Time-varying elastance models can simulate only the pressure and volume signals in the heart chambers while the diagnosis of clinical cases and evaluation of different treatment techniques require more information. In this study, an extended model utilizing the geometric dimensions of the heart chambers was developed to describe the cardiac function. The new cardiac model was evaluated by simulating a healthy and dilated cardiomyopathy (DCM) condition for adults and children. The left ventricular ejection fraction, end-diastolic volume, end-diastolic diameter and diastolic sphericity index were 53.60%, 125 mL, 5.08 cm and 1.82 in the healthy adult cardiovascular system model and 23.70%, 173 mL, 6.60 cm and 1.40 in the DCM adult cardiovascular system model. In the healthy child cardiovascular system model, the left ventricular ejection fraction, end-diastolic volume, end-diastolic diameter and diastolic sphericity index were 59.70%, 92 mL, 4.10 cm and 2.26 respectively and 30.70%, 125 mL, 4.94 cm and 1.87 in the DCM child cardiovascular system model. The developed cardiovascular system model simulates the hemodynamic variables and clinical diagnostic indicators within the physiological range for healthy and DCM conditions proving the feasibility of this new model to evaluate clinical cases in adults and children.
17 November 2015 in Australasian Physics & Engineering Sciences in Medicine
Continuous flow left ventricular assist devices (CF-LVADs) reduce arterial pulsatility, which may cause long-term complications in the cardiovascular system. The aim of this study is to improve the pulsatility by driving a CF-LVAD at a varying speed, synchronous with the cardiac cycle in an ex-vivo experiment. A Micromed DeBakey pump was used as CF-LVAD. The heart was paced at 140 bpm to obtain a constant cardiac cycle for each heartbeat. First, the CF-LVAD was operated at a constant speed. At varying-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. For synchronization purposes, an algorithm was developed to trigger the CF-LVAD each heartbeat. The pump flow rate was selected as the control variable and a reference model was used for regulating the CF-LVAD speed. Continuous and varying-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility doubled in both arterial pressure and pump flow rate signals under pulsatile pump speed support. This study shows the possibility of improving the pulsatility in CF-LVAD support by regulating pump speed over a cardiac cycle without compromising the overall level of support.
25 June 2016 in Journal of Medical and Biological Engineering
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.
Purpose: Continuous flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which causes a decrease in pulse pressure and pulsatility in the arteries and allegedly may lead to late complications such as aortic insufficiency and gastrointestinal bleeding. The purpose of this study is to increase the arterial pulse pressure and pulsatility while obtaining more physiological hemodynamic signals, by controlling the CF-LVAD flow rate. Methods: A lumped parameter model was used to simulate the cardiovascular system including the heart chambers, heart valves, systemic and pulmonary arteries and veins. A baroreflex model was used to regulate the heart rate and a model of the Micromed DeBakey CF-LVAD (Micromed Technology, Houston, TX, USA) to simulate the pump dynamics at different operating speeds. A model simulating the flow rate through the aortic valve served as reference model. CF-LVAD operating speed was regulated by applying proportional-integral (PI) control to the pump flow rate. For comparison, the CF-LVAD was also operated at a constant speed, equaling the mean CF-LVAD speed as applied in pulsatile mode. Results: In different operating modes, at the same mean operating speeds, mean pump output, mean arterial pressure, end-systolic and end-diastolic volume and heart rate were the same over the cardiac cycle. However, the arterial pulse pressure and index of pulsatility increased by 50% in the pulsatile CF-LVAD support mode with respect to constant speed pump support. Conclusions: This study shows the possibility of obtaining more physiological pulsatile hemodynamics in the arteries by applying output-driven varying speed control to a CF-LVAD.