Riad Akhundov

Dr. Riad Akhundov

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RARiad Akhundov
Riad Akhundov
DSDavid J. Saxby
David J. Saxby
LDLaura E. Diamond
Laura E. Diamond
SESuzi Edwards
Suzi Edwards
PCPhil Clausen
Phil Clausen
SSSuzanne J. Snodgrass
Suzanne J. Snodgrass
The majority of musculoskeletal modelling studies investigating healthy populations use generic models linearly scaled to roughly match an individual’s anthropometry. Generic models disregard the considerable variation in musculoskeletal geometry and tissue properties between individuals. This study investigated the physiological implications of personalizing musculoskeletal model geometry (body segment mass, inertia, joint center, and maximum isometric muscle force). Nine healthy athletes performed ten repetitions of 15 meter sprints at 75–95% of their maximum sprinting speed and ten repetitions of unanticipated sidestep cut trials with a 4.5–5.5 m/s approach running speed. Structural magnetic resonance imaging was collected on the lower extremities, from which subject-specific musculoskeletal models were developed. A one-dimensional statistical parametric mapping paired t-test was used to compare generic and subject-specific musculoskeletal models for: lower-limb kinematics, kinetics, torque matching, as well as hamstrings, adductors, and quadriceps muscle activations and fiber dynamics. Percentage change of geometric parameters between generic and subject-specific models were determined. Compared to generic models, subject-specific models showed significantly lower ankle dorsi/plantar flexion angle during sprinting and several significantly different net joint moments during sprint and cut tasks. Additionally, subject-specific models demonstrated better torque matching, more physiologically plausible fiber lengths, higher fiber velocities, lower muscle forces, and lower simulated activations in a subset of investigated muscles and motor tasks. Furthermore, subject-specific models identified between-limb differences that were not identified with generic models. Use of subject-specific modeling, even in healthy populations, may result in more physiologically plausible muscle fiber mechanics. Implementing subject-specific models may be especially beneficial when investigating populations with substantial geometric between-limb differences, or unilateral musculoskeletal pathologies, as these are not captured by a generic model.

1 January 2019 in Journal of Experimental Biology
Verified
Journal Article
Closed access
PDF file
RARiad Akhundov
Riad Akhundov
DSDavid John Saxby
David John Saxby
SESuzi Edwards
Suzi Edwards
SSSuzanne Snodgrass
Suzanne Snodgrass
PCPhilip Clausen
Philip Clausen
LDLaura E. Diamond
Laura E. Diamond
Determining the signal quality of surface electromyography (sEMG) recordings is time consuming and requires the judgment of trained observers. An automated procedure to evaluate sEMG quality would streamline data processing and reduce time demands. This paper compares the performance of two supervised and three unsupervised artificial neural networks (ANNs) in evaluation of sEMG quality. Manually classified sEMG recordings from various lower-limb muscles during motor tasks were used to train (n=28000), test performance (n=12000), and evaluate accuracy (n=47000) of the five ANNs in classifying signals into four categories. Unsupervised ANNs demonstrated a 30-40% increase in classification accuracy (>98%) compared to supervised ANNs. AlexNet demonstrated the highest accuracy (99.55%) with negligible false classifications. Results indicate that sEMG quality evaluation can be automated via an ANN without compromising human-like classification accuracy. This classifier will be publicly available and will be a valuable tool for researchers and clinicians using electromyography.

28 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
RLroger lee
roger lee
RARiad Akhundov
Riad Akhundov
CJCarole James
Carole James
SESuzi Edwards
Suzi Edwards
SSSuzanne J. Snodgrass
Suzanne J. Snodgrass
Inertial measurement units (IMUs) may provide an objective method for measuring posture during computer use, but research is needed to validate IMUs’ accuracy. We examine the concurrent validity of two different IMU systems in measuring three-dimensional (3D) upper body posture relative to a motion capture system (Mocap) as a potential device to assess postures outside a laboratory environment. We used 3D Mocap and two IMU systems (Wi-Fi and Bluetooth) to capture the upper body posture of twenty-six individuals during three physical computer working conditions (monitor correct, monitor raised, and laptop). Coefficient of determination (R2) and root-mean-square error (RMSE) compared IMUs to Mocap. Head/neck segment [HN], upper trunk segment [UTS], and joint angle [HN-UTS] were the primary variables. Wi-Fi IMUs demonstrated high validity for HN and UTS (sagittal plane) and HN-UTS (frontal plane) for all conditions, and for HN rotation movements (both for the monitor correct and monitor raised conditions), others moderate to poor. Bluetooth IMUs for HN, and UTS (sagittal plane) for the monitor correct, laptop, and monitor raised conditions were moderate. Frontal plane movements except UTS (monitor correct and laptop) and all rotation had poor validity. Both IMU systems were affected by gyroscopic drift with sporadic data loss in Bluetooth IMUs. Wi-Fi IMUs had more acceptable accuracy when measuring upper body posture during computer use compared to Mocap, except for trunk rotations. Variation in IMU systems’ performance suggests validation in the task-specific movement(s) is essential.

26 July 2022 in Life
Verified
Journal Article
Open access
PDF file
RARiad Akhundov
Riad Akhundov
Adam Leigh BryantAdam Leigh Bryant
Adam Leigh Bryant
TSTim Sayer
Tim Sayer
KPKade Paterson
Kade Paterson
DSDavid John Saxby
David John Saxby
ANAzadeh Nasseri
Azadeh Nasseri
Rates of anterior cruciate ligament (ACL) rupture in young people have increased markedly over the past two decades, with females experiencing greater growth in their risk compared to males. In this study, we determined the effects of low- and high-support athletic footwear on ACL loads during a standardized drop–land–lateral jump in 23 late-/post-pubertal females. Each participant performed the task unshod, wearing low- (Zaraca, ASICS) or high- (Kayano, ASICS) support shoes (in random order), and three-dimensional body motions, ground-reaction forces, and surface electromyograms were synchronously acquired. These data were then used in a validated computational model of ACL loading. One-dimensional statistical parametric mapping paired t-tests were used to compare ACL loads between footwear conditions during the stance phase of the task. Participants generated lower ACL forces during push-off when shod (Kayano: 624 N at 71–84% of stance; Zaraca: 616 N at 68–86% of stance) compared to barefoot (770 N and 740 N, respectively). No significant differences in ACL force were observed between the task performed wearing low- compared to high-support shoes. Compared to barefoot, both shoe types significantly lowered push-off phase peak ACL forces, potentially lowering risk of ACL injury during performance of similar tasks in sport and recreation.

18 October 2022 in Sports Biomechanics
Verified
Journal Article
Closed access
RARiad Akhundov
Riad Akhundov
DSDavid J Saxby
David J Saxby
LDLaura E Diamond
Laura E Diamond
Suzanne  SnodgrassSuzanne Snodgrass
Suzanne Snodgrass
PCPhil Clausen
Phil Clausen
SESuzi Edwards
Suzi Edwards
Muscle tendon unit fibre mechanics of hamstring and adductor strain injuries are not well studied, with factors such as fatigue promoted as risk factors in the absence of mechanistic evidence. In this study, musculoskeletal modelling was used to estimate fibre mechanics of four hamstring (biceps femoris long head, biceps femoris short head, semimembranosus and semitendinosus) and four adductor (adductor brevis, adductor longus, adductor magnus and gracilis) muscles during an anticipated cut task. The cut task was performed by 10 healthy elite male U20 basketball players both before and immediately after they played in one (of four) competitive basketball game. Biceps femoris long head produced significantly lower (p = 0.032) submaximal force post-game in the latter part of swing (30.7% to 35.0% of stride), though its peak force occurred later (37%) and remained unchanged. Semimembranosus produced significantly lower (p = 0.006) force post-game (32.9% to 44.9% of stride), which encompassed the instance of peak force (39%). Neither fibre velocity nor fibre length of the investigated muscles were significantly affected by game-play. These finding suggest that if fatigue is a factor in hamstring and adductor muscle strain injuries and is brought about by game-play, it is unlikely through the fibre mechanisms investigated in this study.

17 March 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
ANAzadeh Nasseri
Azadeh Nasseri
RARiad Akhundov
Riad Akhundov
Adam Leigh BryantAdam Leigh Bryant
Adam Leigh Bryant
DLDavid Lloyd
David Lloyd
DSDavid John Saxby
David John Saxby
Neuromusculoskeletal models often require three-dimensional (3D) body motions, ground reaction forces (GRF), and electromyography (EMG) as input data. Acquiring these data in real-world settings is challenging, with barriers such as the cost of instruments, setup time, and operator skills to correctly acquire and interpret data. This study investigated the consequences of limiting EMG and GRF data on modelled anterior cruciate ligament (ACL) forces during a drop–land–jump task in late-/post-pubertal females. We compared ACL forces generated by a reference model (i.e., EMG-informed neural mode combined with 3D GRF) to those generated by an EMG-informed with only vertical GRF, static optimisation with 3D GRF, and static optimisation with only vertical GRF. Results indicated ACL force magnitude during landing (when ACL injury typically occurs) was significantly overestimated if only vertical GRF were used for either EMG-informed or static optimisation neural modes. If 3D GRF were used in combination with static optimisation, ACL force was marginally overestimated compared to the reference model. None of the alternative models maintained rank order of ACL loading magnitudes generated by the reference model. Finally, we observed substantial variability across the study sample in response to limiting EMG and GRF data, indicating need for methods incorporating subject-specific measures of muscle activation patterns and external loading when modelling ACL loading during dynamic motor tasks.