SUMMARY: Intracranial aneurysms are a common pathologic condition with a potential severe complication: rupture. Effective treatment options exist, neurosurgical clipping and endovascular techniques, but guidelines for treatment are unclear and focus mainly on patient age, aneurysm size, and localization. New criteria to define the risk of rupture are needed to refine these guidelines. One potential candidate is aneurysm wall motion, known to be associated with rupture but difficult to detect and quantify. We review what is known about the association between aneurysm wall motion and rupture, which structural changes may explain wall motion patterns, and available imaging techniques able to analyze wall motion.
14 July 2015 in Journal of NeuroInterventional Surgery
Background: Particular intra-aneurysmal blood flow conditions, created naturally by the growth of an aneurysm or induced artificially by implantation of a flow diverter stent (FDS), can potentiate intra-aneurysmal thrombosis. The aim of this study was to identify hemodynamic indicators, relevant to this process, which could be used as a prediction of the success of a preventive endovascular treatment.Method: A cross sectional study on 21 patients was carried out to investigate the possible association between intra-aneurysmal spontaneous thrombus volume and the dome to neck aspect ratio (AR) of the aneurysm. The mechanistic link between these two parameters was further investigated through a Fourier analysis of the intra-aneurysmal shear rate (SR) obtained by computational fluid dynamics (CFD). This analysis was first applied to 10 additional patients (4 with and 6 without spontaneous thrombosis) and later to 3 patients whose intracranial aneurysms only thrombosed after FDS implantation.Results: The cross sectional study revealed an association between intra-aneurysmal spontaneous thrombus volume and the AR of the aneurysm (R2=0.67, p<0.001). Fourier analysis revealed that in cases where thrombosis occurred, the SR harmonics 0, 1, and 2 were always less than 25/s, 10/s, and 5/s, respectively, and always greater than these values where spontaneous thrombosis was not observed.Conclusions: Our study suggests the existence of an SR threshold below which thrombosis will occur. Therefore, by analyzing the SR on patient specific data with CFD techniques, it may be potentially possible to predict whether or the intra-aneurysmal flow conditions, after FDS implantation, will become prothrombotic.
1 December 2007 in International Journal of Modern Physics C
Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.