Carlos Albors Lucas

Mr. Carlos Albors Lucas

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2024 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
CLCarlos Albors Lucas
Carlos Albors Lucas
JMJordi Mill
Jordi Mill
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
XIXavier Iriart
Xavier Iriart
HCHubert Cochet
Hubert Cochet
OCOscar Camara
Oscar Camara
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.

24 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CLCarlos Albors Lucas
Carlos Albors Lucas
ÈLÈric Lluch
Èric Lluch
JGJuan Francisco Gomez
Juan Francisco Gomez
NCNicolas Cedilnik
Nicolas Cedilnik
Konstantinos A MountrisKonstantinos A Mountris
Konstantinos A Mountris
OCOscar Camara
Oscar Camara
Computational models of cardiac electrophysiology are promising tools for reducing the rates of non-response patients suitable for cardiac resynchronization therapy (CRT) by optimizing electrode placement. The majority of computational models in the literature are mesh-based, primarily using the finite element method (FEM). The generation of patient-specific cardiac meshes has traditionally been a tedious task requiring manual intervention and hindering the modeling of a large number of cases. Meshless models can be a valid alternative due to their mesh quality independence. The organization of challenges such as the CRT-EPiggy19, providing unique experimental data as open access, enables benchmarking analysis of different cardiac computational modeling solutions with quantitative metrics. We present a benchmark analysis of a meshless-based method with finite-element methods for the prediction of cardiac electrical patterns in CRT, based on a subset of the CRT-EPiggy19 dataset. A data assimilation strategy was designed to personalize the most relevant parameters of the electrophysiological simulations and identify the optimal CRT lead configuration. The simulation results obtained with the meshless model were equivalent to FEM, with the most relevant aspect for accurate CRT predictions being the parameter personalization strategy (e.g., regional conduction velocity distribution, including the Purkinje system and CRT lead distribution).

1 January 2022
Verified
Book Chapter
Closed access
PDF file
CLCarlos Albors Lucas
Carlos Albors Lucas
JMJordi Mill
Jordi Mill
HKHenrik A. Kjeldsberg
Henrik A. Kjeldsberg
DMDavid Viladés Medel
David Viladés Medel
AOAndy L. Olivares
Andy L. Olivares
OCOscar Camara
Oscar Camara

15 January 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
CLCarlos Albors Lucas
Carlos Albors Lucas
JMJordi Mill
Jordi Mill
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
Xavier IriartXavier Iriart
Xavier Iriart
HCHubert Cochet
Hubert Cochet
OCOscar Camara
Oscar Camara
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT. Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.

16 June 2023
Verified
Book Chapter
Closed access
PDF file
CLCarlos Albors Lucas
Carlos Albors Lucas
AOAndy L. Olivares
Andy L. Olivares
XIXavier Iriart
Xavier Iriart
HCHubert Cochet
Hubert Cochet
JMJordi Mill
Jordi Mill
OCOscar Camara
Oscar Camara

29 May 2025
Verified
Book Chapter
Closed access
PDF file
EGEmanuele Gasparotti
Emanuele Gasparotti
EVEmanuele Vignali
Emanuele Vignali
RMRachele Marangoni
Rachele Marangoni
JMJordi Mill
Jordi Mill
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
Simona CeliSimona Celi
Simona Celi