Ultrafast power Doppler imaging based on coherent compounding (UPDI-CC) has become a promising technique for microvascular imaging due to its high sensitivity to slow blood flows. However, since this method utilizes a limited number of plane wave or diverging wave transmissions for high-frame rate imaging, it suffers from degraded image quality because of low contrast resolution. In this paper, an ultrafast power Doppler imaging method based on a nonlinear compounding framework, called frame-multiply-and-sum (UPDI-FMAS), is proposed to improve contrast resolution. In UPDI-FMAS, unlike conventional channel-domain delay-multiply-and-sum (DMAS) beamforming, the signal coherence are estimated based on autocorrelation function over plane wave angle frames. To avoid phase distortion of blood flow signals during the autocorrelation process, clutter filtering is preferentially applied to individual beamformed plane wave data set. Therefore, only coherent blood flow signals are emphasized while incoherent background noise is suppressed. The performance of the UPDI-FMAS was evaluated with simulation, phantom and in vivo studies. For the simulation and phantom studies with a constant laminar flow, the UPDI-FMAS showed improvements in the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) to those of UPDI-CC, i.e., over 10 dB and 7 dB for 13 plane waves, respectively, and the performances were improved as the number of plane waves increased. Moreover, the enhancement of the image quality due to the increased SNR and CNR in UPDI-FMAS was more clearly depicted with the in vivo study, in which a human kidney and a tumor-bearing mouse were evaluated. These results indicate that the FMAS compounding can improve image quality of UPDI for microvascular imaging without loss of temporal resolution.
18 September 2019 in IEEE Transactions on Biomedical Engineering
Ultrafast ultrasound imaging provides great opportunities for very high frame rate applications, such as shear wave elastography and microvascular imaging. However, ultrafast imaging with curved array transducers remains challenging in terms of element directivity and a limited field-of-view (FOV) for a fully synthetic area. In this paper, a wide FOV ultrafast curved array imaging method based on diverging wave transmissions is presented for high frame rate abdominal ultrasound applications. For this method, a theoretical model for a diverging wave solution based on a virtual point source originating from a circular line is proposed, and the FOV and element directivity are analyzed by this model. Furthermore, an integrated model for plane wave and diverging wave imaging along the location of the virtual point source is derived. The proposed method was evaluated with simulation, phantom, and in vivo studies. In the simulation and phantom studies, the image quality (i.e., spatial resolution, cystic resolution, and contrast-to-noise ratio), and effective FOV were assessed. For the in vivo study, a preliminary result from abdominal microvascular imaging, where diverging wave excitation was utilized to depict the vasculature, was also presented. In the renal cortex microvessels, the diverging wave imaging yielded a higher signal-to-clutter ratio value than the plane wave imaging, i.e., 6.35 vs. 4.26 dB, due to the wider synthetic field. These studies demonstrated that the proposed ultrafast curved array imaging technique based on diverging wave excitation allowed for an extended FOV with high spatiotemporal resolution.
Noninvasive monitoring of blood flow in the carotid artery is important for evaluating not only cerebrovascular but also cardiovascular diseases. In this paper, a wireless neckband ultrasound Doppler system, in which two 2.5-MHz ultrasonic sensors are utilized for acquiring Doppler signals from both carotid arteries, is presented for continuously evaluating blood flow dynamics. In the developed wireless neckband Doppler system, the acquired Doppler signals are quantized by 14-bit analog-to-digital-converters running at 40 MHz, and pre-processing operations (i.e., demodulation and clutter filtering) are performed in an embedded field programmable gate array chip. Then, these data are transferred to an external smartphone (i.e., Galaxy S7, Samsung Electronics Co., Suwon, Korea) via Bluetooth 2.0. Post-processing (i.e., Fourier transform and image processing) is performed using an embedded application processor in the smartphone. The developed carotid neckband Doppler system was evaluated with phantom and in vivo studies. In a phantom study, the neckband Doppler system showed comparable results with a commercial ultrasound machine in terms of peak systolic velocity and resistive index, i.e., 131.49 ± 3.97 and 0.75 ± 0.02 vs. 131.89 ± 2.06 and 0.74 ± 0.02, respectively. In addition, in the in vivo study, the neckband Doppler system successfully demonstrated its capability to continuously evaluate hemodynamics in both common carotid arteries. These results indicate that the developed wireless neckband Doppler system can be used for continuous monitoring of blood flow dynamics in the common carotid arteries in point-of-care settings.
Bladder volume assessments are crucial for managing urinary disorders. Ultrasound imaging (US) is a preferred noninvasive, cost-effective imaging modality for bladder observation and volume measurements. However, the high operator dependency of US is a major challenge due to the difficulty in evaluating ultrasound images without professional expertise. To address this issue, image-based automatic bladder volume estimation methods have been introduced, but most conventional methods require high-complexity computing resources that are not available in point-of-care (POC) settings. Therefore, in this study, a deep learning-based bladder volume measurement system was developed for POC settings using a lightweight convolutional neural network (CNN)-based segmentation model, which was optimized on a low-resource system-on-chip (SoC) to detect and segment the bladder region in ultrasound images in real time. The proposed model achieved high accuracy and robustness and can be executed on the low-resource SoC at 7.93 frames per second, which is 13.44 times faster than the frame rate of a conventional network with negligible accuracy drawbacks (0.004 of the Dice coefficient). The feasibility of the developed lightweight deep learning network was demonstrated using tissue-mimicking phantoms.