Seamus O'Shaughnessy

Dr. Seamus O'Shaughnessy

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Applied Energy
Verified
Journal Article
Closed access
RMR. Merienne
R. Merienne
JLJ. Lynn
J. Lynn
EME. McSweeney
E. McSweeney
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy

11 August 2022 in Applied Materials Today
Verified
Journal Article
Open access
Anirudh SharmaAnirudh Sharma
Anirudh Sharma
SMSaeed Masoumi
Saeed Masoumi
DGDesta Gedefaw
Desta Gedefaw
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
DBDerya Baran
Derya Baran
Amir PakdelAmir Pakdel
Amir Pakdel

1 November 2017 in Applied Energy
Verified
Journal Article
Open access
MDM.J. Deasy
M.J. Deasy
NBN. Baudin
N. Baudin
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
ARA.J. Robinson
A.J. Robinson

1 June 2014 in Energy for Sustainable Development
Verified
Journal Article
Open access
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
MDM.J. Deasy
M.J. Deasy
JDJ.V. Doyle
J.V. Doyle
ARA.J. Robinson
A.J. Robinson

1 September 2022 in Heat and Mass Transfer
Verified
Journal Article
Open access
PDF file
NWN. P. Williams
N. P. Williams
JPJohn Power
John Power
DTD. Trimble
D. Trimble
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
Thermal cycling is known to adversely affect the performance and lifespan of thermoelectric generators (TEGs) yet has received limited attention to date. The current study experimentally investigates the effect of thermal cycling on the performance of twelve nominally identical TEG modules. Six samples were subjected to the same thermal cycle profile with an average heating time of 154 s to examine the variation in their outputs. The maximum cycling temperature was varied between 170 °C and 190 °C for a further six samples to investigate the effect of maximum set-point temperature on performance. Degradation in performance was exhibited by all modules, with maximum power outputs between 28% and 57% of pre-cycling values and a decrease in the dimensionless figure of merit $$ZT$$ ZT of 21% to 56% upon cessation of cycling. Sudden ‘breakdowns’ or significant reductions in output power were observed for all TEGs, accompanied by increased electrical resistance, which is indicative of internal damage to the modules arising from the formation of micro-cracks at the interface between the semiconductor thermocouples and electrically conductive material. The rate of degradation post-‘breakdown’ appeared to be influenced by the maximum set-point temperature, with more rapid decreases observed for increasing temperatures.

1 October 2015 in Energy for Sustainable Development
Verified
Journal Article
Open access
SOSeamus O'Shaughnessy
Seamus O'Shaughnessy
MDM.J. Deasy
M.J. Deasy
JDJ.V. Doyle
J.V. Doyle
ARA.J. Robinson
A.J. Robinson