Cement provides zonal isolation and mechanical support, and its integrity is critical to the safety and efficiency of the CO2 injection process for geologic carbon storage. This work focuses on interfacial debonding at wellbore interfaces and radial cracking in cement during CO2 injection. It adopts the definition of the energy release rate (ERR) to characterize the propagation of cracks. Based on the finite element method, the proposed model estimates the ERRs of both types of cracks with practical wellbore configurations and injection parameters. Further parametric studies reveal the effects of cement’s mechanical and thermal properties and the crack geometry on crack propagation. Simulation results show that the ERRs of interfacial and radial cracks would surpass 100 J/m2 with typical cement properties. The cement’s thermal expansion coefficient is the most influential factor on the ERR, followed by its Young’s modulus, Poisson’s ratio, and thermal conductivity. The initial sizes and positions of the cracks are also important parameters for controlling crack propagation. Moreover, non-uniform in situ stresses would accelerate crack propagation at the interfaces. These findings are valuable and could help to optimize cement sheath design in order to ensure the long-term integrity of wells for geological carbon storage.
Mixed-mode cooling can effectively reduce the energy consumption of building cooling while satisfying the thermal comfort of occupancy and indoor air quality requirements. This paper predicted the thermal performance and energy-saving potential of an existing Beijing office building (in continental climates) operated in a mixed-mode from April to October. For the natural ventilation mode, the results predicted by simulation were validated with the results of experiments conducted in October 2021 and April 2022. Occupancy thermal comfort of the mixed-mode building was predicted using Predicted Mean Vote (PMV) and adaptive comfort models. The predictions demonstrated acceptable satisfactory thermal comfort for the occupancy. The results showed that the mixed-mode building’s annual cooling energy use is reduced by around 45% compared to the air-conditioned building. In addition, the building’s indoor temperature and velocity distributions were predicted using a Computational Fluid Dynamics (CFD) simulation. The validation showed a satisfactory agreement between CFD simulation and measurement data. It is found from CFD results that cross-ventilation can provide thermal comfort for the occupancy while improving fresh air requirements. The suggested that operational strategies of mixed-mode cooling can be used in office buildings in continental climates. Retrofitting the existing office building can bring a significant amount of energy saving.
With the increasing number of public buildings worldwide, their energy consumption has garnered significant attention. This study aims to promote building energy efficiency and emission reduction by exploring the application of Building-Integrated Photovoltaic technology in library retrofitting. Using a library in Changsha City as a case study, we conducted an energy consumption analysis of the building’s envelope and identified the window section as the highest energy consumer. We proposed a novel improvement scheme—the sun-shading photovoltaic panel (which shades the sun while generating electricity). Additionally, we utilized the roof space for the installation of conventional photovoltaic panels. Simultaneously, the primary objective of this paper was to derive a renovation strategy for public buildings in regions characterized by high summer temperatures and low winter temperatures based on the renovation case of this library. This paper comprehensively investigates the length and angle of sun-shading photovoltaic panels facing different directions, as well as the azimuth angle, tilt angle, and installation spacing of the conventional photovoltaic panels on the roof. Two retrofitting schemes were proposed. Through simulation and comparison, the second scheme was found to reduce the annual electricity consumption by 1,233,354 kWh, achieving a 35.4% decrease compared to the original building. Using the Changsha library as a template for public buildings, this study provided a retrofitting approach with Building-Integrated Photovoltaic technology via DesignBuilder, which could be extended to other geographic locations. The results demonstrated the significant energy-saving effects of the proposed retrofitting scheme.