Assessing corneal biomechanics in vivo has long been a challenge in the field of ophthalmology. Despite recent advances in optical coherence tomography (OCT)-based elastography (OCE) methods, controversy remains regarding the effect of intraocular pressure (IOP) on mechanical wave propagation speed in the cornea. This could be attributed to the complexity of corneal biomechanics and the difficulties associated with conducting in vivo corneal shear-wave OCE measurements. We constructed a simplified artificial eye model with a silicone cornea and controllable IOPs and performed surface wave OCE measurements in radial directions (54–324°) of the silicone cornea at different IOP levels (10–40 mmHg). The results demonstrated increases in wave propagation speeds (mean ± STD) from 6.55 ± 0.09 m/s (10 mmHg) to 9.82 ± 0.19 m/s (40 mmHg), leading to an estimate of Young’s modulus, which increased from 145.23 ± 4.43 kPa to 326.44 ± 13.30 kPa. Our implementation of an artificial eye model highlighted that the impact of IOP on Young’s modulus (ΔE = 165.59 kPa, IOP: 10–40 mmHg) was more significant than the effect of stretching of the silicone cornea (ΔE = 15.79 kPa, relative elongation: 0.98–6.49%). Our study sheds light on the potential advantages of using an artificial eye model to represent the response of the human cornea during OCE measurement and provides valuable insights into the impact of IOP on wave-based OCE measurement for future in vivo corneal biomechanics studies.
Assessing corneal biomechanics in vivo has long been a challenge in the field of ophthalmology. Although recent wave-based optical coherence elastography (OCE) methods have shown promise in this area, the effect of intraocular pressure (IOP) on mechanical wave propagation in the cornea remains unclear. To address this, we constructed an artificial eye model and performed surface wave OCE measurements in the radial directions (54–324°) of the silicone cornea at varying IOP levels (10–40 mmHg). The results demonstrated increases in wave propagation speeds (mean ± STD) from 6.55 ± 0.09 m/s (10 mmHg) to 9.82 ± 0.19 m/s (40 mmHg), leading to an estimate of Young’s modulus, which increased exponentially from 145.23 ± 4.43 kPa to 326.44 ± 13.30 kPa. Our implementation of an artificial eye model highlighted that the impact of IOP on Young’s modulus (ΔE = 165.59 kPa, IOP: 10–40 mmHg) was more significant than the effect of stretching of the silicone cornea (ΔE = 15.79 kPa, relative elongation: 0.98%–6.49%). Our study sheds light on the potential of using an artificial eye model in OCE research for corneal biomechanics. Furthermore, it is critical to consider the impact of IOP on measurement results when utilizing wave-based OCE in clinical settings for enhanced assessment of corneal biomechanics.
Optical coherence tomography (OCT) is a fast, noninvasive, high-resolution optical imaging technique for cross-sectional and volumetric imaging by detecting the interferometric signal to measure the echo delay of backscattered light. Since its first introduction by Huang et al.,1 it has become an indispensable imaging tool for diagnosing and evaluating many eye diseases in the field of ophthalmology.2–5 In recent years, research in dermatology and cardiovascular fields has also received increasing attention.6–9 With the development of OCT technology in recent decades, various functional imaging methods, such as optical coherence tomography angiography (OCTA), polarization-sensitive OCT (PS-OCT), and optical coherence elastography, have been gradually developed.10–15 Among them, OCTA is a microvascular imaging tool with three-dimensional visualization and high spatial resolution that does not require exogenous contrast agents. The blood flow image is obtained by capturing the dynamic signal among multiple scans at the same imaging position. This functional imaging modality has been widely used in preclinical procedures and clinical diagnoses. Several algorithms can be used for OCTA to extract blood flow signals, such as the phase-based variance method,16 the split-spectrum amplitude-decorrelation angiography method,17 and the complex-based optical micro-angiography (OMAG) method.18 However, the functional imaging modality of OCTA suffers from random fluctuations of noise and speckles inherent in the imaging system.19 These undesirable artifacts can generate a false appearance of blood flow and may lead to incorrect interpretation and quantification of OCTA images.
The retinal nerve fiber layer (RNFL) evaluation is becoming a very effective method for the clinical diagnosis of early glaucoma. The purpose of this paper is to extract the pulsations of the RNFL, which might be used as a novel biomarker for glaucoma diagnosis. To demonstrate that the optical coherence tomography (OCT) could extract the subtle RNFL dynamic pulsatile motion in normal eyes in vivo, the subjects’ retina was imaged by spectral domain optical coherence tomography (SD-OCT) based on histogram RNFL pulse extraction algorithm. Firstly, B-scan images of multiple retinal layers in normal subjects were acquired. The RNFL was identified from each B-scan with a segmentation algorithm based on shortest path and convolutional neural network. Secondly, a histogram-based RNFL pulsation extraction algorithm was proposed to track the displacement of the RNFL which is based on the acquired RNFL B-scan images. Finally, in evaluating the dynamic pulse signal extracted from the pulsating motion of RNFL, an experiment was designed to collect heart rate using an infrared pulse sensor device. The cardiac pulse waveform and the RNFL pulse waveform were compared and analyzed in time and frequency domain. The results show that the extracted RNFL pulse has the same frequency as the cardiac pulse, which validate the feasibility and accuracy of the in vivo extraction scheme used in this paper.
A pulsation measurement algorithm was presented in this study, by using the phase-based method to visualize ocular pulse in the anterior chamber of healthy eyes. The algorithm mainly tracks the relative displacement between the cornea and lens by extracting the phase difference between adjacent images separated by 5 ms time intervals. The anterior chamber structural image in vivo is achieved by full-range, complex spectral domain, optical coherence tomography (FRC SD-OCT). Phase tracking was performed on a total of 1000 images within 5 s. In order to eliminate the noise phase caused by human motion during the acquisition process, the high-order phase compensation algorithm was used to eliminate the phase motion of large tissues. The frequency of the phase change in the relative motion after the noise subtraction was 1.2 Hz. Comparing with the heart beat measured by a finger pulse oximeter at the same time, the frequency of the phase change was consistent with the heart beat frequency. This measurement technique can be used to evaluate the biomechanical properties of ocular tissue and has a positive effect on the pathological studies of glaucoma.