Jingjiang Xu

Dr. Jingjiang Xu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
SSShaozhen Song
Shaozhen Song
KZKanheng Zhou
Kanheng Zhou
JXJingjiang Xu
Jingjiang Xu
QZQinqin Zhang
Qinqin Zhang
SLShuyuan Lyu
Shuyuan Lyu
Ruikang WangRuikang Wang
Ruikang Wang
We report a novel design and operation of a highly integrated miniature handheld OCT probe, with high-speed angiography function that can be used in clinical settings for young children and infants, providing rapid, non-invasive structural and angiographic imaging of the retina and choroid. The imaging system is operated at 200 kHz, with 3D OCT and OCTA scan time of 0.8 and 3.2 seconds, respectively, and the scanning angle on the pupil is ± 36°, covering the full perifoveal region. Operator assisting features of the direct-view iris camera and on-probe display are integrated into the hand-held probe, and the fixation target can display animations to attract the attention of young subjects. Compared to conventional OCT systems, the high-speed hand-held OCT system significantly improves the operator’s experience and scanning efficiency, which is important for imaging infants. Imaging results indicate a significant reduction in total time consumption in pediatric ophthalmic imaging sessions, as well as the image quality of OCT angiography.

19 December 2017 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JXJingjiang Xu
Jingjiang Xu
SSShaozhen Song
Shaozhen Song
YLYuandong Li
Yuandong Li
Ruikang WangRuikang Wang
Ruikang Wang
Optical coherence tomography angiography (OCTA) is increasingly becoming a popular inspection tool for biomedical imaging applications. By exploring the amplitude, phase and complex information available in OCT signals, numerous algorithms have been proposed that contrast functional vessel networks within microcirculatory tissue beds. However, it is not clear which algorithm delivers optimal imaging performance. Here, we investigate systematically how amplitude and phase information have an impact on the OCTA imaging performance, to establish the relationship of amplitude and phase stability with OCT signal-to-noise ratio (SNR), time interval and particle dynamics. With either repeated A-scan or repeated B-scan imaging protocols, the amplitude noise increases with the increase of OCT SNR; however, the phase noise does the opposite, i.e. it increases with the decrease of OCT SNR. Coupled with experimental measurements, we utilize a simple Monte Carlo (MC) model to simulate the performance of amplitude-, phase- and complex-based algorithms for OCTA imaging, the results of which suggest that complex-based algorithms deliver the best performance when the phase noise is < ~40 mrad. We also conduct a series of in vivo vascular imaging in animal models and human retina to verify the findings from the MC model through assessing the OCTA performance metrics of vessel connectivity, image SNR and contrast–to–noise ratio. We show that for all the metrics assessed, the complex-based algorithm delivers better performance than either the amplitude- or phase–based algorithms for both the repeated A-scan and the B-scan imaging protocols, which agrees well with the conclusion drawn from the MC simulations.

15 July 2023 in Journal of Biophotonics
Verified
Journal Article
Closed access
JXJingjiang Xu
Jingjiang Xu
XYXing Yuan
Xing Yuan
YHYanping Huang
Yanping Huang
JQJia Qin
Jia Qin
GLGongpu Lan
Gongpu Lan
XWXunbin Wei
Xunbin Wei

10 June 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
JXJingjiang Xu
Jingjiang Xu
MZMingtao Zhu
Mingtao Zhu
PTPeijun Tang
Peijun Tang
JLJunyun Li
Junyun Li
KGKai Gao
Kai Gao
BYBo Yu
Bo Yu
Polarization-sensitive optical coherence tomography (PS-OCT) is a functional imaging tool for measuring tissue birefringence characteristics. It has been proposed as a potentially non-invasive technique for evaluating skin burns. However, the PS-OCT modality usually suffers from high system complexity and relatively low tissue-specific contrast, which makes assessing the extent of burns in skin tissue difficult. In this study, we employ an all-fiber-based PS-OCT system with single-state input, which is simple and efficient for skin burn assessment. Multiple parameters, such as phase retardation (PR), degree of polarization uniformity (DOPU), and optical axis orientation, are obtained to extract birefringent features, which are sensitive to subtle changes in structural arrangement and tissue composition. Experiments on ex vivo porcine skins burned at different temperatures were conducted for skin burn investigation. The burned depths estimated by PR and DOPU increase linearly with the burn temperature to a certain extent, which is helpful in classifying skin burn degrees. We also propose an algorithm of image fusion based on principal component analysis (PCA) to enhance tissue contrast for the multi-parameter data of PS-OCT imaging. The results show that the enhanced images generated by the PCA-based image fusion method have higher tissue contrast, compared to the en-face polarization images by traditional mean value projection. The proposed approaches in this study make it possible to assess skin burn severity and distinguish between burned and normal tissues.

24 April 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
CSChengjin Song
Chengjin Song
WHWeichao He
Weichao He
JFJinping Feng
Jinping Feng
MTMichael D. Twa
Michael D. Twa
YHYanping Huang
Yanping Huang
GLGongpu Lan
Gongpu Lan
Microliter air-pulse optical coherence elastography (OCE) has recently been proposed for the characterization of soft-tissue biomechanics using transient, sub-nanometer to micrometer-scale natural frequency oscillations. However, previous studies have not been able to provide real-time air-pulse monitoring during OCE natural frequency measurement, which could lead to inaccurate measurement results due to the unknown excitation spectrum. To address this issue, we introduce a dual-channel air-pulse OCE method, with one channel stimulating the sample and the other being simultaneously measured with a pressure sensor. This allows for more accurate natural frequency characterization using the frequency response function, as proven by a comprehensive comparison under different conditions with a diverse range of excitation spectra (from broad to narrow, clean to noisy) as well as a diverse set of sample response spectra. We also demonstrate the capability of the frequency-response analysis in distinguishing samples with different stiffness levels: the dominant natural frequencies increased with agar concentrations (181–359 Hz, concentrations: 1–2%, and maximum displacements: 0.12–0.47 µm) and intraocular pressures (IOPs) for the silicone cornea (333–412 Hz, IOP: 5–40 mmHg, and maximum displacements: 0.41–0.52 µm) under a 200 Pa stimulation pressure. These frequencies remained consistent across different air-pulse durations (3 ms to 35 ms). The dual-channel OCE approach that uses transient, low-pressure stimulation and high-resolution imaging holds the potential to advance our understanding of sample frequency responses, especially when investigating delicate tissues such as the human cornea in vivo.

13 September 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
CSChengjin Song
Chengjin Song
WHWeichao He
Weichao He
PSPengfei Song
Pengfei Song
JFJinping Feng
Jinping Feng
YHYanping Huang
Yanping Huang
GLGongpu Lan
Gongpu Lan
Optical coherence elastography (OCE) has recently been used to characterize the natural frequencies of delicate tissues (e.g., the in vivo human cornea) with sub-micron tissue oscillation magnitudes. Here, we investigate broadband spectrum sample stimulation using a contact-based piezoelectric transducer (PZT) chirp excitation and compare its performance with a non-contact, air-pulse excitation for OCE measurements on 1.0-7.5% agar phantoms and an ex vivo porcine cornea under intraocular pressures (IOPs) of 5-40 mmHg. The 3-ms duration air-pulse generated a ∼0–840 Hz excitation spectrum, effectively quantifying the first-order natural frequencies in softer samples (e.g., 1.0%–4.0% agar: 239–782 Hz, 198 Hz/%; porcine cornea: 68–414 Hz, 18 Hz/mmHg, IOP: 5–25 mmHg), but displayed limitations in measuring natural frequencies for stiffer samples (e.g., 4.5%–7.5% agar, porcine cornea: IOP ≥ 30 mmHg) or higher order natural frequency components. In contrast, the chirp excitation produced a much wider spectrum (e.g., 0–5000 Hz), enabling the quantification of both first-order natural frequencies (1.0%–7.5% agar: 253–1429 Hz, 181 Hz/%; porcine cornea: 76–1240 Hz, 32 Hz/mmHg, IOP: 5–40 mmHg) and higher order natural frequencies. A modified Bland-Altman analysis (mean versus relative difference in natural frequency) showed a bias of 20.4%, attributed to the additional mass and frequency introduced by the contact nature of the PZT probe. These findings, especially the advantages and limitations of both excitation methods, can be utilized to validate the potential application of natural frequency OCE, paving the way for the ongoing development of biomechanical characterization methods utilizing sub-micron tissue oscillation features.