Anders Larsson

Dr. Anders Larsson


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TBTatiano Busatto
Tatiano Busatto
ALAnders Larsson
Anders Larsson
SRSarah Rönnberg
Sarah Rönnberg
MBMath Bollen
Math Bollen
A method is proposed in this paper to determine the harmonic impedances in low-voltage networks in a stochastic way. The consequences of resonances for harmonic propagation and stability of power converters are summarized. By using Monte Carlo simulation, the method includes the uncertainties in customer impedances, specifically due to electronic loads and local generation. The uncertainty in customer impedance is included by considering probability distribution for the resistive, inductive and capacitive parts of the impedance. The concept of transfer impedance is used for phase-to-neutral connections. A method is developed and applied to two existing low-voltage networks in Sweden. Results show that, for these two networks, the resonant frequencies decrease around 28 % once PV panels are installed. The paper includes a discussion of some of the practical aspects of applying the proposed method.

14 January 2017 in Energies
Verified
Journal Article
Open access
PDF file
LALuisa Alfieri
Luisa Alfieri
Antonio BracaleAntonio Bracale
Antonio Bracale
Guido CarpinelliGuido Carpinelli
Guido Carpinelli
ALAnders Larsson
Anders Larsson
Waveform distortions are an important issue in distribution systems. In particular, the assessment of very wide spectra, that include also components in the 2–150 kHz range, has recently become an issue of great interest. This is due to the increasing presence of high-spectral emission devices like end-user devices and distributed generation systems. This study proposed a new sliding-window wavelet-modified estimation of signal parameters by rotational invariance technique (ESPRIT) method, particularly suitable for the spectral analysis of waveforms that have very wide spectra. The method is very accurate and requires reduced computational effort. It can be applied successfully to detect spectral components in the range of 0–150 kHz introduced both by distributed power plants, such as wind and photovoltaic generation systems, and by end-user equipment connected to grids through static converters, such as fluorescent lamps.

17 October 2017 in Energies
Verified
Journal Article
Open access
PDF file
LALuisa Alfieri
Luisa Alfieri
Antonio BracaleAntonio Bracale
Antonio Bracale
ALAnders Larsson
Anders Larsson
The widespread use of power electronics converters, e.g., to interface renewable generation systems with the grid or to supply some high-efficiency loads, has caused increased levels of waveform distortions in the modern distribution system. Voltage and current waveforms include spectral components from 0 kHz to 150 kHz, characterized by a non-uniform time-frequency behavior. This wide interval of frequencies is currently divided into “low-frequency” (from 0 kHz to 2 kHz) and “high-frequency” (from 2 kHz to 150 kHz). While the low-frequencies have been exhaustively investigated in the relevant literature and are covered by adequate standardization, studies for the high-frequencies have been addressed only in the last decade to fill current regulatory gaps. In this paper, new power quality (PQ) indices for the assessment of waveform distortions from 0 kHz to 150 kHz are proposed. Specifically, some currently available indices have been properly modified in order to extend their application also to wide-spectrum waveforms. In the particular case of waveform distortions due to renewable generation, numerical applications prove that the proposed indices are useful tools for the characterization of problems (e.g., overheating, equipment malfunctioning, losses due to skin effects, hysteresis losses or eddy current losses) in cases of both low-frequency and high-frequency distortions.

1 January 2016 in IFAC-PapersOnLine
Verified
Journal Article
Open access
Lars ErikssonLars Eriksson
Lars Eriksson
ALAnders Larsson
Anders Larsson
ATAndreas Thomasson
Andreas Thomasson

3 March 2003 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
PDF file
AFAxel Franke
Axel Franke
RRRaymond Reinmann
Raymond Reinmann
ALAnders Larsson
Anders Larsson
The effect of the electrodes on the early signal of the ionization sensor has been studied experimentally and with a model for the sensor. Experiments in a constant-volume combustion chamber with a generic electrode configuration allowed to investigate the role of electrode contact and the main path

1 April 1999 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ALAnders Larsson
Anders Larsson
VSV. Scuka
V. Scuka
KBK. Borgeest
K. Borgeest
JHJ. Luiken ter Haseborg
J. Luiken ter Haseborg