Nelly Bonifaci

Prof. Nelly Bonifaci

Université Grenoble Alpes, Grenoble, Auvergne-Rhône-Alpes, France

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2008 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
SIS Ingebrigtsen
S Ingebrigtsen
NBNelly Bonifaci
Nelly Bonifaci
ADA Denat
A Denat
OLO Lesaint
O Lesaint

27 February 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
RCRaphael Chassagnoux
Raphael Chassagnoux
OLOlivier Lesaint
Olivier Lesaint
NBNelly Bonifaci
Nelly Bonifaci
OGOlivier Gallot-Lavallee
Olivier Gallot-Lavallee
SFSebastien Flury
Sebastien Flury
AGAlain Girodet
Alain Girodet

14 May 2020 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
TLTing Liu
Ting Liu
ITIgor Timoshkin
Igor Timoshkin
SMScott J. MacGregor
Scott J. MacGregor
MWMark P. Wilson
Mark P. Wilson
MGMartin John Given
Martin John Given
RHRachelle Hanna
Rachelle Hanna
The dielectric performance of gases in insulation systems used in high voltage power and pulsed power applications is a subject of intensive theoretical and experimental investigations. Transient breakdown processes in gases stressed with short, high-field impulses, have been studied for many decades. However, there are still significant gaps in the understanding of the main breakdown processes and mechanisms associated with fast transient breakdown processes in gases. This knowledge is important for the optimization of gaseous insulating systems and for the coordination of gaseous insulation in power and pulsed power apparatuses. This information is also required for the development of gas-filled components such as circuit breakers and plasma closing switches. This article is aimed at the analysis of the field-time breakdown characteristics of air, N₂, CO₂, and SF₆, using kinetic and drift-diffusion approaches. The kinetic approach is based upon the avalanche-to-streamer transition criterion, while the fluid drift-diffusion model requires self-consistent numerical solution of the continuity equations for charged species, and the Poisson equation for the electric field. The time to breakdown as a function of the applied field was obtained for all investigated gases. The obtained analytical results agree well with the experimental data reported in the literature, which suggests that both approaches can be used for insulation coordination, and for the development of gas-insulated power and pulsed power systems and components.

9 May 2022 in J
Verified
Journal Article
Open access
PDF file
FBFrancis Boakye-Mensah
Francis Boakye-Mensah
NBNelly Bonifaci
Nelly Bonifaci
RHRachelle Hanna
Rachelle Hanna
INInnocent Niyonzima
Innocent Niyonzima
ITIgor Timoshkin
Igor Timoshkin
The use of SF6 in electrical insulation and fast-switching applications cannot be overemphasized. This is due to its excellent dielectric properties and high breakdown voltage, which are especially important for practical applications such as gas-insulated switchgears and pulsed power switches where pressurized SF6 is used. Breakdown in the gas occurs via streamer–leader transition; however, this transition is difficult to quantify numerically at atmospheric pressure because of the electronegativity of the gas. In the present work, streamer discharges in SF6 gas at pressures of 10 and 100 kPa were studied using a plasma fluid model implementation. Analysis of the electric field in the streamer body, streamer velocity, diameter, and the effect of the high electronegativity of the gas on streamer parameters are presented for positive polarity in a point-to-plane geometry. The streamers in SF6 for non-uniform background fields are compared to those in air, which have already been studied extensively in the literature.

3 March 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
RCRaphaël Chassagnoux
Raphaël Chassagnoux
OLOlivier Lesaint
Olivier Lesaint
NBNelly Bonifaci
Nelly Bonifaci
OGOlivier Gallot-Lavallée
Olivier Gallot-Lavallée
CCChristophe Creusot
Christophe Creusot
AGAlain Girodet
Alain Girodet
Pre-breakdown and breakdown phenomena are investigated in liquid Nitrogen (LN 2 ) with a tape-plane electrode geometry. Different voltage waveforms are used: lightning and switching standard impulses, step impulse, and DC ramp. The influence of temperature is also investigated, by sub-cooling LN 2 down to 65 K. Breakdown voltage depends on polarity, gap distance, temperature, and HV waveform: the longer waveform, the lower breakdown voltage. Positive pre-breakdown streamers are about 3 decades faster than negative ones. With short duration lightning impulses, the propagation of slow negative streamers is quenched, resulting in higher breakdown voltage. In boiling conditions, slow negative streamers may propagate for long durations. Sub-cooling LN 2 induces a slight increase of streamer initiation voltage, and impedes the propagation of slow streamers due to condensation.

3 March 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
RCR. Chassagnoux
R. Chassagnoux
OLOlivier Lesaint
Olivier Lesaint
NBNelly Bonifaci
Nelly Bonifaci
OGOlivier Gallot-Lavallée
Olivier Gallot-Lavallée
CCChristophe Creusot
Christophe Creusot
AGAlain Girodet
Alain Girodet
Resistive superconducting fault current limiters constitute a promising solution for high voltage networks. During the resistive current limitation, transient overvoltages and heat dissipation occur on superconducting tapes, inducing fast boiling of surrounding liquid nitrogen (LN 2 ). An experimental system reproducing the fast transient heating of a tape electrode, synchronized with a high voltage impulse is described. Breakdown voltages measurements in both polarities are carried out versus synchronization delay, pressure (0.10 to 0.40 MPa), temperature (77 K and 65 K). Breakdown voltages show complex variations with these parameters. More insight is obtained from the recording of pre-breakdown phenomena (streamer). The size of vapor bubbles has a large and counter-intuitive influence on streamer initiation: the smaller bubbles, the lower inception voltage. Subcooling LN 2 (by decreasing temperature and/or increasing pressure) sometimes has a beneficial influence (quenching of negative streamer propagation), but deleterious effects can be as well observed in other circumstances (by favouring positive streamer initiation).