Smrutiranjan Nayak

Dr. Smrutiranjan Nayak

Electrical Engineering, Siksha O Anusandhan University, Bhubaneswar, India
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
SNSmrutiranjan Nayak
Smrutiranjan Nayak
SKSanjeeb Kumar Kar
Sanjeeb Kumar Kar
SDSubhransu Sekhar Dash
Subhransu Sekhar Dash
In continually increasing area and structure of modern power system having burden demand uncertainties, the use of knowledgeable and vigorous frequency power strategy is essential for the satisfactory functioning of the Power system. A combined fuzzy proportional-integral-derivative (CFPID) controller is suggested for frequency supervision of the power system. To optimize the controller parameters, a review of sine and cosine work adjusted improved whale optimization algorithm (SCiWOA) has been utilized. The next practical application of power-system frequency control is performed by designing a CFPID controller using the proposed SCiWOA technique for a smart grid system having inexhaustible sources like sun oriented, wind, photovoltaic and capacity gadgets like a battery, flywheel just as module electric vehicles. The first advantages of the SCiWOA tuned CFPID controller over hybrid-particle-swarm-optimization and pattern-search (hPSO-PS) adjusted fuzzy proportional-integral (FPI) controller, hybrid bacterial foraging optimization algorithm-particle swarm optimization (hBFOA-PSO) adjusted proportional-integral (PI) controller, genetic algorithm (GA) tuned proportional and integral (PI) controller, BFOA adjusted PI controller, jaya algoritm (JA) tuned PID with derivative filter (PIDN) controller and teaching learning based optimization (TLBO) tuned proportional-integral-derivative (PID) controller are demonstrated for the two-area non-reheat thermal power system. The second advantages of the SCiWOA tuned CFPID controller over artificial-bee-colony (ABC) tuned PID controller, SOSA tuned PID controller and Firefly algorithm (FA) tuned PID controller are demonstrated for two-area reheat thermal power system. It is seen that SCiWOA based CFPID controller is more effective in controlling the recurrence comparative with PID regulator.

27 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
SNSmrutiranjan Nayak
Smrutiranjan Nayak
SKSanjeeb Kumar Kar
Sanjeeb Kumar Kar
SDSubranhsu Sekhar Dash
Subranhsu Sekhar Dash
Pradeep VishnuramPradeep Vishnuram
Pradeep Vishnuram
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
Benedetto NastasiBenedetto Nastasi
Benedetto Nastasi
In the present study, an Enhanced SSA (ESSA) has been proposed where the parameter of the SSA technique, which balances the exploration and exploitation phases, has been modified. Additionally, the variable scaling factor is engaged to regulate the salp’s position during the search procedure to minimize the random movement of salps. To demonstrate the effectiveness of the enhanced SSA (ESSA), a set of multimodal test functions are engaged. The statistical outcomes demonstrate that ESSA profits from local optima evasion and quick convergence speed, which aids the proposed ESSA algorithm to outclass the standard SSA and other recent algorithms. The fair analysis displays that ESSA delivers very promising results and outclass current methods. Next, frequency control of power systems is executed by designing a Combined Fuzzy PID (CFPID) controller with the projected ESSA method. Next, a Partially Distributed CFPID (PD-CFPID) controller is designed for a distributed power system (DPS). It is shown that the ESSA method outclasses the SSA method in engineering problems. It is also noted that the ESSA-based PD-CFPID scheme has become more operative in monitoring the frequency than similar structured centralized fuzzy PID (CFPID) as well as PID controller. Finally, the outcomes of the PD-CFPID controller are equated with CFPID and PID for various uncertain situations to validate the benefit of the proposed control approach.

30 April 2025 in Indian Journal of Community Health
Verified
Journal Article
Open access
PDF file
SRSurya Prakash Routray
Surya Prakash Routray
SNSmrutiranjan Nayak
Smrutiranjan Nayak
IDIpsita Debata
Ipsita Debata
PPPrem Sagar Panda
Prem Sagar Panda
Introduction: The burden of TB is increased by delays in diagnosis and treatment, which are frequently brought on by inefficiencies in the patient and health system. Reducing mortality and transmission rates requires early detection and treatment. Objectives: This study aimed to estimate patient and health system delays among new pulmonary TB patients in Khordha district, Odisha. Methodology: A community-based, cross-sectional study was conducted among 420 pulmonary TB patients registered under the NTEP between June 2022 and July 2024. Multistage cluster sampling was used to select participants. Data on delays were collected using a semi-structured, pre-validated questionnaire. Statistical analysis, including chi-square tests, was performed using SPSS version 21. Results: 50.47% of patients experienced diagnostic delays longer than 15 days, and 8.8% of patients experienced delays longer than 14 days. 6.19% experienced treatment delays longer than seven days. Long-term delays were substantially correlated with factors like self-medication, trips to traditional healers, female gender, and age >30 years. Conclusion: Due to delays caused by systemic and sociodemographic factors, timely TB diagnosis and treatment are still difficult to achieve. Effective TB control requires addressing these through focused awareness efforts, early referrals, and reducing inefficiencies in the health system.

29 June 2021
Verified
Conference Paper
Closed access
SNSmrutiranjan Nayak
Smrutiranjan Nayak
SDSubhransu Sekhar Dash
Subhransu Sekhar Dash
SKSanjeeb Kumar Kar
Sanjeeb Kumar Kar
The uncertain nature of renewable sources and load demand makes modern power systems highly complex and causes the frequency fluctuations. This research presents a maiden application of an Improved Sunflower Optimization Algorithm (ISFO) technique tuned Adaptive Type-2 Fuzzy PID (AT2FPID) structurefor frequency regulation of hybrid distributed power systems integrated with renewable sources. Initially, PID controller is considered and the dominance of ISFO over Sunflower Optimization Algorithm (SFO), Genetic Algorithm (GA) and Differential Evolution (DE) has been established. Performance comparison is carried out by assessing overshoots, undershoots and various integral errors due to Step Load Perturbations (SLPs) in each area. In the next stage, AT2FPID controller is considered and its supremacy to control the system frequency is demonstrated by comparing with Type-2 Fuzzy PID (T2FPID), Type-1 Fuzzy PID (T1FPID) and PID controllers.

9 August 2023
Verified
Conference Paper
Closed access
AHAhmad Houkan
Ahmad Houkan
ASAshwin Kumar Sahoo
Ashwin Kumar Sahoo
SNSmrutiranjan Nayak
Smrutiranjan Nayak
After World War II, India emerged as one of the world's largest industrial powers, opening its political and economic influence. The Fifth Industrial Revolution is the next industrial revolution, and its goal is to harness human experts in cooperation with smart machines and robots, to obtain manufacturing with higher resource efficiency and easier use compared to the Fourth Industrial Revolution. It is expected that the focus will be on the human side, sustainability, and the environment. This paper looks at the industrial policy in India, emphasizing the continuous coordinating role of the government in various fields and that India will be one of the world's most trends towards investment and a suitable environment to keep pace with the latest industrial transformations. We aim to present a vision of the fifth industry, its applications, the techniques used, and the importance of developing countries in this field.

1 December 2023 in Medical Journal Armed Forces India
Verified
Journal Article
Closed access
MMMedha Mathur
Medha Mathur
AVAnjana Verma
Anjana Verma
NMNavgeet Mathur
Navgeet Mathur
DKDewesh Kumar
Dewesh Kumar
JMJitendra Kumar Meena
Jitendra Kumar Meena
PPPiyushkumar Parmar
Piyushkumar Parmar