Sergio Silvestri

Prof. Sergio Silvestri

Università Campus Bio-Medico, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Andrea NicolòAndrea Nicolò
Andrea Nicolò
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Massimo SacchettiMassimo Sacchetti
Massimo Sacchetti
SSSergio Silvestri
Sergio Silvestri
Emiliano SchenaEmiliano Schena
Emiliano Schena
There is an ever-growing demand for measuring respiratory variables during a variety of applications, including monitoring in clinical and occupational settings, and during sporting activities and exercise. Special attention is devoted to the monitoring of respiratory rate because it is a vital sign, which responds to a variety of stressors. There are different methods for measuring respiratory rate, which can be classed as contact-based or contactless. The present paper provides an overview of the currently available contact-based methods for measuring respiratory rate. For these methods, the sensing element (or part of the instrument containing it) is attached to the subject’s body. Methods based upon the recording of respiratory airflow, sounds, air temperature, air humidity, air components, chest wall movements, and modulation of the cardiac activity are presented. Working principles, metrological characteristics, and applications in the respiratory monitoring field are presented to explore potential development and applicability for each method.

13 September 2013 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Emiliano SchenaEmiliano Schena
Emiliano Schena
SSSergio Silvestri
Sergio Silvestri
Laser-induced thermotherapy (LITT) is a hyperthermic procedure recently employed to treat cancer in several organs. The amount of coagulated tissue depends on the temperature distribution around the applicator, which plays a crucial role for an optimal outcome: the removal of the whole neoplastic tissue, whilst preventing damage to the surrounding healthy tissue. Although feedback concerning tissue temperature could be useful to drive the physician in the adjustment of laser settings and treatment duration, LITT is usually performed without real-time monitoring of tissue temperature. During recent decades, many thermometric techniques have been developed to be used during thermal therapies. This paper provides an overview of techniques and sensors employed for temperature measurement during tissue hyperthermia, focusing on LITT, and an investigation of their performances in this application. The paper focuses on the most promising and widespread temperature monitoring techniques, splitting them into two groups: the former includes invasive techniques based on the use of thermocouples and fibre-optic sensors; the second analyses non-invasive methods, i.e. magnetic resonance imaging-, computerised tomography- and ultrasound-based thermometry. Background information on measuring principle, medical applications, advantages and weaknesses of each method are provided and discussed.

1 October 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
Emiliano SchenaEmiliano Schena
Emiliano Schena
Michele Arturo CaponeroMichele Arturo Caponero
Michele Arturo Caponero
FMF. M. Di Matteo
F. M. Di Matteo
MMM. Martino
M. Martino
SSSergio Silvestri
Sergio Silvestri
Laser-induced interstitial thermotherapy (LITT) has been recently applied to pancreas in animal models for ablation purpose. Assessment of thermal effects due to the laser-pancreatic tissue interaction is a critical factor in validating the procedure feasibility and safety. A mathematical model based on bioheat equation and its experimental assessment was developed. The LITT procedure was performed on 40 ex vivo porcine pancreases, with an Nd:YAG (1064 nm) energy of 1000 J and power from 1.5 up to 10 W conveyed by a quartz optical fiber with 300 μm diameter. Six fiber Bragg grating sensors have been utilized to measure temperature distribution as a function of time at fixed distances from the applicator tip within pancreas undergoing LITT. Simulations and experiments show temperature variations ΔT steeply decreasing with distance from the applicator at higher power values: at 6 W, ΔT >; 40°C at 5 mm and ΔT ≅ 5°C at 10 mm. ΔT nonlinearly increases with power close to the applicator. Ablated and coagulated tissue volumes have also been measured and experimental results agree with theoretical ones. Despite the absence of data in the current literature on pancreas optical parameters, the model allowed a quite good prediction of thermal effects. The prediction of LITT effects on pancreas is necessary to assess laser dosimetry.

22 April 2004 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Domenico FormicaDomenico Formica
Domenico Formica
SSSergio Silvestri
Sergio Silvestri
The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to allow the integration of the specific literature on the bio-effects produced by magnetic resonance systems with the vast literature concerning the bio-effects produced by electromagnetic fields. This work gives an overview of the findings about the safety concerns of exposure to static magnetic fields, radio-frequency fields, and time varying magnetic field gradients, focusing primarily on the physics of the interactions between these electromagnetic fields and biological matter. The scientific literature is summarized, integrated, and critically analyzed with the help of authoritative reviews by recognized experts, international safety guidelines are also cited.

25 June 2014 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
FFF. Fani
F. Fani
Emiliano SchenaEmiliano Schena
Emiliano Schena
Paola SaccomandiPaola Saccomandi
Paola Saccomandi
SSSergio Silvestri
Sergio Silvestri
The dependence of computed tomography (CT) values on temperature has been pointed out by several authors since the late 1970s. They emphasised the importance of this phenomenon on the calibration process with water equivalent phantoms of the CT scanners. Few years later the potential of CT thermometry for non-invasive temperature mapping during thermal procedures was investigated. The interest on the employment of this technique during thermal treatments has been recently renewed with the improvement of modern CT scanner performances and with the increased popularity of minimally invasive thermal techniques for cancer treatment. A good thermometry allows avoiding unintended damage of the healthy tissues during the procedure by providing a detailed tissue temperature distribution; therefore, it is recommended in order to achieve good effectiveness of the thermal treatment. Researchers have been working on this issue for more than four decades and different non-invasive solutions have been proposed, i.e., microwave thermal imaging, infrared (IR)-, ultrasound-, magnetic-resonance (MR)-, and CT-based thermometry. This review aims to summarise the essential physics and the currently available data on CT-based thermometry and to elucidate the potential use of this technique during thermal procedures. Background information on measuring principle, an investigation of the performances achieved by this technique and the thermal sensitivity of the CT-number of different organs are provided and discussed.

2 October 2020 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
APAlessandra Piccoli
Alessandra Piccoli
FCFrancesca Cannata
Francesca Cannata
RSRocky Strollo
Rocky Strollo
CPClaudio Pedone
Claudio Pedone
GLGiulia Leanza
Giulia Leanza
NNNicola Napoli
Nicola Napoli
Increased circulating sclerostin and accumulation of advanced glycation end‐products (AGEs) are two potential mechanisms underlying low bone turnover and increased fracture risk in type 2 diabetes (T2D). Whether the expression of the sclerostin‐encoding SOST gene is altered in T2D, and whether it is associated with AGEs accumulation or regulation of other bone formation‐related genes is unknown. We hypothesized that AGEs accumulate and SOST gene expression is upregulated in bones from subjects with T2D, leading to downregulation of bone forming genes (RUNX2 and osteocalcin ) and impaired bone microarchitecture and strength. We obtained bone tissue from femoral heads of 19 T2D postmenopausal women (mean HbA1c 6.5%) and 73 age‐ and BMI‐comparable non‐diabetic women undergoing hip replacement surgery. Despite similar bone mineral density (BMD) and biomechanical properties, we found a significantly higher SOST (p=0.006) and a parallel lower RUNX2 (p=0.025) expression in T2D compared with non‐diabetic subjects. Osteocalcin gene expression did not differ between T2D and non‐diabetic subjects, as well as circulating osteocalcin and sclerostin levels. We found a 1.5‐fold increase in total bone AGEs content in T2D compared with non‐diabetic women (364.8±78.2 vs. 209.9±34.4 μg quinine/g collagen, respectively; p<0.001). AGEs bone content correlated with worse bone microarchitecture, including lower volumetric BMD (r=‐0.633; p=0.02), BV/TV (r=‐0.59; p=0.033) and increased trabecular separation/spacing (r= 0.624; p=0.023). In conclusion, our data show that even in patients with good glycemic control, T2D affects the expression of genes controlling bone formation (SOST and RUNX2). We also found that accumulation of AGEs is associated with impaired bone microarchitecture. We provide novel insights that may help understand the mechanisms underlying bone fragility in T2D.