Ping Li

Prof. Dr. Ping Li

University Hospital Tübingen
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
XHXingting Han
Xingting Han
DYDong Yang
Dong Yang
CYChuncheng Yang
Chuncheng Yang
SSSebastian Spintzyk
Sebastian Spintzyk
LSLutz Scheideler
Lutz Scheideler
FRFrank Rupp
Frank Rupp
Fused deposition modeling (FDM) is a rapidly growing three-dimensional (3D) printing technology and has great potential in medicine. Polyether-ether-ketone (PEEK) is a biocompatible high-performance polymer, which is suitable to be used as an orthopedic/dental implant material. However, the mechanical properties and biocompatibility of FDM-printed PEEK and its composites are still not clear. In this study, FDM-printed pure PEEK and carbon fiber reinforced PEEK (CFR-PEEK) composite were successfully fabricated by FDM and characterized by mechanical tests. Moreover, the sample surfaces were modified with polishing and sandblasting methods to analyze the influence of surface roughness and topography on general biocompatibility (cytotoxicity) and cell adhesion. The results indicated that the printed CFR-PEEK samples had significantly higher general mechanical strengths than the printed pure PEEK (even though there was no statistical difference in compressive strength). Both PEEK and CFR-PEEK materials showed good biocompatibility with and without surface modification. Cell densities on the “as-printed” PEEK and the CFR-PEEK sample surfaces were significantly higher than on the corresponding polished and sandblasted samples. Therefore, the FDM-printed CFR-PEEK composite with proper mechanical strengths has potential as a biomaterial for bone grafting and tissue engineering applications.

Verified
Journal Article
Open access
PDF file
Ping LiPing Li
Ping Li
CSChristine Schille
Christine Schille
ESErnst Schweizer
Ernst Schweizer
FRFrank Rupp
Frank Rupp
AHAlexander Heiss
Alexander Heiss
LSLutz Scheideler
Lutz Scheideler
Zn-based biodegradable metallic materials have been regarded as new potential biomaterials for use as biodegradable implants, mainly because of the ideal degradation rate compared with those of Mg-based alloys and Fe-based alloys. In this study, we developed and investigated a novel Zn-4 wt % Ag alloy as a potential biodegradable metal. A thermomechanical treatment was applied to refine the microstructure and, consequently, to improve the mechanical properties, compared to pure Zn. The yield strength (YS), ultimate tensile strength (UTS) and elongation of the Zn-4Ag alloy are 157 MPa, 261 MPa, and 37%, respectively. The corrosion rate of Zn-4Ag calculated from released Zn ions in DMEM extracts is approximately 10.75 ± 0.16 μg cm–2 day–1, which is higher than that of pure Zn. In vitro cytotoxicity tests showed that the Zn-4Ag alloy exhibits acceptable toxicity to L929 and Saos-2 cells, and could effectively inhibit initial bacteria adhesion. This study shows that the Zn-4Ag exhibits excellent mechanical properties, predictable degradation behavior, acceptable biocompatibility, and effective antibacterial properties, which make it a candidate biodegradable material.

1 October 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
Ping LiPing Li
Ping Li
WZWentai Zhang
Wentai Zhang
JDJingtao Dai
Jingtao Dai
AXAlexander Basileos Xepapadeas
Alexander Basileos Xepapadeas
ESErnst Schweizer
Ernst Schweizer
JGJürgen Geis-Gerstorfer
Jürgen Geis-Gerstorfer

Verified
Journal Article
Open access
PDF file
AUAlexey Unkovskiy
Alexey Unkovskiy
FSFranziska Schmidt
Franziska Schmidt
FBFlorian Beuer
Florian Beuer
Ping LiPing Li
Ping Li
SSSebastian Spintzyk
Sebastian Spintzyk
PFPablo Kraemer Fernandez
Pablo Kraemer Fernandez
The topical literature lacks any comparison between stereolithography (SLA) and direct light processing (DLP) printing methods with regard to the accuracy of complete denture base fabrication, thereby utilizing materials certified for this purpose. In order to investigate this aspect, 15 denture bases were printed with SLA and DLP methods using three build angles: 0°, 45° and 90°. The dentures were digitalized using a laboratory scanner (D2000, 3Shape) and analyzed in analyzing software (Geomagic Control X, 3D systems). Differences between 3D datasets were measured using the root mean square (RMS) value for trueness and precision and mean and maximum deviations were obtained for each denture base. The data were statistically analyzed using two-way ANOVA and Tukey’s multiple comparison test. A heat map was generated to display the locations of the deviations within the intaglio surface. The overall tendency indicated that SLA denture bases had significantly higher trueness for most build angles compared to DLP (p < 0.001). The 90° build angle may provide the best trueness for both SLA and DLP. With regard to precision, statistically significant differences were found in the build angles only. Higher precision was revealed in the DLP angle of 0° in comparison to the 45° and 90° angles.

11 February 2023 in Journal of Dentistry
Verified
Journal Article
Closed access
SYShuo Yang
Shuo Yang
JCJiahao Chen
Jiahao Chen
ALAn Li
An Li
KDKe Deng
Ke Deng
Ping LiPing Li
Ping Li
Shulan XuShulan Xu
Shulan Xu

1 May 2021 in Dental Materials
Verified
Journal Article
Closed access
YXYichen Xu
Yichen Xu
AXAlexander B. Xepapadeas
Alexander B. Xepapadeas
BKBernd Koos
Bernd Koos
JGJürgen Geis-Gerstorfer
Jürgen Geis-Gerstorfer
Ping LiPing Li
Ping Li
SSSebastian Spintzyk
Sebastian Spintzyk