Background: Interpretation of the complete blood count (CBC) parameters requires reliable biological variation (BV) data. The aims of this study were to appraise the quality of publications reporting BV data for CBC parameters by applying the BV Data Critical Appraisal Checklist (BIVAC) and to deliver global BV estimates based on BIVAC compliant studies.Methods: Relevant publications were identified by a systematic literature search and evaluated for their compliance with the 14 BIVAC criteria, scored as A, B, C or D, indicating decreasing compliance. Global CVIand CVGestimates with 95% CI were delivered by a meta-analysis approach using data from BIVAC compliant papers (grades A–C).Results: In total, 32 studies were identified; four received a BIVAC grade A, 2 B, 20 C and 6 D. Meta-analysis derived CVIand CVGestimates were generally lower or in line with those published in a historical BV database available online. Except for reticulocytes, CVIestimates of erythrocyte related parameters were below 3%, whereas platelet (except MPV and PDW) and leukocyte related parameters ranged from 5% to 15%.Conclusions: A systematic review of CBC parameters has provided updated, global estimates of CVIand CVGthat will be included in the newly published European Federation of Clinical Chemistry and Laboratory Medicine BV Database.
Reference intervals are commonly used as a decision-making tool. In this review, we provide an overview on “big data” and reference intervals, describing the rationale, current practices including statistical methods, essential prerequisites concerning data quality, including harmonization and standardization, and future perspectives of the indirect determination of reference intervals using routine laboratory data.
Introduction: Standardization is the ability to obtain interchangeable results leading to same medical interpretation. External quality assessment (EQA) is the main support of the on-going harmonization initiatives. Aim of study was to evaluate results obtained from two years category 1 EQA program experience in Spain and determine the impact of applying this type of EQA program on the analytical standardization. Materials and methods: According to the analytical method, traceability and instrument different groups were established which results were evaluated by calculating mean, coefficient of variation and percent of deviation to the reference value. Analytical performance specifications used to the results' evaluation were derived from biological variation for bias and from the inter-laboratory coefficients of variation found in a previous pilot study. Results: Only creatinine measured by enzymatic methods gave excellent results, although few laboratories used this method. Creatine kinase and GGT gave good precision and bias in all, but one instrument studied. For the remaining analytes (ALT, ALP, AST, bilirubin, calcium, chloride, glucose, magnesium, potassium, sodium, total protein and urate) some improvement is still necessary to achieve satisfactory standardization in our setting. Conclusions: The two years of category 1 EQA program experience in Spain have manifested a lack of standardization of 17 most frequent biochemistry tests used in our laboratories. The impact of the information obtained on the lack of standardization is to recommend abandoning methods such as ALT, AST without exogenous pyridoxal phosphate, Jaffe method for creatinine, and do not use non-commutable calibrators, such as aqueous solutions for calcium and sodium.