R134a, a vehicle refrigerant used in the vehicle heat pump system, is regulated according to the Montreal Protocol. Refrigerants such as R1234yf, R744, and R290 in vehicle heat pump systems are being investigated to identify their alternatives. Because developing a new system exclusively for new refrigerants is costly, an empirical test was conducted on the R1234yf refrigerant in a heat pump system designed for the R134a refrigerant in an actual vehicle system. The heating, cooling, and battery-cooling modes were tested for the amount of refrigerant charge, and operability tests were conducted for the compressor load; heating, ventilation, air conditioning (HVAC) air flow rate; coolant temperature; and flow rate of each mode. The optimal refrigerant charge in heating mode was 0.7 kg, and the optimal refrigerant charge in the cooling and battery-cooling modes was 0.9 kg. To yield the highest coefficient of performance of the system, the compressor load was 50%, the HVAC fan was 12 V, and the coolant flow rate was 10 LPM. The most efficient system operation was possible at a coolant temperature of 30 °C in the cooling and heating modes and at 20 °C in battery-cooling mode.
The purity of hydrogen finally purified in the hydrogen purification process system is greatly influenced by the uniformity of the purification temperature of the dry tower. An in-house code that can be easily used by field designers has been developed to predict the capacity of the appropriate heat source and the time to reach the temperature of the dry tower. A code was developed to predict unsteady heat transfer using VBA. To verify the developed code, a grid independence test was performed, and finally, calculations were performed for two cases. The factor that influences the temperature history over time is the precise determination of values for the density, specific heat, and thermal conductivity of the heterogeneous materials composing the dryer tower. It was confirmed that the developed code well describes the actual test trend data of the regeneration process of adsorption and desorption, and it is judged that the code developed in the design process of various capacity systems will be effectively applied to the heat capacity calculation in the future.
Although the production of high-quality hydrogen from electrolysis systems is essential, research in this area is limited. In this study, we investigate the effect of operating conditions on the change in oxygen concentration through computational analysis for optimizing the deoxo chamber of a water electrolysis system. The test results of the water electrolysis system are simulated, and the oxygen concentration of the deoxo chamber is calculated through computational fluid dynamics analysis according to various conditions, such as the pressure, temperature, and flow rate. The O2 removal performance is significantly affected by the operating pressure and temperature, with an increase in both leading to a decrease in the O2 concentration in the water electrolysis system. Furthermore, we confirm that the change in the flow rate into the chamber has a minor effect on the change in the oxygen removal performance when the inlet flow rate was 1–1.5 kg/h and the length diameter ratio of the chamber is 38.4.
In order to save the time and material costs associated with refrigeration system performance evaluations, a reduced-order model (ROM) using highly accurate numerical analysis results and some experimental values was developed. To solve the shortcomings of these traditional methods in monitoring complex systems, a simplified reduced-order system model was developed. To evaluate the performance of the refrigeration system compressor, the temperature of several points in the system where the compressor actually operates was measured, and the measured values were used as input values for ROM development. A lot of raw data to develop a highly accurate ROM were acquired from a VRF system installed in a building for one year, and in this study, specific operating conditions were selected and used as input values. In this study, the ROM development process can predict the performance of compressors used in air conditioning systems, and the research results on optimizing input data required for ROM generation were observed. The input data are arranged according to the design of experiments (DOE), and the accuracy of ROM according to data arrangement is compared through the experiment results.
30 June 2024 in Transactions of the Korean hydrogen and new energy society
Hydrogen fuel cell buses (HFCBs) offer a promising zero-emission solution for sustainable public transportation. However, the high energy consumption of auxiliary systems, particularly heating, ventilation and air conditioning (HVAC), significantly impacts overall vehicle efficiency by increasing hydrogen consumption. This study investigates the influence of the HVAC load on the energy efficiency of hydrogen fuel cell buses under different driving conditions and seasonal ambient temperatures. Using a MATAB/Simulink-based simulation framework, the interaction between the fuel cell system, battery dynamics, and HVAC operation is modeled to quantify energy consumption under urban, highway and mixed driving conditions. Simulation was conducted at 7 °C and 35 °C with varying HVAC load levels of 50% and 100% to represent harsh winter and summer conditions. Results demonstrated that HVAC operation can account for a substantial portion of total energy consumption, reducing the vehicle range and fuel cell efficiency.