Luisa María Martínez Sánchez

Luisa María Martínez Sánchez

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SCSara Ciucci
Sara Ciucci
YGYan Ge
Yan Ge
CDClaudio Durán
Claudio Durán
APAlessandra Palladini
Alessandra Palladini
Víctor Jiménez-JiménezVíctor Jiménez-Jiménez
Víctor Jiménez-Jiménez
Carlo Vittorio CannistraciCarlo Vittorio Cannistraci
Carlo Vittorio Cannistraci
Omic science is rapidly growing and one of the most employed techniques to explore differential patterns in omic datasets is principal component analysis (PCA). However, a method to enlighten the network of omic features that mostly contribute to the sample separation obtained by PCA is missing. An alternative is to build correlation networks between univariately-selected significant omic features, but this neglects the multivariate unsupervised feature compression responsible for the PCA sample segregation. Biologists and medical researchers often prefer effective methods that offer an immediate interpretation to complicated algorithms that in principle promise an improvement but in practice are difficult to be applied and interpreted. Here we present PC-corr: a simple algorithm that associates to any PCA segregation a discriminative network of features. Such network can be inspected in search of functional modules useful in the definition of combinatorial and multiscale biomarkers from multifaceted omic data in systems and precision biomedicine. We offer proofs of PC-corr efficacy on lipidomic, metagenomic, developmental genomic, population genetic, cancer promoteromic and cancer stem-cell mechanomic data. Finally, PC-corr is a general functional network inference approach that can be easily adopted for big data exploration in computer science and analysis of complex systems in physics.

7 August 2020 in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
Verified
Journal Article
Open access
PDF file
LSLuisa María Martínez Sánchez
Luisa María Martínez Sánchez
FMFernando Marqués-García
Fernando Marqués-García
YOYesim Ozarda
Yesim Ozarda
ABAlbert Blanco
Albert Blanco
NBNannette Brouwer
Nannette Brouwer
WEWendy Den Elzen
Wendy Den Elzen
Reference intervals are commonly used as a decision-making tool. In this review, we provide an overview on “big data” and reference intervals, describing the rationale, current practices including statistical methods, essential prerequisites concerning data quality, including harmonization and standardization, and future perspectives of the indirect determination of reference intervals using routine laboratory data.

19 May 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LSLuisa María Martínez Sánchez
Luisa María Martínez Sánchez
CCChrista M. Cobbaert
Christa M. Cobbaert
RNRaymond Noordam
Raymond Noordam
NBNannette Brouwer
Nannette Brouwer
ABAlbert Blanco-Grau
Albert Blanco-Grau
WEWendy P. J. Den Elzen
Wendy P. J. Den Elzen
The aim of this study was to determine reference intervals in an outpatient population from Vall d’Hebron laboratory using an indirect approach previously described in a Dutch population (NUMBER project). We used anonymized test results from individuals visiting general practitioners and analysed during 2018. Analytical quality was assured by EQA performance, daily average monitoring and by assessing longitudinal accuracy between 2018 and 2020 (using trueness verifiers from Dutch EQA). Per test, outliers by biochemically related tests were excluded, data were transformed to a normal distribution (if necessary) and means and standard deviations were calculated, stratified by age and sex. In addition, the reference limit estimator method was also used to calculate reference intervals using the same dataset. Finally, for standardized tests reference intervals obtained were compared with the published NUMBER results. Reference intervals were calculated using data from 509,408 clinical requests. For biochemical tests following a normal distribution, similar reference intervals were found between Vall d’Hebron and the Dutch study. For creatinine and urea, reference intervals increased with age in both populations. The upper limits of Gamma-glutamyl transferase were markedly higher in the Dutch study compared to Vall d’Hebron results. Creatine kinase and uric acid reference intervals were higher in both populations compared to conventional reference intervals. Medical test results following a normal distribution showed comparable and consistent reference intervals between studies. Therefore a simple indirect method is a feasible and cost-efficient approach for calculating reference intervals. Yet, for generating standardized calculated reference intervals that are traceable to higher order materials and methods, efforts should also focus on test standardization and bias assessment using commutable trueness verifiers.

18 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JCJuan Cosín-Sales
Juan Cosín-Sales
MAManuel Anguita
Manuel Anguita
CSCarmen Suárez
Carmen Suárez
CACarlos Arias-Cabrales
Carlos Arias-Cabrales
LSLuisa María Martínez Sánchez
Luisa María Martínez Sánchez
SCSusana Fernández de Cabo
Susana Fernández de Cabo
Background/Objectives: We assessed the effectiveness and safety of vitamin K antagonists (VKAs) versus direct oral anticoagulants (DOACs) in patients with atrial fibrillation (AF) using artificial intelligence techniques. Methods: This is a retrospective study in 15 Spanish hospitals (2014–2020), including adult AF patients with no history of anticoagulation, thrombosis events, rheumatic mitral valvular heart disease, mitral valve stenosis, or pregnancy. We employed EHRead® technology based on natural language processing (NLP) and machine learning (ML), along with SNOMED-CT terminology, to extract clinical data from electronic health records (EHRs). Using propensity score matching (PSM), the effectiveness, safety, and hospital mortality of VKAs versus DOACs were analyzed through Kaplan–Meier curves and Cox regression. Results: Out of 138,773,332 EHRs from 4.6 million individuals evaluated, 44,292 patients were included, 79.6% on VKAs and 20.4% on DOACs. Most patients were elderly [VKA 78 (70, 84) and DOAC 75 (66, 83) years], with numerous comorbidities (75.5% and 70.2% hypertension, 47.2% and 39.9% diabetes, and 40.3% and 34.8% heart failure, respectively). Additionally, 60.4% of VKA and 48.7% of DOAC users had a CHA2DS2-VASc Score ≥4. After PSM, 8929 patients per subgroup were selected. DOAC users showed a lower risk of thrombotic events [HR 0.81 (95% CI 0.70–0.94)], minor bleeding [HR 0.89 (95% CI 0.83–0.96)], and mortality [HR 0.80 (95% CI 0.69–0.92)]. Conclusions: Applying NLP and ML, we generated valuable real-world evidence on anticoagulated AF patients in Spain. Even in complex populations, DOACs have demonstrated a better safety and effectiveness profile than VKAs.

8 November 2022 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
LSLuisa María Martínez Sánchez
Luisa María Martínez Sánchez
PGPablo Gabriel-Medina
Pablo Gabriel-Medina
YVYolanda Villena-Ortiz
Yolanda Villena-Ortiz
AGAlba E. García-Fernández
Alba E. García-Fernández
ABAlbert Blanco-Grau
Albert Blanco-Grau
WEWendy P.J. Den Elzen
Wendy P.J. Den Elzen
Objectives: The aim of this study was to harmonize the criteria for the Bhattacharya indirect method Microsoft Excel Spreadsheet for reference intervals calculation to reduce between-user variability and use these criteria to calculate and evaluate reference intervals for eight analytes in two different years. Methods: Anonymized laboratory test results from outpatients were extracted from January 1st 2018 to December 31st 2019. To assure data quality, we examined the monthly results from an external quality control program. Reference intervals were determined by the Bhattacharya method with the St Vincent’s hospital Spreadsheet firstly using original criteria and then using additional harmonized criteria defined in this study. Consensus reference intervals using the additional harmonized criteria were calculated as the mean of four users’ lower and upper reference interval results. To further test the operation criteria and robustness of the obtained reference intervals, an external user validated the Spreadsheet procedure. Results: The extracted test results for all selected laboratory tests fulfilled the quality criteria and were included in the present study. Differences between users in calculated reference intervals were frequent when using the Spreadsheet. Therefore, additional criteria for the Spreadsheet were proposed and applied by independent users, such as: to set central bin as the mean of all the data, bin size as small as possible, at least three consecutive bins and a high proportion of bins within the curve. Conclusions: The proposed criteria contributed to the harmonization of reference interval calculation between users of the Bhattacharya indirect method Spreadsheet.

13 June 2022 in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
Verified
Journal Article
Open access
PDF file
YVYolanda Villena-Ortiz
Yolanda Villena-Ortiz
LCLaura Castellote-Bellés
Laura Castellote-Bellés
LSLuisa María Martínez Sánchez
Luisa María Martínez Sánchez
MBMaría I. Benítez-Carabante
María I. Benítez-Carabante
MMMarta Miarons
Marta Miarons
JLJoan López-Hellín
Joan López-Hellín
Objectives Administration of busulfan is extending rapidly as a part of a conditioning regimen in patients undergoing hematopoietic stem cell transplantation (HSCT). Monitoring blood plasma levels of busulfan is recommended for identifying the optimal dose in patients and for minimizing toxicity. The aim of this research was to validate a simple, rapid, and cost-effective analytical tool for measuring busulfan in human plasma that would be suitable for routine clinical use. This novel tool was based on liquid chromatography coupled to mass spectrometry. Methods Human plasma samples were prepared using a one-step protein precipitation protocol. These samples were then resolved by isocratic elution in a C18 column. The mobile phase consisted 2 mM ammonium acetate and 0.1% formic acid dissolved in a 30:70 ratio of methanol/water. Busulfan-d8 was used as the internal standard. Results The run time was optimized at 1.6 min. Standard curves were linear from 0.03 to 5 mg/L. The coefficient of variation (%CV) was less than 8%. The accuracy of this method had an acceptable bias that fell within 85–115% range. No interference between busulfan and the interfering compound hemoglobin, lipemia, or bilirubin not even at the highest concentrations of compound was tested. Neither carryover nor matrix effects were observed using this method. The area under the plasma drug concentration-time curves obtained for 15 pediatric patients who received busulfan therapy prior to HSCT were analyzed and correlated properly with the administered doses. Conclusions This method was successfully validated and was found to be robust enough for therapeutic drug monitoring in a clinical setting.