Yeseul Park

Dr. Yeseul Park


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
JSJeonghyun Song
Jeonghyun Song
SESeongyong Eom
Seongyong Eom
JLJaeseung Lee Lee
Jaeseung Lee Lee
YCYoungshin Chu
Youngshin Chu
JKJAE WON KIM
JAE WON KIM
YPYeseul Park
Yeseul Park
R134a, a vehicle refrigerant used in the vehicle heat pump system, is regulated according to the Montreal Protocol. Refrigerants such as R1234yf, R744, and R290 in vehicle heat pump systems are being investigated to identify their alternatives. Because developing a new system exclusively for new refrigerants is costly, an empirical test was conducted on the R1234yf refrigerant in a heat pump system designed for the R134a refrigerant in an actual vehicle system. The heating, cooling, and battery-cooling modes were tested for the amount of refrigerant charge, and operability tests were conducted for the compressor load; heating, ventilation, air conditioning (HVAC) air flow rate; coolant temperature; and flow rate of each mode. The optimal refrigerant charge in heating mode was 0.7 kg, and the optimal refrigerant charge in the cooling and battery-cooling modes was 0.9 kg. To yield the highest coefficient of performance of the system, the compressor load was 50%, the HVAC fan was 12 V, and the coolant flow rate was 10 LPM. The most efficient system operation was possible at a coolant temperature of 30 °C in the cooling and heating modes and at 20 °C in battery-cooling mode.

1 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
MYMyeongsu Yoon
Myeongsu Yoon
MCMinsung Choi
Minsung Choi
KKKijoong Kang
Kijoong Kang
COChaeho Oh
Chaeho Oh
YPYeseul Park
Yeseul Park
GCGyeong Min Choi
Gyeong Min Choi
This study analyzed factors that influence the ignition delay characteristics of n-heptane/methane-blended fuel. The effects of chemical species, exhaust gas recirculation rate, compression ratio, cool/hot flames, and combustion chamber conditions (temperature, pressure, and O2 concentration) were determined and analyzed using CHEMKIN Pro. The experiment conditions for verification were 550–1000 K at 15 bar with 50% H2/50% CH4 fuel. The main combustion reactions were confirmed through reactivity analysis and sensitivity analysis on the ignition delay time. The ignition delay time at 14.7% O2 concentration was significantly higher than that at 21% O2 concentration by more than 30%. In addition, a higher ratio of methane in the blended fuel increased the ignition delay time as a result of methane dehydrogenation, delaying the ignition of heptane.

1 January 2022 in Energy
Verified
Journal Article
Closed access
MCMinsung Choi
Minsung Choi
YPYeseul Park
Yeseul Park
KDKaiwen Deng
Kaiwen Deng
XLXinzhuo Li
Xinzhuo Li
KKKibeom Kim
Kibeom Kim
GCGyeong Min Choi
Gyeong Min Choi

28 August 2023 in Heliyon
Verified
Journal Article
Open access
JKJunsung Kim
Junsung Kim
CACheolhee Ahn
Cheolhee Ahn
HAHyeongjin Ahn
Hyeongjin Ahn
JPJiwon Park
Jiwon Park
WPWarngyu Park
Warngyu Park
YPYeseul Park
Yeseul Park
In confined environments such as aircraft, an increase in mass impacts the overall system’s performance, thus requiring sophisticated management. To verify whether the performance characteristics of fire extinguishing systems used in aircraft are satisfied, in this study was built a 1:1 scale test model. We examined the influence of the initial charge state and nozzles. Further, it measured the pressure inside the pipelines and vessels where multiple nozzles are installed to identify the flow and diffusivity characteristics of HFC-125 inside the pipelines and vessels. At a charging ratio of 54%, the initial pressure drop was smaller, and the lowest pressure before the bubble release point appeared 0.26 s later than when the charging ratio was 76%. The average pressure of each nozzle was 275.8 kPa higher under a charging ratio of 54% than 76% and increased further when the average concentration change was 54%, indicating that diffusivity increased. Although improvements occurred according to the charging ratio, the improvements according to the HFC-125 charging mass were more significant.

28 January 2023 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
HKHyunseok Kim
Hyunseok Kim
BOBeen Oh
Been Oh
SNSangkyung Na
Sangkyung Na
SSSanghoon Song
Sanghoon Song
HKHyun Kim
Hyun Kim
GCGyeong Min Choi
Gyeong Min Choi