Chen Jiahao

Mr. Chen Jiahao


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SYShuo Yang
Shuo Yang
CJChen Jiahao
Chen Jiahao
ALAn Li
An Li
Ping LiPing Li
Ping Li
Shulan XuShulan Xu
Shulan Xu
Robotic systems have emerged in dental implant surgery due to their accuracy. Autonomous robotic surgery may offer unprecedented advantages over conventional alternatives. This clinical protocol was used to show the feasibility of autonomous robotic surgery for immediately loaded implant-supported full-arch prostheses in the maxilla. This case report demonstrated the surgical protocol and outcomes in detail, highlighting the pros and cons of the autonomous robotic system. Within the limitations of this study, autonomous robotic surgery could be a feasible alternative to computer-assisted guided implant surgery.

3 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
CJChen Jiahao
Chen Jiahao
JDJingtao Dai
Jingtao Dai
JQJunyu Qian
Junyu Qian
WLweirong li
weirong li
RLRonghui Li
Ronghui Li
Shulan XuShulan Xu
Shulan Xu
High-purity magnesium (Mg) is a promising biodegradable metal for oral and maxillofacial implants. Appropriate surface roughness plays a critical role in the degradation behavior and the related cellular processes of biodegradable Mg-based metals. Nevertheless, the most optimized surface roughness has been questionable, especially for Mg-based oral and maxillofacial implants. Three representative scales of surface roughness were investigated in this study, including smooth (Sa < 0.5 µm), moderately rough (Sa between 1.0–2.0 µm), and rough (Sa > 2.0 µm). The results indicated that the degradation rate of the Mg specimen in the cell culture medium was significantly accelerated with increased surface roughness. Furthermore, an extract test revealed that Mg with different roughness did not induce an evident cytotoxic effect. Nonetheless, the smooth Mg surface had an adversely affected cell attachment. Therefore, the high-purity Mg with a moderately rough surface exhibited the most optimized balance between biodegradability and overall cytocompatibility.

20 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
PZPeijun Zhu
Peijun Zhu
CJChen Jiahao
Chen Jiahao
Ping LiPing Li
Ping Li
Shulan XuShulan Xu
Shulan Xu
Zinc (Zn) and its alloys have been regarded as promising biodegradable metals. The standardized cytotoxicity evaluation is a mandatory step to screen the biocompatibility of novel Zn and its alloys. Nevertheless, the suitability of the tetrazolium-based assay in the direct contact test for some metallic biomaterials (i.e., magnesium and manganese) is questionable. In this study, our results demonstrate an obvious inconsistency between qualitative observation via fluorescence staining and quantitative assessment using water-soluble tetrazolium salt (CCK-8). Subsequent experiments revealed that Zn and pre-treated Zn can directly convert tetrazolium salts to formazan, falsifying the cytotoxicity results. Therefore, we conclude that the CCK-8 assay is not suitable for evaluating the cytotoxicity of biodegradable Zn-based metals in the direct contact test.