Due to decoupling between mechanical part and electrical part of doubly fed induction generator (DFIG), the DFIG has no natural frequency response capability, which results in decreasing of total rotary inertia of power grid, and the frequency stability of power grid will face larger challenges. This study proposes an assessment method of equivalent inertia time constant, further gives the assessment value of equivalent inertia time constant of DFIG. Then, a virtual inertia optimisation control of DFIG using rotor current direct control based on status assessment value is proposed, which includes conventional function, status assessment and additional virtual inertia control. The assessment values of equivalent inertia time constant of wind farms, synchronous generator and power grid connected with multi‐type generators are calculated, which are related to penetration of wind power and control strategies. The simulation results verify the efficacious of the proposed virtual inertia optimisation control and the accuracy of assessment method of equivalent inertia time constant, and the frequency stability of power grid is improved in the condition of different active power of wind farms and penetration of wind power.
2 December 2016 in Journal of Modern Power Systems and Clean Energy
Wind power in China has experienced fast development in recent years. However, areas rich in wind power resources are often far away from loads centers, which leads to weak connection between wind turbines and power grid. When a grid fault occurs, new transient characteristics in weak grid integrated with doubly-fed induction generators (DFIGs) may present, such as voltage phase angle jump. Current control strategies for wind turbine with strong grid connection are hard to be adapted under weak gird connection. This paper explores the transient characteristics of DFIGs under voltage phase angle jump through analyzing the operation and control characteristics of DFIGs connected into weak grid when the voltage phase angle jumps. Fault ride through (FRT) control strategy of DFIGs based on adaptive phase-locked loop is proposed to adapt weak grid condition. The reference frame of the proposed strategy will be changed in real-time to track the operation condition of DFIGs according to the terminal voltage, and different phase tracking method is adopted during the grid fault. Field data analysis and time domain simulation are carried out. The results show that voltage phase angle jumps when a grid fault occurs, which weakens the FRT capability of DFIGs, and the proposed FRT control strategy can optimize transient characteristics of DFIGs, and improve the FRT capability of DFIGs.
18 February 2016 in Journal of Modern Power Systems and Clean Energy
In the condition of connecting large scale doubly-fed induction generators (DFIGs) into weak grid, the closely coupled interactions between wind generators and power grid becomes more severe. Some new fault characteristics including voltage phase angle jump will emerge, which will influence the power quality of power system. However, there are very few studies focusing on the mechanism of voltage phase angle jump under grid fault in a weak grid with wind turbine integration. This paper focuses on the scientific issues and carries out mechanism studies from different aspects, including mathematical deduction, field data analysis and time domain simulation. Based on the analysis of transient characteristics of DFIGs during the grid fault, this paper points out that the change of terminal voltage phase angle in DFIGs is an electromagnetism transition process, which is different from conventional synchronous generator. Moreover, the impact on transient characteristics of voltage phase angle are revealed in terms of fault ride through (FRT) control strategies, control parameters of current inner-loop of rotor-side converter and grid strength.
With increasing penetration of wind power into the power system, wind power participation in frequency regulation is regarded as a beneficial strategy to improve the dynamic frequency response characteristics of power systems. The traditional power system frequency response (SFR) model, which only includes synchronous generators, is no longer suitable for power systems with high penetrated wind power. An extended SFR model, based on the reduced-order model of wind turbine generator (WTG) and the traditional SFR model, is presented in this paper. In the extended SFR model, the reduced-order model of WTG with combined frequency control is deduced by employing small signal analysis theory. Afterwards, the stability analysis of a closed-loop control system for the extended SFR model is carried out. Time-domain simulations using a test system are performed to validate the effectiveness of the extended SFR model; this model can provide a simpler, clearer and faster way to analyze the dynamic frequency response characteristic for a high-wind integrated power systems. The impact of additional frequency control parameters and wind speed disturbances on the system dynamic frequency response characteristics are investigated.
1 May 2019 in CSEE Journal of Power and Energy Systems
The proportion of installed wind power capacity in power grid continues to increase, which makes the coupled interaction between wind generators and power grid becomes more severe, then the operation characteristics of power grid during grid disturbance may change, especially in the weak grid. There may be dynamic stability issues in a weak grid connection of large‐scale doubly fed induction generator (DFIG)‐based wind turbines. To study the operation characteristics and control problem of the power grid formed by the interconnection of the asynchronous power source based on power electronics equipment, a sensitivity analysis method based on interaction is adopted considering the conventional method cannot consider correctly the physical response of electrical components under a quasi‐steady‐state time‐scale. Then the interaction stability mechanism between the DFIG‐based wind turbine and wind power integration system and its influence factors are deduced. Finally, the influence of power disturbance and short circuit fault on the stability of the large‐scale DFIG‐based wind turbine integration system is analysed with the simulation results.