Andy Luis Olivares Miyares

Prof. Dr. Andy Luis Olivares Miyares

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2018 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
GGGuadalupe García‐Isla
Guadalupe García‐Isla
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
EGEtel silva garcia
Etel silva garcia
MNMarta Nuñez‐Garcia
Marta Nuñez‐Garcia
CBConstantine Butakoff
Constantine Butakoff
OCOscar Camara
Oscar Camara

18 September 2021 in Mathematics
Verified
Journal Article
Open access
PDF file
JMJordi Mill
Jordi Mill
VAVictor Agudelo
Victor Agudelo
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
MPMaria Isabel Pons
Maria Isabel Pons
EGEtel silva garcia
Etel silva garcia
OCOscar Camara
Oscar Camara
Atrial fibrillation (AF) is nowadays the most common human arrhythmia and it is considered a marker of an increased risk of embolic stroke. It is known that 99% of AF-related thrombi are generated in the left atrial appendage (LAA), an anatomical structure located within the left atrium (LA). Left atrial appendage occlusion (LAAO) has become a good alternative for nonvalvular AF patients with contraindications to anticoagulants. However, there is a non-negligible number of device-related thrombus (DRT) events, created next to the device surface. In silico fluid simulations can be a powerful tool to better understand the relation between LA anatomy, haemodynamics, and the process of thrombus formation. Despite the increasing literature in LA fluid modelling, a consensus has not been reached yet in the community on the optimal modelling choices and boundary conditions for generating realistic simulations. In this line, we have performed a sensitivity analysis of several boundary conditions scenarios, varying inlet/outlet and LA wall movement configurations, using patient-specific imaging data of six LAAO patients (three of them with DRT at follow-up). Mesh and cardiac cycle convergence were also analysed. The boundary conditions scenario that better predicted DRT cases had echocardiography-based velocities at the mitral valve outlet, a generic pressure wave from an AF patient at the pulmonary vein inlets, and a dynamic mesh approach for LA wall deformation, emphasizing the need for patient-specific data for realistic simulations. The obtained promising results need to be further validated with larger cohorts, ideally with ground truth data, but they already offer unique insights on thrombogenic risk in the left atria.

14 March 2022 in Journal of Interventional Cardiology
Verified
Journal Article
Open access
PDF file
MPMaria Isabel Pons
Maria Isabel Pons
JMJordi Mill
Jordi Mill
AFAlvaro Fernandez-Quilez
Alvaro Fernandez-Quilez
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
ESEtelvino Silva
Etelvino Silva
OCOscar Camara
Oscar Camara
Background. Atrial fibrillation (AF) is considered the most common human arrhythmia. In nonvalvular AF, around 99 of thrombi are formed in the left atrial appendage (LAA). Nevertheless, there is not a consensus in the community about the relevant factors to stratify the AF population according to thrombogenic risk. Objective. To demonstrate the need for combining left atrial morphological and haemodynamics indices to improve the thrombogenic risk assessment in nonvalvular AF patients. Methods. A cohort of 71 nonvalvular AF patients was analysed. Statistical analysis, regression models, and random forests were used to analyse the differences between morphological and haemodynamics parameters, extracted from computational simulations built on 3D rotational angiography images, between patients with and without transient ischemic attack (TIA) or cerebrovascular accident (CVA). Results. The analysis showed that models composed of both morphological and haemodynamic factors were better predictors of TIA/CVA compared with models based on either morphological or haemodynamic factors separately. Maximum ostium diameter, length of the centreline, blood flow velocity within the LAA, oscillatory shear index, and time average wall shear stress parameters were found to be key risk factors for TIA/CVA prediction. In addition, TIA/CVA patients presented more flow stagnation within the LAA. Conclusion. Thrombus formation in the LAA is the result of multiple factors. Analyses based only on morphological or haemodynamic parameters are not precise enough to predict such a phenomenon, as demonstrated in our results; a better patient stratification can be obtained by jointly analysing morphological and haemodynamic features.

29 January 2024 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
EKEhsan Khalili
Ehsan Khalili
CDCécile Daversin‐Catty
Cécile Daversin‐Catty
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
JMJordi Mill
Jordi Mill
OCOscar Camara
Oscar Camara
KVKristian Valen‐Sendstad
Kristian Valen‐Sendstad

26 September 2024 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
CLCarlos Albors Lucas
Carlos Albors Lucas
JMJordi Mill
Jordi Mill
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
XIXavier Iriart
Xavier Iriart
HCHubert Cochet
Hubert Cochet
OCOscar Camara
Oscar Camara
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.

16 November 2011 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
LRL. R. Rábago
L. R. Rábago
ICI. Chico
I. Chico
DCD. Collado
D. Collado
AMAndy Luis Olivares Miyares
Andy Luis Olivares Miyares
AOA. Ortega
A. Ortega
JEJ. Vazquez Echarri
J. Vazquez Echarri