Csaba Csobay-Novák

Dr. Csaba Csobay-Novák

Heart and Vascular Center, Semmelweis University, Budapest, Hungary
orcid
Interventional radiologist

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ZBZsolt Bagyura
Zsolt Bagyura
LKLoretta Zsuzsa Kiss
Loretta Zsuzsa Kiss
ÁLÁrpád Lux
Árpád Lux
Csaba Csobay-NovákCsaba Csobay-Novák
Csaba Csobay-Novák
ÁJÁdám L. Jermendy
Ádám L. Jermendy
ÉPÉva Pállinger
Éva Pállinger
Several inflammatory biomarkers were found to be associated with an increased risk of cardiovascular disease. Neutrophil-to-lymphocyte ratio (NLR) is a marker of subclinical inflammation that increases with the stress response. Visceral adiposity index (VAI) calculated as a combination of anthropometric and metabolic parameters reflects both the extent and function of visceral adipose tissue. Given the association of subclinical inflammation with both obesity and cardiovascular diseases, it is plausible that the inflammation–CVD association is modulated by the amount and function of adipose tissue. Thus, our aim was to examine the association between NLR and coronary artery calcium score (CACS), an intermediate marker of coronary artery disease in asymptomatic patients across VAI tertiles. Methods: Data from 280 asymptomatic participants of a cardiovascular screening program were analysed. In addition to the collection of lifestyle and medical history, a non-contrast cardiac CT scan and laboratory tests were performed on all participants. Multivariate logistic regression was conducted with CACS > 100 as the outcome and with conventional cardiovascular risk factors and NLR, VAI, and NLR by VAI tertile as predictors. Results: We found an interaction between VAI tertiles and NLR; NLR values were similar in the lower VAI tertiles, while they were higher in the CACS > 100 in the 3rd VAI tertile (CACS ≤ 100: 1.94 ± 0.58 vs. CACS > 100: 2.48 ± 1.1, p = 0.008). According to multivariable logistic regression, the interaction between NLR and VAI tertiles remained: NLR was associated with CACS > 100 in the 3rd VAI tertile (OR = 1.67, 95% CI 1.06–2.62, p = 0.03) but not in the lower tertiles even after adjustment for age, sex, smoking, history of hypertension, hyperlipidaemia, and diabetes mellitus, as well as high-sensitivity C-reactive protein. Our findings draw attention to the independent association between subclinical, chronic, systemic inflammation and subclinical coronary disease in obesity.

1 February 2015 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
Csaba Csobay-NovákCsaba Csobay-Novák
Csaba Csobay-Novák
TBTamas Barany
Tamas Barany
EZEndre Zima
Endre Zima
BNBalázs Nemes
Balázs Nemes
PSPéter Sótonyi
Péter Sótonyi
KHKálmán Hüttl
Kálmán Hüttl
Purpose: To investigate the possible role of stent selection and procedure-related vessel diameter changes in the development of persisting hemodynamic depression (PHD) and to demonstrate the effectiveness and safety of permanent pacemaker implantation in patients with refractory PHD. Methods: Data from 584 procedures performed in 542 patients (398 men; mean age 67.3 years) between 2008 and 2011 using Wallstent, Precise, and Xact stents in a nonrandomized fashion were analyzed retrospectively. Cardiovascular risk factors and lesion, stent, and balloon characteristics were collected, and the pre- and postprocedure diameters of the common carotid artery (CCA) and internal carotid artery were measured. PHD was defined as any episode of hypotension (systolic blood pressure <90 mm Hg) and/or bradycardia (heart rate 6 hours. Risk factors for PHD were sought using logistic regression analyses; the results are presented as the odds ratio (OR) and 95% confidence interval (CI). Results: The incidence of PHD was 37.0% (216/584). Refractory PHD was encountered in 9 patients; among these, 6 were successfully treated with pacemaker implantation. A history of prior ipsilateral carotid endarterectomy (OR 0.44, 95% CI 0.22 to 0.87, p=0.019) and the presence of a contralateral high-grade stenosis (OR 0.12, 95% CI 0.02 to 0.95, p=0.045) were independent protective factors, while calcification (OR 1.5, 95% CI 1.03 to 2.18, p=0.034), involvement of the carotid bulb (OR 2.56, 95% 1.62 to 4.03, p<0.001), and implantation of a nitinol stent (adjusted OR 1.62, 95% CI 1.12 to 2.34, p=0.011) were independent risk factors for developing PHD after carotid artery stenting. The ratio of the post-/preprocedure CCA diameter (p=0.002), the stent to CCA diameter ratio (p=0.009), and the presence of residual stenosis (p=0.009) were significantly higher in the PHD group. Conclusion: Stent selection and procedure-related changes in vessel diameter may have an influence on the development of PHD. Permanent pacemaker implantation is an effective treatment option in patients with refractory PHD.

1 December 2021 in European Journal of Radiology
Verified
Journal Article
Open access
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
ÁJÁdám Levente Jermendy
Ádám Levente Jermendy
FSFerenc Imre Suhai
Ferenc Imre Suhai
APAlexisz Panajotu
Alexisz Panajotu
JCJudit Csőre
Judit Csőre
BSBalint Szilveszter
Balint Szilveszter
Filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) are ubiquitously applied in the reconstruction of coronary CT angiography (CCTA) datasets. However, currently no data is available on the impact of a model-based adaptive filter (MBAF2), recently developed for a dedicated cardiac scanner. Our aim was to determine the effect of MBAF2 on subjective and objective image quality parameters of coronary arteries on CCTA. Images of 102 consecutive patients referred for CCTA were evaluated. Four reconstructions of coronary images (FBP, ASIR, MBAF2, ASIR + MBAF2) were co-registered and cross-section were assessed for qualitative (graininess, sharpness, overall image quality) and quantitative [image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] image quality parameters. Image noise and signal were measured in the aortic root and the left main coronary artery, respectively. Graininess, sharpness, and overall image quality was assessed on a 4-point Likert scale. As compared to FBP, ASIR, and MBAF2, ASIR + MBAF2 resulted in reduced image noise [53.1 ± 12.3, 30.6 ± 8.5, 36.3 ± 4.2, 26.3 ± 4.0 Hounsfield units (HU), respectively; p < 0.001], improved SNR (8.4 ± 2.6, 14.1 ± 3.6, 11.8 ± 2.3, 16.3 ± 3.3 HU, respectively; p < 0.001) and CNR (9.4 ± 2.7, 15.9 ± 4.0, 13.3 ± 2.5, 18.3 ± 3.5 HU, respectively; p < 0.001). No difference in sharpness was observed amongst the reconstructions (p = 0.08). Although ASIR + MBAF2 was non-superior to ASIR regarding overall image quality (p = 0.99), it performed better than FBP (p < 0.001) and MBAF2 (p < 0.001) alone. The combination of ASIR and MBAF2 resulted in reduced image noise and improved SNR and CNR. The implementation of MBAF2 in clinical practice may result in improved noise reduction performance and could potentiate radiation dose reduction.

Verified
Journal Article
Open access
PDF file
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
ÁJÁdám Levente Jermendy
Ádám Levente Jermendy
MKMárton Kolossváry
Márton Kolossváry
BVBorbála Vattay
Borbála Vattay
MBMelinda Boussoussou
Melinda Boussoussou
BSBálint Szilveszter
Bálint Szilveszter
Although reaching target heart rate (HR) before coronary CT angiography (CCTA) is still of importance, adequate HR control remains a challenge for many patients. Purpose-built cardiac scanners may provide optimal image quality at higher HRs by further improving temporal resolution. We aimed to compare the amount of motion artifacts on CCTA acquired using a dedicated cardiac CT (DCCT) compared to a conventional multidetector CT (MDCT) scanner. We compared 80 DCCT images to 80 MDCT scans matched by sex, age, HR, and coronary dominance. Image quality was graded on a per-patient, per-vessel and per-segment basis. Motion artifacts were assessed using Likert scores (1: non-diagnostic, 2: severe artifacts, 3: mild artifacts, 4: no artifacts). Patients were stratified into four groups according to HR (70/min). Overall, 2328 coronary segments were evaluated. DCCT demonstrated superior overall image quality compared to MDCT (3.7 ± 0.4 vs. 3.3 ± 0.7, p < 0.001). DCCT images yielded higher Likert scores in all HR ranges, which was statistically significant in the 60–65/min, 66–70/min and >70/min ranges (3.9 ± 0.2 vs. 3.7 ± 0.2, p = 0.008; 3.5 ± 0.5 vs. 3.1 ± 0.6, p = 0.048 and 3.5 ± 0.4 vs. 2.7 ± 0.7, p < 0.001, respectively). Using a dedicated cardiac scanner results in fewer motion artifacts, which may allow optimal image quality even in cases of high HRs.

23 October 2024 in Journal of Vascular Surgery Cases, Innovations and Techniques
Verified
Journal Article
Open access
Csaba Csobay-NovákCsaba Csobay-Novák
Csaba Csobay-Novák
Bendegúz JuhosBendegúz Juhos
Bendegúz Juhos
ASAndrás Szentiványi
András Szentiványi
ÁBÁkos Bérczi
Ákos Bérczi
AHArtúr Hüttl
Artúr Hüttl
PSPéter Sótonyi
Péter Sótonyi
The physician-modified endograft technique is becoming widely accepted as an alternative to standard fenestrated endovascular aortic repair. We report a streamlined workflow based on a bifurcation endograft, using the punch card and the Hungaroring reinforcement, two novel additions to the armamentarium that might contribute to the safety and durability of such repairs. A cohort of 11 patients was treated with 43 vessels incorporated. The clinical success rate was 100%. No major adverse event or death was recorded at 30 days. The punch card and the novel reinforcement technique might improve the safety and durability of such repairs.

1 December 2015 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
Csaba Csobay-NovákCsaba Csobay-Novák
Csaba Csobay-Novák
DFDaniele Mariastefano Fontanini
Daniele Mariastefano Fontanini
BSBrigitta R. Szilágyi
Brigitta R. Szilágyi
ZSZoltán Szeberin
Zoltán Szeberin
BSBálint A. Szilveszter
Bálint A. Szilveszter
PSPéter Sótonyi
Péter Sótonyi