Akihiko Tsukahara

Dr. Akihiko Tsukahara

Tokyo Denki University, Saitama, Japan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2020 in Electronics and Communications in Japan
Verified
Journal Article
Closed access
PDF file
ATAkihiko Tsukahara
Akihiko Tsukahara
YAYuki Anzai
Yuki Anzai
KTKeita Tanaka
Keita Tanaka
YUYoshinori Uchikawa
Yoshinori Uchikawa

18 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
KTKeita Tanaka
Keita Tanaka
ATAkihiko Tsukahara
Akihiko Tsukahara
HMHiroki Miyanaga
Hiroki Miyanaga
STShoji Tsunematsu
Shoji Tsunematsu
.K.Takanori Kato
.Takanori Kato
HSHiromu Sakai
Hiromu Sakai
Magnetoencephalography (MEG) systems are advanced neuroimaging tools used to measure the magnetic fields produced by neuronal activity in the human brain. However, they require significant amounts of liquid helium to keep the superconducting quantum interference device (SQUID) sensors in a stable superconducting state. Additionally, MEG systems must be installed in a magnetically shielded room to minimize interference from external magnetic fields. We have developed an advanced MEG system that incorporates a superconducting magnetic shield and a zero-boil-off system. This system overcomes the typical limitations of traditional MEG systems, such as the frequent need for liquid helium refills and the spatial constraints imposed by magnetically shielded rooms. To validate the system, we conducted an evaluation using signal source estimation. This involved a phantom with 50 current sources of known location and magnitude under active zero-boil-off conditions. Our evaluations focused on the precision of the magnetic field distribution and the quantification of estimation errors. We achieved a consistent magnetic field distribution that matched the source current, maintaining an estimation error margin within 3.5 mm, regardless of the frequency of the signal source current. These findings affirm the practicality and efficacy of the system.

10 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ATAkihiko Tsukahara
Akihiko Tsukahara
TYTomiharu Yamaguchi
Tomiharu Yamaguchi
YTYuho Tanaka
Yuho Tanaka
AUAkinori Ueno
Akinori Ueno
In principle, the recently proposed capacitive-coupling impedance spectroscopy (CIS) has the capability to acquire frequency spectra of complex electrical impedance sequentially on a millisecond timescale. Even when the measured object with time-varying unknown resistance Rx is capacitively coupled with the measurement electrodes with time-varying unknown capacitance Cx, CIS can be measured. As a proof of concept, this study aimed to develop a prototype that implemented the novel algorithm of CIS and circuit parameter estimation to verify whether the frequency spectra and circuit parameters could be obtained in milliseconds and whether time-varying impedance could be measured. This study proposes a dedicated processor that was implemented as field-programmable gate arrays to perform CIS, estimate Rx and Cx, and their digital-to-analog conversions at a certain time, and to repeat them continually. The proposed processor executed the entire sequence in the order of milliseconds. Combined with a front-end nonsinusoidal oscillator and interfacing circuits, the processor estimated the fixed Rx and fixed Cx with reasonable accuracy. Additionally, the combined system with the processor succeeded in detecting a quick optical response in the resistance of the cadmium sulfide (CdS) photocell connected in series with a capacitor, and in reading out their resistance and capacitance independently as voltages in real-time.

25 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NPNina Pilyugina
Nina Pilyugina
ATAkihiko Tsukahara
Akihiko Tsukahara
KTKeita Tanaka
Keita Tanaka
The aim of this study was to find an efficient method to determine features that characterize octave illusion data. Specifically, this study compared the efficiency of several automatic feature selection methods for automatic feature extraction of the auditory steady-state responses (ASSR) data in brain activities to distinguish auditory octave illusion and nonillusion groups by the difference in ASSR amplitudes using machine learning. We compared univariate selection, recursive feature elimination, principal component analysis, and feature importance by testifying the results of feature selection methods by using several machine learning algorithms: linear regression, random forest, and support vector machine. The univariate selection with the SVM as the classification method showed the highest accuracy result, 75%, compared to 66.6% without using feature selection. The received results will be used for future work on the explanation of the mechanism behind the octave illusion phenomenon and creating an algorithm for automatic octave illusion classification.