The high-pressure polyethylene process uses cyclone separators to separate ethylene gas, polyethylene, and its oligomers. The oligomers larger than 10 microns that cannot be separated must be filtered through a filter to prevent them from entering the compressor and affecting its normal operation. When the separation efficiency of the cyclone separator is low, the filter must be cleaned more frequently, which will reduce production efficiency. Research shows that improving the separation efficiency of the separator is beneficial for the separation of small-particle oligomers and reduces the frequency of filter cleaning. For this reason, Computational Fluid Dynamics simulations were performed for 27 sets of cyclone separators to determine the effects of eight structural factors (cylinder diameter, cylinder height, cone diameter, cone height, guide vane height, guide vane angle, exhaust pipe extension length, and umbrella structure height) on separation efficiency and pressure drop. The equations for separation efficiency and pressure drop using these eight factors and the equations based on energy-efficiency parameters were determined. The optimization analysis showed that separation efficiency can be improved by 98.7% under the premise that the pressure drop is only increased by 8.2%. By applying the improved structure to the high-pressure polyethylene process, separation efficiency is increased by 17.7%, which could effectively reduce the frequency of filter cleaning for this process, and thereby greatly improve production efficiency.
Local wall thinning is a common defect on the surface of pipelines, which can cause damage to the pipeline under complex pipeline loads. Based on the study on the limit load of straight pipes with defects, the nonlinear finite element method was used to analyze the limit load of straight pipes with local wall-thinning defects under internal pressure, bending moment, torque, axial force, and their combinations, and the empirical limit-load equations of straight pipes with local wall-thinning defects under single and complex loads were fitted. Based on the allowable load on the equipment nozzles, the influences of torque and axial force on the load-bearing capacity of straight pipes with local wall-thinning defects were quantitatively analyzed. For medium and low-pressure equipment, the load-bearing capacity was reduced by 0.59~1.44% under the influence of torque, and by 0.83~1.80% under the influence of axial force. For high-pressure equipment, the load-bearing capacity was reduced by 10.07~20.90% under the influence of torque, and by 2.01~12.40% under the influence of axial force.