Today, in the railway sector there is considerable interest in studying the best ways of exploiting train braking energy, in order to achieve a reduction in energy costs and better stabilisation of grid voltage. Among the various on‐board or wayside measures proposed, one of the most promising solutions is based on using wayside energy storage systems (WESSs). A WESS is a storage installation which can be integrated into mass transit systems in urban areas as well as into long‐distance railway lines. It can operate as a smart storage system able to provide relevant benefits in terms of recovering surplus regeneration braking energy, voltage stabilisation, reduction of peak power demand. For these purposes, an effective and flexible simulator is essential to provide all the elements needed to focus and compare feasible configurations and operations. This study examines the problem of introducing the WESS technology in real railway infrastructure. It proposes a method based on a simulator of the WESS system integrated into the infrastructure and carries out the results of dynamic simulations referring to real operating data of the system and vehicles. The results highlight the performance of the WESS in terms of energy and power exchange, also discussing economic aspects.
1 June 2018 in IET Electrical Systems in Transportation
This study focuses on the topic of energy efficiency for railway application. A case study extrapolated from a real system was approached. An entire railway infrastructure, constituted by an alternating current (AC) primary grid, a direct current (DC) railway system and some AC/DC railway electrical substations (ESSs), was observed. The considered system was represented to study the operation of the railway infrastructure in terms of energy. A method, based on an AC/DC power flow approach, was formulated to calculate the efficiency in the use of electrical energy, during the motion of a fleet of trains. The method reports the solution vector (i.e. the AC and DC voltages and currents) as a function of the scheduling of the railway service. The results of the numerical simulations focused on the energy amounts at the ESS. The discussion gives evidence to the impact of alternative operating solutions in terms of energy efficiency strategies.
Waveform distortions are an important issue in distribution systems. In particular, the assessment of very wide spectra, that include also components in the 2–150 kHz range, has recently become an issue of great interest. This is due to the increasing presence of high-spectral emission devices like end-user devices and distributed generation systems. This study proposed a new sliding-window wavelet-modified estimation of signal parameters by rotational invariance technique (ESPRIT) method, particularly suitable for the spectral analysis of waveforms that have very wide spectra. The method is very accurate and requires reduced computational effort. It can be applied successfully to detect spectral components in the range of 0–150 kHz introduced both by distributed power plants, such as wind and photovoltaic generation systems, and by end-user equipment connected to grids through static converters, such as fluorescent lamps.
The widespread use of power electronics converters, e.g., to interface renewable generation systems with the grid or to supply some high-efficiency loads, has caused increased levels of waveform distortions in the modern distribution system. Voltage and current waveforms include spectral components from 0 kHz to 150 kHz, characterized by a non-uniform time-frequency behavior. This wide interval of frequencies is currently divided into “low-frequency” (from 0 kHz to 2 kHz) and “high-frequency” (from 2 kHz to 150 kHz). While the low-frequencies have been exhaustively investigated in the relevant literature and are covered by adequate standardization, studies for the high-frequencies have been addressed only in the last decade to fill current regulatory gaps. In this paper, new power quality (PQ) indices for the assessment of waveform distortions from 0 kHz to 150 kHz are proposed. Specifically, some currently available indices have been properly modified in order to extend their application also to wide-spectrum waveforms. In the particular case of waveform distortions due to renewable generation, numerical applications prove that the proposed indices are useful tools for the characterization of problems (e.g., overheating, equipment malfunctioning, losses due to skin effects, hysteresis losses or eddy current losses) in cases of both low-frequency and high-frequency distortions.
Fluorescent lamps are among the most diffuse electrical components that introduce significant waveform distortions in low voltage distribution systems. These distortions involve a wide range of frequencies (i.e., from 0 kHz to 150 kHz), and spectral components characterized by a non-uniform behavior in time and frequency domains. Early IEC standards covered formally only the range from 0 kHz to 9 kHz, defining grouping and group total harmonic distortion both for the low-frequencies (i.e., from 0 kHz to 2 kHz) and for frequencies ranging from 2 kHz to 9 kHz. Recently, the IEC standards have suggested to extend the grouping, previously defined for the range from 2 kHz to 9 kHz, also to the range from 9 kHz to 150 kHz. In this paper, the waveform distortions of a variable number of fluorescent lamps were quantified by applying the main Power Quality indices currently available for such devices. Indices are evaluated using both the IEC method and an hybrid method proposed recently in the relevant literature, i.e., the sliding-window Wavelet-Modified ESPRIT method. Numerical applications on measured data show the waveform distortion levels versus the number of lamps, quantifying also the different performances of the aforesaid spectral analysis methods.