Jia Ning

Dr. Jia Ning

School of Electric Power Engineering, Nanjing Institute of Technology
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2017 in Energies
Verified
Journal Article
Open access
PDF file
Jia NingJia Ning
Jia Ning
YTYi Tang
Yi Tang
QCQian Chen
Qian Chen
JWJianming Wang
Jianming Wang
JZJianhua Zhou
Jianhua Zhou
Bingtuan GaoBingtuan Gao
Bingtuan Gao
Demand response (DR) is counted as an effective method when there is a large-capacity power shortage in the power system, which may lead to peak loads or a rapid ramp. This paper proposes a bi-level coordinated optimization strategy by quantitating the DR potential (DRP) of smart appliances to descend the steep ramp and balance the power energy. Based on dynamic characteristics of the smart appliances, the mathematic models of online DRP are presented. In the upper layer, a multi-agent coordinated distribution method is proposed to allocate the demand limit to each agent from the dispatching center considering the online DRP. In the lower layer, an optimal smart appliances-controlling strategy is presented to guarantee the total household power consumption of each agent below its demand limit considering the consumers’ comfort and response times. Simulation results indicate the feasibility of the proposed strategy.

29 August 2019 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
JDJianfeng Dai
Jianfeng Dai
YTYi Tang
Yi Tang
YLYuqian Liu
Yuqian Liu
Jia NingJia Ning
Jia Ning
QWQi Wang
Qi Wang
JZJingbo Zhao
Jingbo Zhao
Increasing energy consumption has caused power systems to operate close to the limit of their capacity. The distributed power flow controller (DPFC), as a new member of distributed flexible AC transmission systems, is introduced to remove this barrier. This paper proposes an optimal DPFC configuration method to enhance system loadability considering economic performance based on mixed integer linear programming. The conflicting behavior of system loadability and DPFC investment is analyzed and optimal solutions are calculated. Thereafter, the fuzzy decision-making method is implemented for determining the most preferred solution. In the most preferred solution obtained, the investment of DPFCs is minimized to find the optimal number, locations and set points. Simulation results on the IEEE-RTS79 system demonstrate that the proposed method is effective and reasonable.

8 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
YTYi Tang
Yi Tang
JDJianfeng Dai
Jianfeng Dai
Jia NingJia Ning
Jia Ning
JDJie Dang
Jie Dang
YLYan Li
Yan Li
XTXinshou Tian
Xinshou Tian
With increasing penetration of wind power into the power system, wind power participation in frequency regulation is regarded as a beneficial strategy to improve the dynamic frequency response characteristics of power systems. The traditional power system frequency response (SFR) model, which only includes synchronous generators, is no longer suitable for power systems with high penetrated wind power. An extended SFR model, based on the reduced-order model of wind turbine generator (WTG) and the traditional SFR model, is presented in this paper. In the extended SFR model, the reduced-order model of WTG with combined frequency control is deduced by employing small signal analysis theory. Afterwards, the stability analysis of a closed-loop control system for the extended SFR model is carried out. Time-domain simulations using a test system are performed to validate the effectiveness of the extended SFR model; this model can provide a simpler, clearer and faster way to analyze the dynamic frequency response characteristic for a high-wind integrated power systems. The impact of additional frequency control parameters and wind speed disturbances on the system dynamic frequency response characteristics are investigated.

9 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
YTYi Tang
Yi Tang
YLYuqian Liu
Yuqian Liu
Jia NingJia Ning
Jia Ning
JZJingbo Zhao
Jingbo Zhao
The inherent variability and randomness of large-scale wind power integration have brought great challenges to power flow control and dispatch. The distributed power flow controller (DPFC) has the higher flexibility and capacity in power flow control in the system with wind generation. This paper proposes a multi-time scale coordinated scheduling model with DPFC to minimize wind power spillage. Configuration of DPFCs is initially determined by stochastic method. Afterward, two sequential procedures containing day-head and real-time scales are applied for determining maximum schedulable wind sources, optimal outputs of generating units and operation setting of DPFCs. The generating plan is obtained initially in day-ahead scheduling stage and modified in real-time scheduling model, while considering the uncertainty of wind power and fast operation of DPFC. Numerical simulation results in IEEE-RTS79 system illustrate that wind power is maximum scheduled with the optimal deployment and operation of DPFC, which confirms the applicability and effectiveness of the proposed method.

3 November 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jia NingJia Ning
Jia Ning
YTYi Tang
Yi Tang
Bingtuan GaoBingtuan Gao
Bingtuan Gao
The uncertainty of wind power results in wind power forecasting errors (WPFE) which lead to difficulties in formulating dispatching strategies to maintain the power balance. Demand response (DR) is a promising tool to balance power by alleviating the impact of WPFE. This paper offers a control method of combining DR and automatic generation control (AGC) units to smooth the system’s imbalance, considering the real-time DR potential (DRP) and security constraints. A schematic diagram is proposed from the perspective of a dispatching center that manages smart appliances including air conditioner (AC), water heater (WH), electric vehicle (EV) loads, and AGC units to maximize the wind accommodation. The presented model schedules the AC, WH, and EV loads without compromising the consumers’ comfort preferences. Meanwhile, the ramp constraint of generators and power flow transmission constraint are considered to guarantee the safety and stability of the power system. To demonstrate the performance of the proposed approach, simulations are performed in an IEEE 24-node system. The results indicate that considerable benefits can be realized by coordinating the DR and AGC units to mitigate the WPFE impacts.