Hyunwoo Cho

Dr. Hyunwoo Cho

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
HCHyunwoo Cho
Hyunwoo Cho
DKDongju Kim
Dongju Kim
SCSunyeob Chang
Sunyeob Chang
JKJinbum Kang
Jinbum Kang
YYYangmo Yoo
Yangmo Yoo

26 April 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
HCHyunwoo Cho
Hyunwoo Cho
ISIlseob Song
Ilseob Song
JJJihun Jang
Jihun Jang
YYYangmo Yoo
Yangmo Yoo
Bladder volume assessments are crucial for managing urinary disorders. Ultrasound imaging (US) is a preferred noninvasive, cost-effective imaging modality for bladder observation and volume measurements. However, the high operator dependency of US is a major challenge due to the difficulty in evaluating ultrasound images without professional expertise. To address this issue, image-based automatic bladder volume estimation methods have been introduced, but most conventional methods require high-complexity computing resources that are not available in point-of-care (POC) settings. Therefore, in this study, a deep learning-based bladder volume measurement system was developed for POC settings using a lightweight convolutional neural network (CNN)-based segmentation model, which was optimized on a low-resource system-on-chip (SoC) to detect and segment the bladder region in ultrasound images in real time. The proposed model achieved high accuracy and robustness and can be executed on the low-resource SoC at 7.93 frames per second, which is 13.44 times faster than the frame rate of a conventional network with negligible accuracy drawbacks (0.004 of the Dice coefficient). The feasibility of the developed lightweight deep learning network was demonstrated using tissue-mimicking phantoms.

5 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HCHyunwoo Cho
Hyunwoo Cho
EKEunwoo Kil
Eunwoo Kil
JJJihun Jang
Jihun Jang
JKJinbum Kang
Jinbum Kang
ISIlseob Song
Ilseob Song
YYYangmo Yoo
Yangmo Yoo
Inspecting the sealing integrity of lead tabs is an important means of ensuring the reliability and safety of pouch-type lithium-ion (Li-ion) batteries with a thin multi-layered aluminum (Al) laminated film. This paper presents a new air-coupled ultrasonic non-destructive testing (NDT) inspection method based on leaky Lamb wave transmission; and reception for evaluating the sealing integrity between the lead tab and the Al pouch film. The proposed method uses the critical incidence angle between the air and the layer with the fastest Lamb wave velocity to maximize the signal-to-noise ratio in the through-transmission mode. To determine the critical incidence angle, phantom experiments with two test pieces (i.e., an Al tab and an Al tab sealed with an Al pouch film) are conducted. In addition, 2D scans are performed at various incidence angles for an inhouse pouch-type Li-ion battery with a 1-mm-wide foreign material inserted as a defect. At the critical incidence angle (i.e., 22°), the proposed air-coupled ultrasonic NDT method in through-transmission mode successfully identifies the shape and location of the defect through c-scan image reconstruction. These preliminary results indicate that the proposed air-coupled ultrasonic NDT method with leaky Lamb waves can be used to inspect the sealing integrity of Li-ion pouch batteries in dry test conditions.

22 May 2025 in Ultrasonics
Verified
Journal Article
Closed access
HCHyunwoo Cho
Hyunwoo Cho
JLJaebin Lee
Jaebin Lee
SPSeongjun Park
Seongjun Park
YYYangmo Yoo
Yangmo Yoo

2 May 2025 in IEEE Access
Verified
Journal Article
Open access
DPDaehyun Park
Daehyun Park
HCHyunwoo Cho
Hyunwoo Cho
ISIlseob Song
Ilseob Song
JJJihun Jang
Jihun Jang
YYYangmo Yoo
Yangmo Yoo
Accurate measurement of bladder volume is critical for the effective management of urinary diseases. Among the available modalities, ultrasound imaging is favored due to its cost-effectiveness, non-ionizing nature, and capability to provide real-time bladder volume measurements. To enhance convenience in clinical practice, ultrasound bladder scanners have been developed and adopted in various settings. However, wobbling probe devices present significant limitations, including their inability to provide real-time images, the requirement for pre-scan alignment to ensure precise probe positioning, and the necessity for multiple volume estimations to achieve measurement accuracy. Additionally, conventional image-based estimations utilizing standard ultrasound machines or recently developed bladder scanners face challenges related to the use of shape coefficients. These methods typically rely on two image planes, which fail to fully capture the bladder’s shape, resulting in considerable errors in volume estimation when compensating for shape with coefficients. To overcome these limitations, this study proposes a novel automated bladder volume measurement technique that employs a T-shaped cross-array ultrasound probe in conjunction with free-hand motion-based 3D reconstruction. The T-shaped cross-array enables the simultaneous acquisition of sagittal and transverse view images of the bladder. By moving the probe at the suprapubic region, continuously acquired sagittal images can be combined into a 3D volume, with motion compensation achieved via the transverse images. Consequently, the proposed method can accurately reconstruct the entire bladder and measure its volume without the need for shape correction coefficients, while also reducing errors associated with ultrasound probe positioning. The proposed methodology was validated through phantom experiments simulating both spherical and irregular bladder shapes. The results demonstrated an error rate ranging from -8.8% to +5.6% when compared to the ground truth, indicating the method’s high accuracy. These results indicate that the proposed method, in conjunction with the developed array and system, has the potential to reduce the necessity for catheterization in clinical settings and enhance clinical decision-making.

6 February 2026 in Ultrasonics
Verified
Journal Article
Closed access
JKJinbum Kang
Jinbum Kang
SPSeongjun Park
Seongjun Park
ELEonho Lee
Eonho Lee
HCHyunwoo Cho
Hyunwoo Cho
KKKangsik Kim
Kangsik Kim
YYYangmo Yoo
Yangmo Yoo