of asymptomatic individuals or patients presenting with back pain and sciatica. Thus, the prevalence and pattern of intervertebral disc degeneration within the population is not known. Methods. Lumbar spine MRIs were obtained in 1043 volunteers between 18 to 55 years of age. MRI changes including disc degeneration, herniation, anular tears (HIZ), and Schmorl’s nodes were noted by 2 independent observers. Differences were settled by consensus. Disc degeneration was graded using Schneiderman’s classification, and a total score (DDD score) was calculated by the summation of the Schneiderman’s score for each lumbar level. A K-mean clustering program was used to group individuals into different patterns of degeneration. Results. Forty percent of individuals under 30 years of age had lumbar intervertebral disc degeneration (LDD), the prevalence of LDD increasing progressively to over 90% by 50 to 55 years of age. There was a positive correlation between the DDD score and low back pain. L5–S1 and L4–L5 were the most commonly affected levels. Apart from the usual patterns of degeneration, some uncommon patternsof degeneration were identified, comprising of subjects with skip level lesions (intervening normal levels) and isolated upper or mid lumbar degeneration. Conclusion. LDD is common, and its incidence increases with age. In a population setting, there is a significant association of LDD on MRI with back pain.
Magnesium and its alloys may potentially be applied as degradable metallic materials in orthopaedic implantations due to their degradability and resemblance to human cortical bone. However, the high corrosion rate and accumulation of hydrogen gas upon degradation hinders its clinical application. In this study, we adopt a new approach to control the corrosion rate by coating a controllable polymeric membrane fabricated by polycaprolactone and dichloromethane onto magnesium alloys, in which the pore size was controlled during the manufacturing process. The addition of the polymeric membrane was found to reduce the degradation rate of magnesium, and the bulk mechanical properties were shown to be maintained upon degradation. The in-vitro studies indicated good cytocompatibility of eGFP and SaOS-2 osteoblasts with the polymer-coated samples, which was not observed for the uncoated samples. The in-vivo study indicated that the uncoated sample degraded more rapidly than that of the polymer-coated samples. Although new bone formation was found on both samples, as determined by Micro-CT, higher volumes of new bone were observed on the polymer-coated samples. Histological analysis indicated no inflammation, necrosis or hydrogen gas accumulation on either of the samples during degradation. Collectively, these data suggest that the use of polymeric membrane may be potentially applied for future clinical use.
Scoliosis in skeletally immature children is often treated by implantation of a rod to straighten the spine. Rods can be distracted (lengthened) as the spine grows, but patients need many invasive operations under general anaesthesia. Such operations are costly and associated with negative psychosocial outcomes. We assessed the effectiveness and safety of a new magnetically controlled growing rod (MCGR) for non-invasive outpatient distractions. We implanted the MCGR in five patients, two of whom have now reached 24 months' follow-up. Each patient underwent monthly outpatient distractions. We used radiography to measure the magnitude of the spinal curvature, rod distraction length, and spinal length. We assessed clinical outcome by measuring the degree of pain, function, mental health, satisfaction with treatment, and procedure-related complications. In the two patients with 24 months' follow-up, the mean degree of scoliosis, measured by Cobb angle, was 67° (SD 10°) before implantation and 29° (4°) at 24 months. Length of the instrumented segment of the spine increased by a mean of 1·9 mm (0·4 mm) with each distraction. Mean predicted versus actual rod distraction lengths were 2·3 mm (1·2 mm) versus 1·4 mm (0·7 mm) for patient 1, and 2·0 mm (0·2 mm) and 2·1 mm (0·7 mm) versus 1·9 mm (0·6 mm) and 1·7 mm (0·8 mm) for patient 2's right and left rods, respectively. Throughout follow-up, both patients had no pain, had good functional outcome, and were satisfied with the procedure. No MCGR-related complications were noted. The MCGR procedure can be safely and effectively used in outpatient settings, and minimises surgical scarring and psychological distress, improves quality of life, and is more cost-effective than is the traditional growing rod procedure. The technique could be used for non-invasive correction of abnormalities in other disorders. Ellipse Technologies.